Commercial multileaf collimator (MLC) systems can employ leaves with rounded ends. Treatment planning beam modelling should consider the effects of transmission through rounded leaf ends to provide accurate dosimetry for IMRT treatments delivered with segmented MLC. We determined that an MLC leaf gap reduction of 1.4 mm is required to obtain an agreement between calculated and measured profile 50% dose points. A head and neck dosimetry phantom, supplied by the Radiological Physics Center (RPC), was planned and irradiated as a necessary credentialing requirement for the RTOG H-0022 protocol. The agreement between the RPC TLD measurements and treatment planning calculations was within experimental error for the primary and secondary planning target volumes (PTVs); however, the calculated mean dose for the critical structure was approximately 9% lower than the RPC TLD measurements. RPC radiochromic film profile measurements also indicated significant discrepancies (>5%) with calculated values especially in the high dose gradient region in the vicinity of the critical structure. These results substantiate our own in-house phantom measurements, performed with the same IMRT fields as for the RPC phantom experiment, using Kodak EDR2 film to measure absolute dose. Our results indicate a maximum underestimate of calculated dose of 12% with no leaf gap reduction. The discrepancy between measured and calculated phantom values is reduced to +/- 5% when a leaf gap reduction of 1.4 mm is used. A further improvement in the accuracy of dose calculation is not possible without a more accurate modelling of the leaf end transmission by the planning system. In the absence of published dosimetric criteria for IMRT our results stress the need for stringent in-house dosimetric QA and validation for IMRT treatments. We found the dosimetric validation service provided by the RPC to be a valuable component of our IMRT validation efforts.
[1]
T LoSasso,et al.
Dosimetric verification of intensity-modulated fields.
,
1996,
Medical physics.
[2]
G. Starkschall,et al.
American Association of Physicists in Medicine Radiation Therapy Committee Task Group 53: quality assurance for clinical radiotherapy treatment planning.
,
1998,
Medical physics.
[3]
G T Chen,et al.
Intensity modulated radiotherapy dose delivery error from radiation field offset inaccuracy.
,
2000,
Medical physics.
[4]
T LoSasso,et al.
Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode.
,
2001,
Medical physics.