Bending Forceps Manipulator with Offset Distance for Single-port Laparoscopy

By integrating locally operated, small surgical robots and devices, a surgeon can perform, robotically assisted laparoscopic surgery safely and accurately. However, no locally operated robotic forceps functioning as the third arm can provide the wide eld of view and the large working area required for single-incision laparoscopic surgery (SILS). For SILS using a locally operated third arm, the pivot point should be placed far from the other three instruments inserted through the single port, and the pivot axes should be bending. Size reduction of the differential geared mechanism is dif cult. Designing bending pivot axes for the exible worm mechanism is also dif cult. Bending pivot axes are also dif cult to achieve in the crank-curved manipulator that we proposed previously as the second arm. The crank distance is short because of the high-step cylinders. The curved forceps have low accuracy because of rubber deformation. In the present study, we modi ed the crank-curved manipulator and designed a new manipulator for use as the third arm in a sterile environment, which provides offset distance using lowstep cylinders in the pivot point placed far from the other instruments, as well as bending forceps mechanisms using ball joints in the bending pivot axes. We succeeded to develop a bending forceps manipulator with offset distance as a locally operated, end-effector manipulator (offset LODEM) for use as the third arm. The operating range was 60 mm for the offset, 32° for the pitch and yaw axes, and 24 mm for the insertion/extraction axis. Positional accuracy was evaluated while performing a simulated surgical procedure. The accuracy was 0.5 mm, which is suf cient for handling organs. The manipulator successfully handled the target in the simulated surgical procedures to provide a wide eld of view and a large working area. The offset LODEM was designed to allow minimally invasive, robotically assisted surgery performed by a doctor working near the patient. This device may be used for such applications.

[1]  Brice Gayet,et al.  Modified Robotic Lightweight Endoscope (ViKY) Validation In Vivo in a Porcine Model , 2007, Surgical innovation.

[2]  Peter K. Allen,et al.  Design, simulation and evaluation of kinematic alternatives for Insertable Robotic Effectors Platforms in Single Port Access Surgery , 2010, 2010 IEEE International Conference on Robotics and Automation.

[3]  G. Buess,et al.  Laparoscopic intracorporal colorectal sutured anastomosis using the Radius Surgical System in a phantom model , 2009, Surgical Endoscopy.

[4]  J. Romanelli,et al.  Single-port laparoscopic surgery: an overview , 2009, Surgical Endoscopy.

[5]  Paolo Dario,et al.  Design of a Novel Bimanual Robotic System for Single-Port Laparoscopy , 2010, IEEE/ASME Transactions on Mechatronics.

[6]  Russell H. Taylor,et al.  Medical robotics in computer-integrated surgery , 2003, IEEE Trans. Robotics Autom..

[7]  Ninh T. Nguyen,et al.  Laparoscopic Transumbilical Cholecystectomy Without Visible Abdominal Scars , 2009, Journal of Gastrointestinal Surgery.

[8]  Dmitry Oleynikov,et al.  Consensus statement of the consortium for LESS cholecystectomy , 2012, Surgical Endoscopy.

[9]  Toshikazu Kawai,et al.  Locally Operated Detachable End-effector Manipulator for Endoscopic Surgery , 2012 .

[10]  Tatsuo Nakamura,et al.  Hands-free interface for surgical procedures based on foot movement patterns , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  Y F Wang,et al.  A new framework for vision-enabled and robotically assisted minimally invasive surgery. , 1998, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[12]  Jun Okamoto,et al.  The concept and feasibility of EXPERT: intelligent armrest using robotics technology. , 2013, Neurosurgery.

[13]  K Masamune,et al.  A new safe laparoscopic manipulator system with a five-bar linkage mechanism and an optical zoom. , 1999, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[14]  Fumio Miyazaki,et al.  A novel locally operated master-slave robot system for single-incision laparoscopic surgery , 2014, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[15]  H. Scharf,et al.  Today's state of the art in surgical robotics , 2005, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[16]  J. Dankelman,et al.  The optimal mechanical efficiency of laparoscopic forceps , 2004, Surgical Endoscopy.

[17]  John Kenneth Salisbury,et al.  The Intuitive/sup TM/ telesurgery system: overview and application , 2000, Proceedings 2000 ICRA. Millennium Conference. IEEE International Conference on Robotics and Automation. Symposia Proceedings (Cat. No.00CH37065).

[18]  Tatsuo Nakamura,et al.  Mobile locally operated detachable end-effector manipulator for endoscopic surgery , 2014, International Journal of Computer Assisted Radiology and Surgery.