Nonuniform disruption of lung architecture is usually assessed by CT, which carries potential radiation risk. Here we report our use of a three‐dimensional ultrashort echo time MR method to image the lungs of normal mice at different positive end‐expiratory pressures in a 3‐T clinical MR system. The ultrashort echo time sequence in conjunction with a projection acquisition of the free induction decay could reduce the echo time to 100 μsec and provide a more inherent MR signal intensity from the lung parenchyma, which is usually invisible due to its short T*2 in conventional MRI methods. The signal intensity and T*2 was reduced as the positive end‐expiratory pressure became higher. Further, these parameters were highly correlated to the changes in lung volume (% lung expansion). The results indicated that the MR signal acquired at ultrashort echo time in the lung parenchyma represents interstitial tissue density including blood. The capability of acquiring sufficient MR signal would have implications for the direct assessment of parenchymal architecture in the lung. Therefore, ultrashort echo time imaging may have the potential to assist detection of early and localized pathological destruction of lung tissue architecture observed in various pulmonary disorders such as emphysema without incurring the risks of radiation exposure. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.

[1]  Yoshiharu Ohno,et al.  Ultra‐short echo time (UTE) MR imaging of the lung: Comparison between normal and emphysematous lungs in mutant mice , 2010, Journal of magnetic resonance imaging : JMRI.

[2]  J. Hofland,et al.  Alveolar recruitment strategy and PEEP improve oxygenation, dynamic compliance of respiratory system and end‐expiratory lung volume in pediatric patients undergoing cardiac surgery for congenital heart disease , 2009, Paediatric anaesthesia.

[3]  T. Pilgram,et al.  Effects of diffusion time on short‐range hyperpolarized 3He diffusivity measurements in emphysema , 2009, Journal of magnetic resonance imaging : JMRI.

[4]  Dmitriy A Yablonskiy,et al.  Quantification of lung microstructure with hyperpolarized 3He diffusion MRI. , 2009, Journal of applied physiology.

[5]  W. Hop,et al.  Lung morphology assessment using MRI: A robust ultra‐short TR/TE 2D steady state free precession sequence used in cystic fibrosis patients , 2009, Magnetic resonance in medicine.

[6]  P. Gevenois,et al.  Pulmonary emphysema: size distribution of emphysematous spaces on multidetector CT images--comparison with macroscopic and microscopic morphometry. , 2008, Radiology.

[7]  H. Kauczor,et al.  Radiation dose reduction in chest CT: a review. , 2008, AJR. American journal of roentgenology.

[8]  O. Togao,et al.  Ultra-short echo time ( UTE ) MR imaging of the lung : Comparison between normal and emphysematous mice , 2008 .

[9]  J. Gee,et al.  MR microscopy of the lung in small rodents. , 2007, European journal of radiology.

[10]  Eiichi Fukushima,et al.  Short data‐acquisition times improve projection images of lung tissue , 2007, Magnetic resonance in medicine.

[11]  Peter Börnert,et al.  Selective 3D ultrashort TE imaging: comparison of “dual-echo” acquisition and magnetization preparation for improving short-T2 contrast , 2007, Magnetic Resonance Materials in Physics, Biology and Medicine.

[12]  P. Hockings,et al.  Measurement of MR signal and T2* in lung to characterize a tight skin mouse model of emphysema using single‐point imaging , 2007, Journal of magnetic resonance imaging : JMRI.

[13]  Dmitriy A Yablonskiy,et al.  Hyperpolarized 3He diffusion MRI and histology in pulmonary emphysema , 2006, Magnetic resonance in medicine.

[14]  D. Tenen,et al.  Three‐dimensional magnetic resonance microscopy of pulmonary solitary tumors in transgenic mice , 2006, Magnetic resonance in medicine.

[15]  Bernhard Geiger,et al.  Magnetic resonance lung function – a breakthrough for lung imaging and functional assessment? A phantom study and clinical trial , 2006, Respiratory research.

[16]  Guido Gerig,et al.  User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliability , 2006, NeuroImage.

[17]  Peter Börnert,et al.  Three‐dimensional radial ultrashort echo‐time imaging with T2 adapted sampling , 2006, Magnetic resonance in medicine.

