Amplification-free point of care immunosensor for detecting type V collagen at a concentration level of ng/ml

Point-of-care testing (POCT) is applicable in the immediate vicinity of the patient, where timely diagnosis or prognostic information could help doctors decide the following treatment. Among types of developed POCT, gold nanoparticle based lateral flow strip technology provides advantages such as simple operation, cost-effectiveness, and a user-friendly platform. Therefore, this type of POCT is most likely to be used in battlefields and developing countries. However, conventional lateral flow strips suffer from low detection limits. Although enzyme-linked amplification was demonstrated to improve the detection limit and sensitivity by stronger visible lines or by permitting electrochemical analytical instrumentation, the enzyme labels have potential to cause interference with other enzymes in our body fluids. To eliminate this limitation, we developed an amplification-free gold nanoparticle-based immunosensor applied for detecting collagen type V, which is produced or released abnormally during rejection of lung transplants and sulfur mustard exposure. By using suitable blocking protein to stabilize gold nanoparticles as the reporter probe, a low detection limit of ng/ml was achieved. This strategy is a promising platform for clinical POCT, with potential applications in military or disaster response.

[1]  Axel Warsinke,et al.  Point-of-care testing of proteins , 2009, Analytical and bioanalytical chemistry.

[2]  D. Ring,et al.  Quality of prospective controlled randomized trials. Analysis of trials of treatment for lateral epicondylitis as an example. , 2007, The Journal of bone and joint surgery. American volume.

[3]  O. Velev,et al.  Characterization and optimization of gold nanoparticle-based silver-enhanced immunoassays. , 2007, Analytical chemistry.

[4]  L Orci,et al.  Transforming growth factor beta stimulates collagen-matrix contraction by fibroblasts: implications for wound healing. , 1988, Proceedings of the National Academy of Sciences of the United States of America.

[5]  P. Rice,et al.  Examination of changes in connective tissue macromolecular components of large white pig skin following application of lewisite vapour , 2004, Journal of applied toxicology : JAT.

[6]  Reinhard Renneberg,et al.  Rapid analysis of fatty acid-binding proteins with immunosensors and immunotests for early monitoring of tissue injury. , 2005, Biosensors & bioelectronics.

[7]  Reinhard Renneberg,et al.  New trends in immunoassays. , 2008, Advances in biochemical engineering/biotechnology.

[8]  Rong-Hwa Shyu,et al.  Colloidal gold-based immunochromatographic assay for detection of botulinum neurotoxin type B. , 2004, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[9]  T. Neff,et al.  Attenuation of half sulfur mustard gas‐induced acute lung injury in rats , 2006, Journal of applied toxicology : JAT.

[10]  Gerald N. Smith,et al.  Anti-Type V Collagen Humoral Immunity in Lung Transplant Primary Graft Dysfunction1 , 2008, The Journal of Immunology.