Transient Performance of Series-Compensated Three-Phase Self-Excited Induction Generator Feeding Dynamic Loads

This paper presents the transient performance of a series-compensated three-phase self-excited induction generator (SEIG) feeding a dynamic load such as a three-phase squirrel-cage induction motor (IM). Mathematical modeling and simulation study of SEIG and an induction motor (SEIG-IM) combination is carried out using MATLAB/Simulink. An exhaustive experimental study is conducted using a Mawdsley's generalized machine operating as a SEIG and a three-phase squirrel-cage IM as the dynamic load. The simulated results are compared with the experimental results under various operating conditions of the SEIG such as the following: 1) its voltage and current buildup at no-load; 2) switching of a three-phase squirrel-cage IM to the SEIG terminals without series-compensating capacitors (resulting failure to start an IM); and 3) switching on the same motor with the series capacitors (resulting in successful starting of the IM). A sudden switching of the IM as a dynamic load on the SEIG without the series compensation causes severe transients in electrical and mechanical variables of the SEIG and due to large starting current requirement of the IM, there is a collapse of the terminal voltage of SEIG. However, the use of series compensation in short-shunt configuration of SEIG results in the successful starting of the IM with an improved voltage regulation of SEIG. The phenomenon of subsynchronous resonance (SSR) is observed due to the large variations in the impedance of the SEIG-IM combination and the presence of series capacitors. It causes low frequency oscillations in the IM stator voltages, currents, and its speed. The SSR phenomenon restricts the IM to attain the rated speed. A detailed study of the SEIG-IM system is made to select proper combination of shunt and series capacitors to avoid the SSR phenomenon.

[1]  Sebastiao E. M. de Oliveira Starting Transients of Saturated Induction Motors with Series Capacitors on the Supply , 1986, IEEE Power Engineering Review.

[2]  T.F. Chan,et al.  Steady-state analysis of self-excited induction generators , 1994, IEEE Power Engineering Review.

[3]  F. M. Porter,et al.  Capacitive excitation for induction generators , 1935, Electrical Engineering.

[4]  I. Report First Supplement to a Bibliography for the Study of Subsynchronous Resonance Between Rotating Machines and Power Systems , 1979, IEEE Transactions on Power Apparatus and Systems.

[5]  R. Bonert,et al.  Self-excited induction generator with excellent voltage and frequency control , 1998 .

[6]  Li Wang,et al.  Long-shunt and short-shunt connections on dynamic performance of a SEIG feeding an induction motor load , 2000 .

[7]  P. Vas,et al.  The analysis of a saturated self-excited asynchronous generator , 1991 .

[8]  O. P. Malik,et al.  Analysis of self-excited induction generators , 1982 .

[9]  Bhim Singh,et al.  Transient performance of the self regulated short shunt self excited induction generator , 1995 .

[10]  M. B. Brennen,et al.  Static Exciters for Induction Generators , 1977, IEEE Transactions on Industry Applications.

[11]  Li Wang,et al.  Dynamic analyses of parallel operated self-excited induction generators feeding an induction motor load , 1999 .

[12]  Cheng-Tsung Liu,et al.  Transient simulation technique for studies of self-excited generator systems , 1995 .

[13]  Li Wang,et al.  Transient performance of an isolated induction generator under unbalanced excitation capacitors , 1999 .

[14]  Paul C. Krause,et al.  Analysis of electric machinery , 1987 .

[15]  B. G. Fernandes,et al.  Voltage and frequency control of parallel operated synchronous generator and induction generator with STATCOM in micro hydro scheme , 2007 .

[16]  B. P. Singh,et al.  Analysis of self excited induction generator feeding induction motor , 1994 .

[17]  J.K. Chatterjee,et al.  Voltage and Frequency Control of a Stand Alone Brushless Wind Electric Generation Using Generalized Impedance Controller , 2008, IEEE Transactions on Energy Conversion.

[18]  B. Singh,et al.  Analysis and design of STATCOM-based voltage regulator for self-excited induction generators , 2004, IEEE Transactions on Energy Conversion.

[19]  C. F. Wagner,et al.  Self-excitation of induction motors , 1939, Electrical Engineering.

[20]  Sebastiao E.M. de Oliveira Starting Transients of Saturated Induction Motors with Series Capacitors on the Supply , 1986, IEEE Transactions on Energy Conversion.

[21]  Enes Gonçalves Marra,et al.  Induction-generator-based system providing regulated voltage with constant frequency , 2000, IEEE Trans. Ind. Electron..

[22]  Li Wang,et al.  Analysis of voltage control for a self-excited induction generator using a current-controlled voltage source inverter (CC-VSI) , 2001 .

[23]  L.L. Lai,et al.  Voltage and frequency control of self-excited slip-ring induction generators , 2004, IEEE Transactions on Energy Conversion.

[24]  Bhim Singh,et al.  Selection of capacitors for the self regulated short shunt self excited induction generator , 1995 .

[25]  Bhim Singh,et al.  STATCOM-Based Voltage Regulator for Self-Excited Induction Generator Feeding Nonlinear Loads , 2006, IEEE Transactions on Industrial Electronics.

[26]  T. F. Chan,et al.  Capacitance requirements of self-excited induction generators , 1993 .

[27]  G. Bortolotto,et al.  Voltage-frequency control of a self-excited induction generator , 1999 .

[28]  Bhim Singh,et al.  Analysis of a novel solid state voltage regulator for a self-excited induction generator , 1998 .

[29]  Bhim Singh,et al.  Analysis and implementation of an electronic load controller for a self-excited induction generator , 2004 .

[30]  S. S. Venkata,et al.  An Adaptive Power Factor Controller for Three-Phase Induction Generators , 1985, IEEE Power Engineering Review.

[31]  R. Bonert,et al.  Stand alone induction generator with terminal impedance controller and no turbine controls , 1990 .

[32]  Sanjay Kumar Jain,et al.  Transient performance of three-phase self-excited induction generator during balanced and unbalanced faults , 2002 .

[33]  Jose Antenor Pomilio,et al.  Self-excited induction generator controlled by a VS-PWM bidirectional converter for rural applications , 1999 .

[34]  Bhim Singh,et al.  Improvements in the performance of self-excited induction generator through series compensation , 1999 .

[35]  Bhim Singh,et al.  Dynamic behavior of a three-phase self-excited induction generator for single-phase power generation , 1998 .

[36]  B. Singh,et al.  Decoupled Voltage and Frequency Controller for Isolated Asynchronous Generators Feeding Three-Phase Four-Wire Loads , 2008, IEEE Transactions on Power Delivery.

[37]  D. Henderson AN ADVANCED ELECTRONIC LOAD GOVERNOR FOR CONTROL OF MICRO HYDROELECTRIC GENERATION , 1996 .

[38]  Li Wang,et al.  Steady-State Performance of a Self-Excited Induction Generator Feeding an Induction Motor , 2002 .

[39]  Li Wang,et al.  Analysis of Parallel-Operated Self-Excited Induction Generators Feeding an Induction Motor Load with a Long-Shunt Connection , 2004 .

[40]  Bhim Singh,et al.  STATCOM based voltage regulator for self-excited induction generator feeding non-linear loads , 2003, IECON'03. 29th Annual Conference of the IEEE Industrial Electronics Society (IEEE Cat. No.03CH37468).

[41]  Woei-Luen Chen,et al.  STATCOM Controls for a Self-Excited Induction Generator Feeding Random Loads , 2008, IEEE Transactions on Power Delivery.