Evaluation of an algorithm for arterial lumen diameter measurements by means of ultrasound

We have developed an algorithm for arterial luminal diameter measurement by means of ultrasound and evaluated the algorithm on agar vessel phantoms and in vivo. The algorithm utilises relative threshold detection on the inner slopes of the arterial walls before the resolution is improved by solving the equation of a straight line between the samples around the threshold value. Further, correction distances added to compensate for the underestimation when using the inner slopes were found to be 304 μm for the near wall and 415 μm for the far wall. The measured mean diameters of ten consecutive images of 3-, 6- and 9-mm phantoms were 3,006 μm (SD 4), 5,918 μm (SD 1) and 8,936 μm (SD 2), respectively. The mean differences between the images were 0.19, 0.04 and 0.37 μm, respectively. In vivo, the intra- and inter-observer variabilities were −64 μm (2SD 358) and −57 μm (2SD 366), respectively.

[1]  P. Tortoli,et al.  Accurate Doppler angle estimation for vector flow measurements , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  R. A. Banjavic,et al.  A new ultrasound tissue-equivalent material. , 1980, Radiology.

[3]  Carl de Boor,et al.  A Practical Guide to Splines , 1978, Applied Mathematical Sciences.

[4]  P Pignoli,et al.  Intimal plus medial thickness of the arterial wall: a direct measurement with ultrasound imaging. , 1986, Circulation.

[5]  Alessandro C Rossi,et al.  Nonlinear processing in B-mode ultrasound affects carotid diameter assessment. , 2009, Ultrasound in medicine & biology.

[6]  B. Sonesson,et al.  Increased arterial stiffness in women, but not in men, with IDDM , 1995, Diabetologia.

[7]  R. Armentano,et al.  Experimental and clinical validation of arterial diameter waveform and intimal media thickness obtained from B-mode ultrasound image processing. , 1999, Ultrasound in medicine & biology.

[8]  N. Santhiyakumari,et al.  Detection of the intima and media layer thickness of ultrasound common carotid artery image using efficient active contour segmentation technique , 2011, Medical & Biological Engineering & Computing.

[9]  T Gustavsson,et al.  Ultrasound measurement of wall thickness in the carotid artery: fundamental principles and description of a computerized analysing system. , 1991, Clinical physiology.

[10]  Lysle H. Peterson,et al.  Mechanical Properties of Arteries in Vivo , 1960 .

[11]  Å. Ahlgren,et al.  Evaluation of an ultrasonic echo-tracking method for measurements of arterial wall movements in two dimensions , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  F Beux,et al.  Automatic evaluation of arterial diameter variation from vascular echographic images. , 2001, Ultrasound in medicine & biology.

[13]  V R Newey,et al.  Online artery diameter measurement in ultrasound images using artificial neural networks. , 2002, Ultrasound in medicine & biology.

[14]  P R Hoskins,et al.  Blood vessel diameter measurement by ultrasound. , 1993, Physiological measurement.

[15]  Takashi Okada,et al.  Clinical usefulness of wave intensity analysis , 2009, Medical & Biological Engineering & Computing.

[16]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[17]  W. Karl,et al.  New methods for arterial diameter measurement from B-mode images. , 1996, Ultrasound in medicine & biology.

[18]  Tomas Jansson,et al.  Longitudinal movements and resulting shear strain of the arterial wall. , 2006, American journal of physiology. Heart and circulatory physiology.

[19]  Shmuel Einav,et al.  Cardiovascular disease management: the need for better diagnostics , 2008, Medical & Biological Engineering & Computing.

[20]  R H Selzer,et al.  Evaluation of computerized edge tracking for quantifying intima-media thickness of the common carotid artery from B-mode ultrasound images. , 1994, Atherosclerosis.

[21]  Quan Liang,et al.  A dynamic programming procedure for automated ultrasonic measurement of the carotid artery , 1994, Computers in Cardiology 1994.

[22]  O. Wiklund,et al.  Frontiers in cardiovascular science. Quantitative measurements of atherosclerotic manifestations in humans. , 1992, Arteriosclerosis and thrombosis : a journal of vascular biology.

[23]  Y. Yokota,et al.  Estimation of carotid diameter with heartbeat on longitudinal B-mode ultrasonic images , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[24]  S Sasayama,et al.  Non-invasive assessment of the age related changes in stiffness of major branches of the human arteries. , 1987, Cardiovascular research.

[25]  Christos P. Loizou,et al.  Snakes based segmentation of the common carotid artery intima media , 2007, Medical & Biological Engineering & Computing.

[26]  T. Loupas,et al.  Arterial pulse wave velocity with tissue Doppler imaging. , 2002, Ultrasound in medicine & biology.

[27]  Magnus Cinthio Ultrasonic Methods for 2D Arterial Wall Movement Measurements , 2004 .

[28]  R. S. D. Wahida Banu,et al.  A non-invasive study of alterations of the carotid artery with age using ultrasound images , 2006, Medical and Biological Engineering and Computing.