OKAS-3D: optoelectronic jaw movement recording system with six degrees of freedom

OKAS-3D is a further development of the single floating circle target tracker. This tracker consists of a cathode ray tube display, a lens in front of the display and a circular light-sensitive photocell placed in the image field of the lens. A small circular trace generated on the screen is focused around the photocell. The sinusoidal electrical output of the photocell contains all the relevant information regarding the position of the photocell relative to the image of the circular light trace. This gives the tracker the properties of a servo-controller with position feedback. In OKAS-3D three pairs of photocells are located on two lightweight frames attached to the upper and lower frontal teeth by individually adapted clutches. By using the formulas of rigid body mathematics, the motion of any point of the mandible can be reconstructed. The system permits a high sampling frequency of at least 300 Hz per photocell co-ordinate. The noise, linearity and accuracy are better than 0·08 mm, 0·07 mm and 0·13 mm for points in the lower incisal region, and better than 0·25 mm, 0·17 mm and 0·27 mm for points in the condylar region. Thus jaw movements can be recorded with a high spatial and temporal resolution.

[1]  E. H. Furnée,et al.  TV / computer motion analysis systems: the first two decades , 1989 .

[2]  A Pedotti,et al.  A system for the study of jaw movements. , 1993, Cranio : the journal of craniomandibular practice.

[3]  B. Jankelson,et al.  Kinesiometric instrumentation: a new technology. , 1975, Journal of the American Dental Association.

[4]  J. H. de Vries A concept for a floating circle target tracker , 2006, Medical and Biological Engineering and Computing.

[5]  S Siegler,et al.  A technique to investigate the three-dimensional kinesiology of the human temporomandibular joint. , 1991, The Journal of prosthetic dentistry.

[6]  A. Lewin,et al.  The measurement of jaw movement. Part I. , 1976, The Journal of prosthetic dentistry (Print).

[7]  H. C. Lundeen,et al.  Condylar movement recordings for analyzing TMJ derangements. , 1988, Journal of craniomandibular disorders : facial & oral pain.

[8]  S. Palla,et al.  The relationship between condylar rotation and anterior translation in healthy and clicking temporomandibular joints. , 1988, Schweizer Monatsschrift fur Zahnmedizin = Revue mensuelle suisse d'odonto-stomatologie = Rivista mensile svizzera di odontologia e stomatologia.

[9]  F. Veldpaus,et al.  A least-squares algorithm for the equiform transformation from spatial marker co-ordinates. , 1988, Journal of biomechanics.

[10]  J. Lemmer,et al.  The measurement of jaw movement. Part II , 1976 .

[11]  S Karlsson,et al.  Recording of mandibular movements by intraorally placed light emitting diodes. , 1977, Acta odontologica Scandinavica.

[12]  S Hobo,et al.  A kinematic investigation of mandibular border movement by means of an electronic measuring system. Part I: Development of the measuring system. , 1983, The Journal of prosthetic dentistry.