Assessment of capacity design of columns in steel moment resisting frames with viscous dampers

Previous research showed that steel moment-resisting frames (MRFs) with viscous dampers may experience column plastic hinges under strong earthquakes and highlighted the need to further assess the efficiency of capacity design rules. To partially address this need, three alternatives of a prototype building having five, 10 and 20 stories are designed according to Eurocode 8 using either steel MRFs or steel MRFs with dampers. Incremental dynamic analysis (IDA) is conducted for all MRFs and their collapse resistance and plastic mechanism is evaluated. The results show that steel MRFs with dampers are prone to column plastic hinging in comparison to steel MRFs. The steel MRFs with dampers are then iteratively re-designed with stricter capacity design rules to achieve a plastic mechanism that is approximately similar to that of steel MRFs. The performance of these re-designed steel MRFs with dampers indicates, that overall, enforcement of stricter capacity design rules for columns is not justified neither from a collapse resistance or a reparability perspective.

[1]  Constantin Christopoulos,et al.  Performance spectra based method for the seismic design of structures equipped with passive supplemental damping systems , 2013 .

[2]  Dimitrios Vamvatsikos,et al.  Incremental dynamic analysis , 2002 .

[3]  Richard Sause,et al.  Seismic Response and Performance of a Steel MRF Building with Nonlinear Viscous Dampers under DBE and MCE , 2016 .

[4]  Andrea Dall'Asta,et al.  Probabilistic performance assessment of low‐ductility reinforced concrete frames retrofitted with dissipative braces , 2012 .

[5]  George D. Hatzigeorgiou,et al.  Inelastic velocity ratio , 2012 .

[6]  Andrea Dall'Asta,et al.  Probabilistic seismic response assessment of linear systems equipped with nonlinear viscous dampers , 2015 .

[7]  Anil K. Chopra,et al.  Earthquake Response of Elastic Single-Degree-of-Freedom Systems with Nonlinear Viscoelastic Dampers , 2003 .

[8]  Michael C. Constantinou,et al.  Response of Nonstructural Components in Structures with Damping Systems , 2006 .

[9]  Michel Bruneau,et al.  Steel Structures Damage from the Christchurch Earthquake Series of 2010 and 2011 , 2011 .

[10]  Andrew S. Whittaker,et al.  Evaluation of Simplified Methods of Analysis of Yielding Structures with Damping Systems , 2002 .

[11]  Martin S. Williams,et al.  A Comparison of Viscous Damper Placement Methods for Improving Seismic Building Design , 2012 .

[12]  Helmut Krawinkler,et al.  Deterioration Modeling of Steel Components in Support of Collapse Prediction of Steel Moment Frames under Earthquake Loading , 2011 .

[13]  Akira Wada,et al.  Limit states and failure mechanisms of viscous dampers and the implications for large earthquakes , 2010 .

[14]  Michael C. Constantinou,et al.  Investigation of Seismic Response of Buildings with Linear and Nonlinear Fluid Viscous Dampers , 1997 .

[15]  Kazuhiko Kasai,et al.  Full-scale tests of passively-controlled 5-story steel building using E-Defense shake table Part 1: Test concept, method, and building specimen , 2009 .

[16]  Andrew S. Whittaker,et al.  Energy dissipation systems for seismic applications: Current practice and recent developments , 2008 .

[17]  Fabio Freddi,et al.  Probabilistic seismic demand modeling of local level response parameters of an RC frame , 2016, Bulletin of Earthquake Engineering.

[18]  James M. Ricles,et al.  Seismic performance and probabilistic collapse resistance assessment of steel moment resisting frames with fluid viscous dampers , 2014 .

[19]  Marco Baiguera,et al.  Dual seismic-resistant steel frame with high post-yield stiffness energy-dissipative braces for residual drift reduction , 2016 .

[20]  Laura Ragni,et al.  Influence of the nonlinear behavior of viscous dampers on the seismic demand hazard of building frames , 2016 .

[21]  N. Null Minimum Design Loads for Buildings and Other Structures , 2003 .

[22]  Andrew S. Whittaker,et al.  Equivalent Lateral Force and Modal Analysis Procedures of the 2000 NEHRP Provisions for Buildings with Damping Systems , 2003 .

[23]  M. Constantinou,et al.  Elastic and Inelastic Seismic Response of Buildings with Damping Systems , 2002 .

[24]  Andre Filiatrault,et al.  Influence of passive supplemental damping systems on structural and nonstructural seismic fragilities of a steel building , 2008 .

[25]  H Krawinkler,et al.  Shear in Beam-Column Joints in Seismic Design of Steel Frames , 1978, Engineering Journal.

[26]  Theodore L. Karavasilis,et al.  Seismic structural and non-structural performance evaluation of highly damped self-centering and conventional systems , 2011 .