Accuracy of intraocular pressure measurements in dogs using two different tonometers and plano therapeutic soft contact lenses.
暂无分享,去创建一个
K. Seo | Euiri Lee | M. Jeong | Seeun Kim | Youngwoo Park | Jeongtaek Ahn | Yesran Lee | J. Ahn | Eui-Ri Lee
[1] K. Seo,et al. Effect of central corneal thickness on intraocular pressure with the rebound tonometer and the applanation tonometer in normal dogs. , 2011, Veterinary ophthalmology.
[2] A. Loewenstein,et al. Intraocular pressure measurements in relation to head position and through soft contact lenses: comparison of three portable instruments. , 2011, Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye.
[3] M. Hässig,et al. Evaluation of a rebound tonometer (Tonovet) in clinically normal cat eyes. , 2010, Veterinary ophthalmology.
[4] E. Chihara. Assessment of true intraocular pressure: the gap between theory and practical data. , 2008, Survey of ophthalmology.
[5] G. Saleh,et al. Applanation tonometry in silicone hydrogel contact lens wearers. , 2004, Contact lens & anterior eye : the journal of the British Contact Lens Association.
[6] H. Uusitalo,et al. Comparison of simultaneous readings of intraocular pressure in rabbits using Perkins handheld, Tono-Pen XL, and TonoVet tonometers , 2007, Graefe's Archive for Clinical and Experimental Ophthalmology.
[7] M. Boevé,et al. Comparison of the use of new handheld tonometers and established applanation tonometers in dogs. , 2006, American journal of veterinary research.
[8] P. Khaw,et al. Accuracy of intraocular pressure measurements in new zealand white rabbits. , 2005, Investigative ophthalmology & visual science.
[9] P. Barrett,et al. Abstract Title: An Evaluation of the TonoVet® Rebound Tonometer for Measuring Intraocular Pressure in Dogs and Horses , 2005 .
[10] D. Luce. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer , 2005, Journal of cataract and refractive surgery.
[11] W. Illahi,et al. Non-contact tonometry over soft contact lenses: effect of contact lens power on the measurement of intra-ocular pressure. , 2004, Contact lens & anterior eye : the journal of the British Contact Lens Association.
[12] D. Tan,et al. Accurate intraocular pressure measurement in contact lens wearers with normal pressures. , 1997, The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc.
[13] P. Donshik,et al. The effects of therapeutic contact lenses on intraocular pressure measurement. , 1996, The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc.
[14] P. Kaufman,et al. Intraocular pressure measurement in cynomolgus monkeys. Tono-Pen versus manometry. , 1996, Investigative ophthalmology & visual science.
[15] C. Murphy,et al. Intraocular pressure measurement through two types of plano therapeutic soft contact lenses in dogs. , 1995, American journal of veterinary research.
[16] J. Morrison,et al. Noninvasive measurement of rat intraocular pressure with the Tono-Pen. , 1993, Investigative ophthalmology & visual science.
[17] P. Asbell,et al. Accuracy of Intraocular Pressure Measurements with Two Different Tonometers Through Bandage Contact Lenses , 1992, Cornea.
[18] L. Janoff. Intraocular pressure measurements with the tonopen II over a disposable soft lens , 1991 .
[19] I. Kurzman,et al. Evaluation of two applanation tonometers in cats. , 1991, American journal of veterinary research.
[20] J. Pickett,et al. Evaluation of two applanation tonometers in horses. , 1990, American journal of veterinary research.
[21] W. A. Boothe,et al. Intraocular pressure measurement with the Tono-Pen through soft contact lenses. , 1990, American journal of ophthalmology.
[22] J. A. Khan,et al. Tono-Pen estimation of intraocular pressure through bandage contact lenses. , 1989, American journal of ophthalmology.
[23] C. McMonnies. Noncontact Tonometry through Soft Contact Lenses , 1986, American journal of optometry and physiological optics.
[24] T. Deutsch,et al. Pneumatonometry through bandage contact lenses. , 1985, Archives of ophthalmology.
[25] Club Jules Gonin,et al. Graefe's archive for clinical and experimental ophthalmology , 1982 .
[26] R. Meyer,et al. Mackay-Marg tonometry over therapeutic soft contact lenses. , 1978, American journal of ophthalmology.
[27] Schmidt Tf. On applanation tonometry. , 1961 .