A Multi-Functional Physiological Hybrid-Sensing E-Skin Integrated Interface for Wearable IoT Applications

This paper presents a flexible multi-functional physiological sensing system that provides multiple noise-immune readout architectures and hybrid-sensing capability with an analog pre-processing scheme. The proposed multi-functional system is designed to support five physiological detection methodologies of piezo-resistive, pyro-resistive, electro-metric, opto-metric and their hybrid, utilizing an in-house multi-functional e-skin device, in-house flexible electrodes and a LED-photodiode pair. For their functional verification, eight representative physiological detection capabilities were demonstrated using wearable device prototypes. Especially, the hybrid detection method includes an innovative continuous measurement of blood pressure (BP) while most previous wearable devices are not ready for it. Moreover, for effective implementation in the form of the wearable device, post-processing burden of the hybrid method was much reduced by integrating a proposed analog pre-processing scheme, where only simple counting process and calibration remain to estimate the BP. This multi-functional sensor readout circuits and their hybrid-sensing interface are fully integrated into a single readout integrated circuit (ROIC), which is designed to implement three readout paths: two electrometric readout paths and one impedometric readout path. For noise-immune detection of the e-skin sensor, a pseudo-differential front-end with a ripple reduction loop is proposed in the impedometric readout path, and also state-of-the-art body-oriented noise reduction techniques are adopted for the electrometric readout path. The ROIC is fabricated in a CMOS process and in-house e-skin devices and flexible electrodes are also fabricated.

[1]  Refet Firat Yazicioglu,et al.  A 160μW 8-channel active electrode system for EEG monitoring , 2011, 2011 IEEE International Solid-State Circuits Conference.

[2]  Yong Lian,et al.  Towards a Continuous Non-Invasive Cuffless Blood Pressure Monitoring System Using PPG: Systems and Circuits Review , 2018, IEEE Circuits and Systems Magazine.

[3]  Madhuchhanda Mitra,et al.  ECG Acquisition and Automated Remote Processing , 2013 .

[4]  Hanfeng Wang,et al.  A Low-Power Wireless Piezoelectric Sensor-Based Respiration Monitoring System Realized in CMOS Process , 2017, IEEE Sensors Journal.

[5]  Refet Firat Yazicioglu,et al.  A $160~\mu {\rm W}$ 8-Channel Active Electrode System for EEG Monitoring , 2011, IEEE Transactions on Biomedical Circuits and Systems.

[6]  Carmen C. Y. Poon,et al.  Flexible Piezoresistive Sensor Patch Enabling Ultralow Power Cuffless Blood Pressure Measurement , 2016 .

[7]  Dae Jung Kim,et al.  A Wireless ExG Interface for Patch-Type ECG Holter and EMG-Controlled Robot Hand , 2017, Sensors.

[8]  Refet Firat Yazicioglu,et al.  Active Electrodes for Wearable EEG Acquisition: Review and Electronics Design Methodology , 2017, IEEE Reviews in Biomedical Engineering.

[9]  Jonghwa Park,et al.  A Triple-Mode Flexible E-Skin Sensor Interface for Multi-Purpose Wearable Applications , 2017, Sensors.

[10]  Seung Bae Lee,et al.  Multi-modal smart bio-sensing SoC platform with >80dB SNR 35µA PPG RX chain , 2016, 2016 IEEE Symposium on VLSI Circuits (VLSI-Circuits).

[11]  M. Mialich,et al.  Analysis of Body Composition: A Critical Review of the Use of Bioelectrical Impedance Analysis , 2014 .

[12]  Jun Zhou,et al.  A 457 nW Near-Threshold Cognitive Multi-Functional ECG Processor for Long-Term Cardiac Monitoring , 2014, IEEE Journal of Solid-State Circuits.

[13]  Yonggang Huang,et al.  Highly flexible, wearable, and disposable cardiac biosensors for remote and ambulatory monitoring , 2018, npj Digital Medicine.

[14]  Shusuke Yoshimoto,et al.  Wearable pulse wave velocity sensor using flexible piezoelectric film array , 2017, 2017 IEEE Biomedical Circuits and Systems Conference (BioCAS).

[15]  Gabor C. Temes,et al.  Circuit techniques for reducing the effects of op-amp imperfections: autozeroing, correlated double sampling, and chopper stabilization , 1996, Proc. IEEE.

[16]  Hoi-Jun Yoo,et al.  27.2 A 25.2mW EEG-NIRS multimodal SoC for accurate anesthesia depth monitoring , 2017, 2017 IEEE International Solid-State Circuits Conference (ISSCC).

[17]  L Tian,et al.  Wearable sensors: modalities, challenges, and prospects. , 2018, Lab on a chip.

[18]  Jonghwa Park,et al.  Fingertip skin–inspired microstructured ferroelectric skins discriminate static/dynamic pressure and temperature stimuli , 2015, Science Advances.

[19]  Franklin Bien,et al.  Tissue-Informative Mechanism for Wearable Non-invasive Continuous Blood Pressure Monitoring , 2014, Scientific Reports.

[20]  Shuvo Roy,et al.  A Wearable Patch to Enable Long-Term Monitoring of Environmental, Activity and Hemodynamics Variables , 2016, IEEE Transactions on Biomedical Circuits and Systems.

[21]  A. Thomasset,et al.  Fat-free mass estimation by the two-electrode impedance method. , 1990, The American journal of clinical nutrition.

[22]  Refet Firat Yazicioglu,et al.  A Multi(bio)sensor Acquisition System With Integrated Processor, Power Management, $8 \times 8$ LED Drivers, and Simultaneously Synchronized ECG, BIO-Z, GSR, and Two PPG Readouts , 2016, IEEE Journal of Solid-State Circuits.

[23]  Seungwook Lee,et al.  A Three-Step Resolution-Reconfigurable Hazardous Multi-Gas Sensor Interface for Wireless Air-Quality Monitoring Applications , 2018, Sensors.

[24]  Kofi A. A. Makinwa,et al.  A 1.8 $\mu$ W 60 nV$/\surd$ Hz Capacitively-Coupled Chopper Instrumentation Amplifier in 65 nm CMOS for Wireless Sensor Nodes , 2011, IEEE Journal of Solid-State Circuits.

[25]  Refet Firat Yazicioglu,et al.  A 13 $\mu {\rm A}$ Analog Signal Processing IC for Accurate Recognition of Multiple Intra-Cardiac Signals , 2013, IEEE Transactions on Biomedical Circuits and Systems.

[26]  Jonghwa Park,et al.  Large-Area Cross-Aligned Silver Nanowire Electrodes for Flexible, Transparent, and Force-Sensitive Mechanochromic Touch Screens. , 2017, ACS nano.

[27]  Mario Konijnenburg,et al.  A 36μW reconfigurable analog front-end IC for multimodal vital signs monitoring , 2017, 2017 Symposium on VLSI Circuits.

[28]  Zhong Lin Wang,et al.  Skin-inspired highly stretchable and conformable matrix networks for multifunctional sensing , 2018, Nature Communications.

[29]  Hariprasad Chandrakumar,et al.  A High Dynamic-Range Neural Recording Chopper Amplifier for Simultaneous Neural Recording and Stimulation , 2017, IEEE Journal of Solid-State Circuits.

[30]  Hyunki Kim,et al.  22.3 A 141µW sensor SoC on OLED/OPD substrate for SpO2/ExG monitoring sticker , 2016, 2016 IEEE International Solid-State Circuits Conference (ISSCC).

[31]  Jaehyouk Choi,et al.  Dual-mode wide-range linear CMOS interface circuit for resistive sensors , 2014 .