Use of personal measurements for ozone exposure assessment: a pilot study.

During summer 1991, we collected indoor, outdoor, and personal ozone concentration data as well as time-activity data in State College, Pennsylvania. These concentrations were measured for 23 children and their homes using passive ozone samplers. Outdoor concentrations were also measured at a stationary ambient monitoring site. Results from this pilot study demonstrate that fixed-site ambient measurements may not adequately represent individual exposures. Outdoor ozone concentrations showed substantial spatial variation between rural and residential regions. Ignoring this spatial variation by using fixed-site measurements to estimate personal exposures can result in an error as high as 127%. In addition, evidence from our pilot study indicates that ozone concentrations of a single indoor microenvironment may not represent those of other indoor microenvironments. Personal exposures were significantly correlated with both indoor (r = 0.55) and outdoor (r = 0.41) concentrations measured at home sites. Multiple regression analyses identified indoor ozone concentrations as the most important predictors of personal exposures. However, models based on time-weighted indoor and outdoor concentrations explained only 40% of the variability in personal exposures. When the model included observations for only those participants who spent the majority of their day in or near their homes, an R2 of 0.76 resulted when estimates were regressed on measured personal exposures. It is evident that contributions from diverse indoor and outdoor microenvironments must be considered to estimate personal ozone exposures accurately. Imagesp318-aFigure 1.Figure 2.Figure 3.

[1]  P. Koutrakis,et al.  Measurement of ambient ozone using a nitrite-coated filter , 1993 .

[2]  P J Lioy,et al.  The effect of ozone associated with summertime photochemical smog on the frequency of asthma visits to hospital emergency departments. , 1992, Environmental research.

[3]  H Zwick,et al.  Effects of ozone on the respiratory health, allergic sensitization, and cellular immune system in children. , 1991, The American review of respiratory disease.

[4]  M Lippmann,et al.  Effects of single- and multiday ozone exposures on respiratory function in active normal children. , 1991, Environmental research.

[5]  D. Abbey,et al.  Long-term ambient concentrations of total suspended particulates and oxidants as related to incidence of chronic disease in California Seventh-Day Adventists. , 1991, Environmental health perspectives.

[6]  P J Lioy,et al.  Accumulated exposure to ozone and measurement of health effects in children and counselors at two summer camps. , 1991, Environmental research.

[7]  D V Bates,et al.  Asthma attack periodicity: a study of hospital emergency visits in Vancouver. , 1990, Environmental research.

[8]  C J Weschler,et al.  Indoor ozone exposures. , 1989, JAPCA.

[9]  S. R. Hayes,et al.  Estimating the effect of being indoors on total personal exposure to outdoor air pollution. , 1989, JAPCA.

[10]  J. Ware,et al.  A critical evaluation of acute ozone epidemiology results. , 1988, Archives of environmental health.

[11]  F. Speizer,et al.  Effects of ambient ozone on respiratory function in active, normal children. , 1988, The American review of respiratory disease.

[12]  F. Massey,et al.  The UCLA population studies of chronic obstructive respiratory disease. 9. Lung function changes associated with chronic exposure to photochemical oxidants; a cohort study among never-smokers. , 1987, Chest.

[13]  D V Bates,et al.  Air pollution and hospital admissions in Southern Ontario: the acid summer haze effect. , 1987, Environmental research.

[14]  W W Nazaroff,et al.  Mathematical modeling of chemically reactive pollutants in indoor air. , 1986, Environmental science & technology.

[15]  M. Lebowitz,et al.  Respiratory symptoms and peak flow associated with indoor and outdoor air pollutants in the southwest. , 1985, Journal of the Air Pollution Control Association.

[16]  M. Lebowitz,et al.  Indoor-outdoor air pollution, allergen and meteorological monitoring in an arid Southwest area. , 1984, Journal of the Air Pollution Control Association.

[17]  Trevor D. Davies,et al.  Indoor/outdoor ozone concentrations at a contemporary art gallery , 1984 .

[18]  C. Spicer The distribution of oxidized nitrogen in urban air. , 1982, The Science of the total environment.

[19]  D. Moschandreas,et al.  Comparison of indoor and outdoor air quality. Final report, March 1981 , 1981 .

[20]  R. Detels,et al.  The UCLA population studies of chronic obstructive respiratory disease. II. Determination of reliability and estimation of sensitivity and specificity. , 1979, Environmental research.

[21]  R A Wadden,et al.  Characterization of potential indoor sources of ozone. , 1978, American Industrial Hygiene Association journal.

[22]  Kenneth L. Heitner,et al.  Theoretical model for relating indoor pollutant concentrations to those outside , 1974 .

[23]  E. Hensel,et al.  Outdoor-indoor levels of six air pollutants. , 1973, Journal of the Air Pollution Control Association.

[24]  R. H. Sabersky,et al.  Concentrations, decay rates, and removal of ozone and their relation to establishing clean indoor air , 1973 .

[25]  Frank X. Mueller,et al.  Decomposition rates of ozone in living areas , 1973 .

[26]  F. B. Benson Indoor-Outdoor Air Pollution Relationship: A Literature Review. , 1972 .

[27]  D. Abbey,et al.  Long-term ambient concentrations of total suspended particulates, ozone, and sulfur dioxide and respiratory symptoms in a nonsmoking population. , 1993, Archives of environmental health.

[28]  B. Brunekreef,et al.  Effect of ambient ozone on peak expiratory flow of exercising children in The Netherlands. , 1993, Archives of environmental health.

[29]  Morton Lippmann,et al.  Effects of ozone on the pulmonary function of children , 1985 .

[30]  N. Duan,et al.  Models for human exposure to air pollution , 1982 .

[31]  R. Dietz,et al.  AIR INFILTRATION MEASUREMENTS IN A HOME USING A CONVENIENT PERFLUOROCARBON TRACER TECHNIQUE , 1982 .