Potential Applications of Computational Fluid Dynamics for Predicting Hemolysis in Mitral Paravalvular Leaks

Paravalvular leaks (PVLs) may lead to hemolysis. In vitro shear stress forces above 300 Pa cause erythrocyte destruction. PVL channel dimensions may determine magnitude of shear stress forces that affect erythrocytes; however, this has not been tested. It remains unclear how different properties of PVL channels contribute to presence of hemolysis. A model of a left ventricle was created based on data from computer tomography with Slicer software PVLs of various shapes and sizes were introduced. Blood flow was simulated using ANSYS Fluent software. The following variables were examined: wall shear stress, shear stress in fluid, volume of PVL channel with shear stress exceeding 300 Pa, and duration of exposure of erythrocytes to shear stress values above 300 Pa. In all models, shear stress forces exceeded 300 Pa. Shear stress increased with blood flow rates and cross-sectional areas of any PVL. There was no linear relationship between cross-sectional area of a PVL and volume of a PVL channel with shear stress > 300 Pa. Blood flow through mitral PVLs is associated with shear stress above 300 Pa. Cross-sectional area of a PVL does not correlate with volume of a PVL channel with shear stress > 300 Pa and duration of exposure of erythrocytes to shear stress > 300 Pa.

[1]  V. Agnese,et al.  Simulation of left ventricular outflow tract (LVOT) obstruction in transcatheter mitral valve-in-ring replacement. , 2020, Medical engineering & physics.

[2]  V. Agnese,et al.  Simulation study of transcatheter heart valve implantation in patients with stenotic bicuspid aortic valve , 2020, Medical & Biological Engineering & Computing.

[3]  Dalin Tang,et al.  Expert recommendations on the assessment of wall shear stress in human coronary arteries: existing methodologies, technical considerations, and clinical applications , 2019, European heart journal.

[4]  A. Delabays,et al.  Percutaneous closure of mitral paravalvular leaks: Focus on imaging and technique , 2017 .

[5]  Giovanni Gentile,et al.  Three‐dimensional parametric modeling of bicuspid aortopathy and comparison with computational flow predictions , 2017, Artificial organs.

[6]  Achille Iolascon,et al.  New insights on hereditary erythrocyte membrane defects , 2016, Haematologica.

[7]  I. Cruz-González,et al.  Percutaneous Closure of Paravalvular Leaks: A Systematic Review. , 2016, Journal of interventional cardiology.

[8]  T. Roleder,et al.  Transcatheter closure of paravalvular leaks using a paravalvular leak device – a prospective Polish registry , 2016, Postepy w kardiologii interwencyjnej = Advances in interventional cardiology.

[9]  Caroline C. O'Brien,et al.  The Impact of Blood Rheology on Drug Transport in Stented Arteries: Steady Simulations , 2015, PloS one.

[10]  I. Kronzon,et al.  Review of surgical prosthetic paravalvular leaks: diagnosis and catheter-based closure. , 2013, European heart journal.

[11]  Milan Sonka,et al.  3D Slicer as an image computing platform for the Quantitative Imaging Network. , 2012, Magnetic resonance imaging.

[12]  D. Birchall,et al.  Analysis of haemodynamic disturbance in the atherosclerotic carotid artery using computational fluid dynamics , 2006, European Radiology.

[13]  A. Fraser,et al.  Prevalence and clinical significance of incidental paraprosthetic valvar regurgitation: a prospective study using transoesophageal echocardiography , 2003, Heart.

[14]  J D Thomas,et al.  Mechanisms of hemolysis with mitral prosthetic regurgitation. Study using transesophageal echocardiography and fluid dynamic simulation. , 1996, Journal of the American College of Cardiology.

[15]  J. D. Hellums,et al.  Erythrocyte damage and destruction induced by shearing stress. , 1968, The Journal of laboratory and clinical medicine.