Energy and Quality Evaluation for Compressive Sensing of Fetal Electrocardiogram Signals

This manuscript addresses the problem of non-invasive fetal Electrocardiogram (ECG) signal acquisition with low power/low complexity sensors. A sensor architecture using the Compressive Sensing (CS) paradigm is compared to a standard compression scheme using wavelets in terms of energy consumption vs. reconstruction quality, and, more importantly, vs. performance of fetal heart beat detection in the reconstructed signals. We show in this paper that a CS scheme based on reconstruction with an over-complete dictionary has similar reconstruction quality to one based on wavelet compression. We also consider, as a more important figure of merit, the accuracy of fetal beat detection after reconstruction as a function of the sensor power consumption. Experimental results with an actual implementation in a commercial device show that CS allows significant reduction of energy consumption in the sensor node, and that the detection performance is comparable to that obtained from original signals for compression ratios up to about 75%.

[1]  Sebastian Zaunseder,et al.  An ECG simulator for generating maternal-foetal activity mixtures on abdominal ECG recordings , 2014, Physiological measurement.

[2]  Pierre Vandergheynst,et al.  Compressed Sensing for Real-Time Energy-Efficient ECG Compression on Wireless Body Sensor Nodes , 2011, IEEE Transactions on Biomedical Engineering.

[3]  Roberto Rinaldo,et al.  Separation and Analysis of Fetal-ECG Signals From Compressed Sensed Abdominal ECG Recordings , 2016, IEEE Transactions on Biomedical Engineering.

[4]  Arnon D. Cohen,et al.  The weighted diagnostic distortion (WDD) measure for ECG signal compression , 2000, IEEE Transactions on Biomedical Engineering.

[5]  Jayawan H. B. Wijekoon,et al.  Continuous objective recording of fetal heart rate and fetal movements could reliably identify fetal compromise, which could reduce stillbirth rates by facilitating timely management. , 2014, Medical hypotheses.

[6]  C. Goodman Association for the Advancement of Medical Instrumentation , 1988 .

[7]  D. Arar,et al.  Fixed percentage of wavelet coefficients to be zeroed for ECG compression , 2003 .

[8]  Willis J. Tompkins,et al.  A Real-Time QRS Detection Algorithm , 1985, IEEE Transactions on Biomedical Engineering.

[9]  Tzyy-Ping Jung,et al.  Compressed Sensing for Energy-Efficient Wireless Telemonitoring of Noninvasive Fetal ECG Via Block Sparse Bayesian Learning , 2012, IEEE Transactions on Biomedical Engineering.

[10]  Riccardo Bernardini,et al.  Gaussian dictionary for Compressive Sensing of the ECG signal , 2014, 2014 IEEE Workshop on Biometric Measurements and Systems for Security and Medical Applications (BIOMS) Proceedings.

[11]  Joos Vandewalle,et al.  Fetal electrocardiogram extraction by blind source subspace separation , 2000, IEEE Transactions on Biomedical Engineering.

[12]  E.J. Candes Compressive Sampling , 2022 .

[13]  Giuseppe Andreoni,et al.  Prototype of a wearable system for remote fetal monitoring during pregnancy , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[14]  Christian Jutten,et al.  A Fast Approach for Overcomplete Sparse Decomposition Based on Smoothed $\ell ^{0}$ Norm , 2008, IEEE Transactions on Signal Processing.

[15]  Ingrid Daubechies,et al.  The wavelet transform, time-frequency localization and signal analysis , 1990, IEEE Trans. Inf. Theory.

[16]  R. DeVore,et al.  A Simple Proof of the Restricted Isometry Property for Random Matrices , 2008 .

[17]  Adrian Burns,et al.  SHIMMER™ – A Wireless Sensor Platform for Noninvasive Biomedical Research , 2010, IEEE Sensors Journal.

[18]  Gari D Clifford,et al.  Combining and benchmarking methods of foetal ECG extraction without maternal or scalp electrode data , 2014, Physiological measurement.

[19]  Yonina C. Eldar,et al.  Compressed Sensing with Coherent and Redundant Dictionaries , 2010, ArXiv.

[20]  Erkki Oja,et al.  Independent component analysis: algorithms and applications , 2000, Neural Networks.

[21]  S. Frick,et al.  Compressed Sensing , 2014, Computer Vision, A Reference Guide.

[22]  Roberto Rinaldo,et al.  Robust reconstruction for CS-based fetal beats detection , 2016, 2016 24th European Signal Processing Conference (EUSIPCO).

[23]  Gari D Clifford,et al.  Non-invasive fetal ECG analysis , 2014, Physiological measurement.