[18]  A. Bankier,et al.  Gravity‐dependent signal gradients on MR images of the lung in supine and prone positions: A comparison with isogravitational signal variability , 2006, Journal of magnetic resonance imaging : JMRI.

[19]  Graeme M. Bydder,et al.  MR imaging with ultrashort TE (UTE) pulse sequences: Basic principles , 2005 .

[20]  Clarke G. Tankersley,et al.  Differences in alveolar size in inbred mouse strains , 2004, Respiratory Physiology & Neurobiology.

[21]  M. Kalra,et al.  Application of Rational Practice and Technical Advances for Optimizing Radiation Dose for Chest CT , 2004, Journal of thoracic imaging.

[22]  E. Hoffman,et al.  Characterization of the interstitial lung diseases via density-based and texture-based analysis of computed tomography images of lung structure and function. , 2003, Academic radiology.

[23]  James D Crapo,et al.  Clinical research in chronic obstructive pulmonary disease: needs and opportunities. , 2003, American journal of respiratory and critical care medicine.

[24]  J. Fozard,et al.  MRI of lung parenchyma in rats and mice using a gradient‐echo sequence , 2001, NMR in biomedicine.

[25]  E. Kazerooni Radiologic evaluation of emphysema for lung volume reduction surgery. , 1999, Clinics in chest medicine.

[26]  D. Hansell High-resolution computed tomography in the evaluation of fibrosing alveolitis. , 1999, Clinics in chest medicine.

[27]  H. Hatabu,et al.  Fast magnetic resonance imaging of the lung. , 1999, European journal of radiology.

[28]  P. Croisille,et al.  Lung perfusion demonstrated by contrast-enhanced dynamic magnetic resonance imaging. Application to unilateral lung transplantation. , 1997, Investigative radiology.

[29]  O. Haraldseth,et al.  Pulmonary embolism: detection with MR perfusion imaging of lung--a feasibility study. , 1997, Radiology.

[30]  R. Edelman,et al.  Pulmonary perfusion and angiography: evaluation with breath-hold enhanced three-dimensional fast imaging steady-state precession MR imaging with short TR and TE. , 1996, AJR. American journal of roentgenology.

[31]  C. Durney,et al.  Comparison of calculated and experimental NMR spectral broadening for lung tissue , 1996, Magnetic resonance in medicine.

[32]  C. Durney,et al.  Lung water measurement by nuclear magnetic resonance: correlation with morphometry. , 1995, Journal of applied physiology.

[33]  J Listerud,et al.  Multi‐Slice, Breathhold Imaging of the Lung with Submillisecond Echo Times , 1995, Magnetic resonance in medicine.

[34]  Sam T. S. Wong,et al.  A strategy for sampling on a sphere applied to 3D selective RF pulse design , 1994, Magnetic resonance in medicine.

[35]  J R MacFall,et al.  MR microscopy of the rat lung using projection reconstruction , 1993, Magnetic resonance in medicine.

[36]  Aaron J. Miller,et al.  The use of power images to perform quantitative analysis on low SNR MR images. , 1993, Magnetic resonance imaging.

[37]  J. Pauly,et al.  Boron‐11 imaging with a three‐dimensional reconstruction method , 1992, Journal of magnetic resonance imaging : JMRI.

[38]  J M Pauly,et al.  Lung parenchyma: projection reconstruction MR imaging. , 1991, Radiology.

[39]  J. Clausen The diagnosis of emphysema, chronic bronchitis, and asthma. , 1990, Clinics in chest medicine.

[40]  N. Müller,et al.  "Density mask". An objective method to quantitate emphysema using computed tomography. , 1988, Chest.

[41]  D. Šuput,et al.  Water proton NMR relaxation mechanisms in lung tissue , 1988, Magnetic resonance in medicine.

[42]  Alan H. Morris,et al.  A mathematical model of diamagnetic line broadening in lung tissue and similar heterogeneous systems: Calculations and measurements , 1987 .

[43]  H Lum,et al.  A species comparison of alveolar size and surface forces. , 1987, Journal of applied physiology.

[44]  C. Durney,et al.  Lung water quantitation by nuclear magnetic resonance imaging. , 1982, Science.

[45]  J. C. Norman,et al.  Alveolar morphometrics: effects of positive end-expiratory pressure. , 1974, Surgery.