Effect of instrumental response time in exponential-decay-based cavity ring-down techniques for high reflectivity measurement

Exponential-decay based cavity ring-down (CRD) techniques, such as the pulsed-CRD and continuous-wave (cw) CRD employing a fast switch to shut down the laser beam, are widely used for high reflectivity measurement. In this paper the influence of the response time of the experimental apparatus on the high reflectivity measurement is investigated theoretically and experimentally. Theoretical expressions taking into account the instrumental response time are given for both pulsed- and cw-CRD techniques, respectively. By establishing a simple cw-CRD setup employing detectors with different response time, the influence of the instrumental response time on the high reflectivity measurement is experimentally investigated. By applying a multi-parameter estimation technique to determine simultaneously the cavity decay time and the overall response time of the experimental apparatus via fitting the experimental CRD signal to the corresponding theoretical model, the influence of a long instrumental response time on the reflectivity determination is eliminated. The reflectivities of the cavity mirror measured with detectors with different rise time are in excellent agreement. On the other hand, the error of high reflectivity measurement increases with the increasing rise/fall time of the apparatus in cases that the CRD signals obtained by detectors with relatively slow rise time are simply treated with a single exponential decay fitting procedure.

[1]  G. Berden,et al.  Cavity ring-down spectroscopy: Experimental schemes and applications , 2000 .

[2]  Bincheng Li,et al.  High-reflectivity measurement with a broadband diode laser based cavity ring-down technique , 2007 .

[3]  A. Freedman,et al.  Optical extinction monitor using cw cavity enhanced detection. , 2007, The Review of scientific instruments.

[4]  D. Spencer,et al.  Sensitive measurement of photon lifetime and true reflectances in an optical cavity by a phase-shift method. , 1980, Applied optics.

[5]  Daniele Romanini,et al.  Effects of laser phase noise on the injection of a high-finesse cavity. , 2002, Applied optics.

[6]  J A McKay,et al.  Development of laser mirrors of very high reflectivity using the cavity-attenuated phase-shift method. , 1981, Applied optics.

[7]  D. Romanini,et al.  CW cavity ring down spectroscopy , 1997 .

[8]  Xiong Sheng-ming,et al.  Analysis of reflectivity measurement by cavity ring-down spectroscopy , 2005 .

[9]  Bincheng Li,et al.  Diode laser based continuous-wave cavity ring-down technique for high reflectivity measurement , 2007, International Symposium on Advanced Optical Manufacturing and Testing Technologies (AOMATT).

[10]  Richard N. Zare,et al.  Cavity ring-down spectroscopy for quantitative absorption measurements , 1995 .

[11]  L.H.J.F. Beckmann,et al.  Optical systems for high-power laser applications: principles and design aspects , 1995 .

[12]  P. Elleaume,et al.  Diagnostic techniques and UV-induced degradation of the mirrors used in the Orsay storage ring free-electron laser. , 1985, Applied optics.

[13]  Joshua R. Smith,et al.  LIGO: the Laser Interferometer Gravitational-Wave Observatory , 1992, Science.

[14]  D. Z. Anderson,et al.  Mirror reflectometer based on optical cavity decay time. , 1984, Applied optics.

[15]  Vincent Loriette Test of mirror pair reflectivity coefficient equality and homogeneity for interferometric gravitational wave detectors , 1995 .

[16]  N Uehara,et al.  Ultralow-loss mirror of the parts-in-10(6) level at 1064 nm. , 1995, Optics letters.

[17]  G. Rempe,et al.  Measurement of ultralow losses in an optical interferometer. , 1992, Optics letters.