How to search the experimental conditions that improve a Partial Least Squares calibration model. Application to a flow system with electrochemical detection for the determination of sulfonamides in milk

Abstract This paper deals with the selection of experimental conditions and how the signals obtained in these conditions influence the fitted Partial Least Squares calibration model. The multivariate signals come from a flow analysis system with amperometric detection when determining sulfadiazine, sulfamerazine and sulfamethazine in milk. The solution (carrier plus analyte) was pumped through the system to provide a continuous supply of analyte to the cell. The detector was programmed for a scan mode operation being the multivariate signal the hydrodynamic voltammogram. To obtain an analytical signal of enough analytical quality, the Net Analyte Signal and its standard deviation have been optimised by using an experimental design. The conflicting behaviour of the two responses has been solved by estimating the Pareto-optimal front. The multivariate signals recorded in the optimal conditions found have been calibrated by Partial Least Squares regression and their figures of merit validated according to the criteria established in European Decision 2002/657/EC. In relation to the permitted limit, 100 µg l− 1 in milk, for the total content of sulfonamides established in the Commission Regulation EC no. 281/96 the proposed method has a decision limit of 109.1 µg l− 1 and the capability of detection is 117.9 µg l− 1 for both probability of false non-compliance and of false compliance equal to 5%. A recovery of 86.5% ± 2.4% (n = 5) has been obtained.

[1]  Andrea Marchetti,et al.  Application of N-PLS to gas chromatographic and sensory data of traditional balsamic vinegars of modena , 2006 .

[2]  H. Thompson,et al.  Liquid chromatographic determination of sulfadiazine in salmon by postcolumn derivatization and fluorescence detection. , 1995, Journal of AOAC International.

[3]  M. C. Ortiz,et al.  Capability of detection and three-way data , 2006 .

[4]  D. Kim,et al.  Comparison of separation conditions and ionization methods for the liquid chromatography-mass spectrometric determination of sulfonamides. , 2003, Journal of chromatography. A.

[5]  Suppressing the Temperature Effect in near Infrared Spectroscopy by Using Orthogonal Signal Correction , 2006 .

[6]  Roger Phan-Tan-Luu,et al.  Pharmaceutical Experimental Design , 1998 .

[7]  M. P. Gómez-Carracedo,et al.  Handling complex effects in slurry-sampling-electrothermal atomic absorption spectrometry by multivariate calibration. , 2006, Analytica chimica acta.

[8]  Søren Balling Engelsen,et al.  Quantification of the degree of blockiness in pectins using 1H NMR spectroscopy and chemometrics , 2007 .

[9]  Analysis of interferents by means a D-optimal screening design and calibration using partial least squares regression in the spectrophotometric determination of Cr(VI). , 2007, Talanta.

[10]  Kalyanmoy Deb,et al.  Multi-objective optimization using evolutionary algorithms , 2001, Wiley-Interscience series in systems and optimization.

[11]  K. Esbensen,et al.  Protein heterogeneity in wheat lots using single-seed NIT : A Theory of Sampling (TOS) breakdown of all sampling and analytical errors , 2006 .

[12]  Peter J. Rousseeuw,et al.  Robust regression and outlier detection , 1987 .

[13]  Mathew Muzi Nindi,et al.  Multiresidue determination of sulfonamides in a variety of biological matrices by supported liquid membrane with high pressure liquid chromatography-electrospray mass spectrometry detection. , 2004, Talanta.

[14]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[15]  Luis A. Sarabia,et al.  On Pareto-optimal fronts for deciding about sensitivity and specificity in class-modelling problems , 2005 .

[16]  Luis A. Sarabia,et al.  Capability of detection of an analytical method evaluating false positive and false negative (ISO 11843) with partial least squares , 2003 .

[17]  Rasmus Bro,et al.  Multi-way analysis for investigation of industrial pectin using an analytical liquid dilution system , 2006 .

[18]  Luis A. Sarabia,et al.  Optimisation using a surface response methodology of a system with drift: Application to a flow analysis system with electrochemical detection , 2003 .

[19]  T. S. Thompson,et al.  Determination of sulfonamides in honey by liquid chromatography-tandem mass spectrometry , 2005 .

[20]  William Horwitz,et al.  IUPAC Compendium of Analytical Nomenclature , 1979 .

[21]  V. Reeves Confirmation of multiple sulfonamide residues in bovine milk by gas chromatography-positive chemical ionization mass spectrometry. , 1999, Journal of chromatography. B, Biomedical sciences and applications.

[22]  Luis A. Sarabia,et al.  Vectorial optimization as a methodogical alternative to desirability function , 2006 .

[23]  E. Wang,et al.  Determination of sulfadiazine and sulfamethoxazole by capillary electrophoresis with end-column electrochemical detection. , 1998, The Analyst.

[24]  M. C. Ortiz,et al.  Sensitivity and specificity of PLS-class modelling for five sensory characteristics of dry-cured ham using visible and near infrared spectroscopy , 2006 .

[25]  J. Canselier,et al.  Analysis of chlorinated, sulfochlorinated and sulfonamide derivatives of n-tetradecane by gas chromatography/mass spectrometry. , 2005, Journal of chromatography. A.

[26]  T. Msagati,et al.  Voltammetric detection of sulfonamides at a poly(3-methylthiophene) electrode. , 2002, Talanta.