Stereotactic radiotherapy of malignancies in the abdomen. Methodological aspects.

A method for stereotactic high-dose radiotherapy of malignancies in the abdomen has been developed. A stereotactic frame for the body has been developed and a method for fixation of the patient in the frame is described. The reproducibility in the stereotactic system of tumours in the liver and the lung was found to be within 5-8 mm for 90% of the patient set-ups. The diaphragmatic movements were reduced to 5-10 mm, by applying a pressure on the abdomen. An analytical method is used to calculate dose distributions for a continuum of beams in an isocentric treatment technique. The advantage of a heterogeneous target dose is demonstrated and proposed for the present application. A non-coplanar treatment technique, using eight individually shaped beams is proposed and has been used for patient treatments. The dose distribution for a patient with a metastasis in the liver is shown as well as dose volume histograms for the target and the liver.

[1]  L. Peters,et al.  Concomitant boost radiotherapy for advanced squamous cell carcinoma of the head and neck. , 1985, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[2]  D L McShan,et al.  Technical considerations in the use of 3-D beam arrangements in the abdomen. , 1991, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[3]  A. Nahum,et al.  A comparison of techniques for stereotactic radiotherapy by linear accelerator based on 3-dimensional dose distributions. , 1991, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[4]  J. Lebesque,et al.  The simultaneous boost technique: the concept of relative normalized total dose. , 1991, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[5]  Marc L. Kessler,et al.  The use of 3-D dose volume analysis to predict radiation hepatitis. , 1991 .

[6]  M. Goitein,et al.  Tolerance of normal tissue to therapeutic irradiation. , 1991, International journal of radiation oncology, biology, physics.

[7]  Jack F. Fowler,et al.  Brief summary of radiobiological principles in fractionated radiotherapy , 1992 .

[8]  H. Hoekstra,et al.  Tissue tolerance of normal and surgically manipulated canine liver to intraoperative radiation therapy (IORT). , 1993, International journal of radiation oncology, biology, physics.

[9]  I. Lax Target dose versus extratarget dose in stereotactic radiosurgery. , 1993, Acta oncologica.

[10]  R. Laing,et al.  Stereotactic radiotherapy of irregular targets: a comparison between static conformal beams and non-coplanar arcs. , 1993, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.