Conjugate heat and mass transfer in a total heat exchanger with cross-corrugated triangular ducts and one-step made asymmetric membranes

Abstract Membrane-based total heat exchanger is a device to recover both sensible heat and moisture from exhaust air stream from a building. Heat and mass transfer intensification has been undertaken by using a structure of cross-corrugated triangular ducts. To further intensify moisture transfer, recently developed membranes-one step made asymmetric membranes, are used as the exchanger materials. Conjugate heat and mass transfer under transitional flow regime in this total heat exchanger are investigated. Contrary to the traditional methods of assuming a uniform temperature (concentration) or a uniform heat flux (mass flux) boundary condition, in this study, the real boundary conditions on the exchanger surfaces are obtained by the numerical solution of the coupled equations that govern the transfer of momentum, energy and moisture in the two air streams and in the membrane materials. The naturally formed heat and mass boundary conditions are then used to calculate the local and mean Nusselt and Sherwood numbers along the exchanger ducts, in the heat and mass developing regions. The data are compared with those results under uniform temperature (concentration) and uniform heat flux (mass flux) boundary conditions, for cross-corrugated triangular ducts with typical duct apex angles of 60° and 90°.

[1]  Y. Tsai,et al.  Investigations of the pressure drop and flow distribution in a chevron-type plate heat exchanger , 2009 .

[2]  Guangming Chen,et al.  A numerical and experimental study of chevron, corrugated-plate heat exchangers , 2010 .

[3]  Li-Zhi Zhang,et al.  Conjugate heat and mass transfer in a cross-flow hollow fiber membrane contactor for liquid desiccant air dehumidification , 2012 .

[4]  J. Niu,et al.  Effectiveness Correlations for Heat and Moisture Transfer Processes in an Enthalpy Exchanger With Membrane Cores , 2002 .

[5]  Yi Jiang,et al.  HEAT AND MASS TRANSFER IN A MEMBRANE-BASED ENERGY RECOVERY VENTILATOR , 1999 .

[6]  Li-Zhi Zhang,et al.  Turbulent three-dimensional air flow and heat transfer in a cross-corrugated triangular duct , 2005 .

[7]  Gongnan Xie,et al.  Experimental Study and Genetic-Algorithm-Based Correlation on Pressure Drop and Heat Transfer Performances of a Cross-Corrugated Primary Surface Heat Exchanger , 2009 .

[8]  Nimai Kumar Mitra,et al.  NUMERICAL INVESTIGATION OF FLOW FIELD AND HEAT TRANSFER IN CROSS-CORRUGATED DUCTS , 1999 .

[9]  Zhenyu Liu,et al.  Steady-State and Transient Investigation of the Primary Surface Recuperator for Microturbines , 2013 .

[10]  Li-Zhi Zhang,et al.  Progress on heat and moisture recovery with membranes: From fundamentals to engineering applications ☆ , 2012 .

[11]  P. Lettieri,et al.  An introduction to heat transfer , 2007 .

[12]  Li-Zhi Zhang,et al.  One-step fabrication and analysis of an asymmetric cellulose acetate membrane for heat and moisture recovery , 2011 .

[13]  E. Cussler,et al.  Membrane Modules for Building Ventilation , 2002 .

[14]  J. Stasiek,et al.  Experimental studies of heat transfer and fluid flow across corrugated-undulated heat exchanger surfaces , 1998 .

[15]  Li-Zhi Zhang,et al.  Numerical Study of Periodically Fully Developed Flow and Heat Transfer in Cross-Corrugated Triangular Channels in Transitional Flow Regime , 2005 .

[16]  Li-Zhi Zhang,et al.  Convective heat transfer in cross-corrugated triangular ducts under uniform heat flux boundary conditions , 2011 .

[17]  Sumanta Acharya,et al.  Two-Equation Turbulence Modeling for Impeller Stirred Tanks , 2001 .

[18]  J. Niu,et al.  Laminar fluid flow and mass transfer in a standard field and laboratory emission cell , 2003 .

[19]  S. Kabelac,et al.  Investigation of local heat transfer coefficients in plate heat exchangers with temperature oscillation IR thermography and CFD , 2010 .

[20]  Li-Zhi Zhang,et al.  Heat and mass transfer in a cross-flow membrane-based enthalpy exchanger under naturally formed boundary conditions , 2007 .

[21]  D. B. Spalding,et al.  Concentration fluctuations in a round turbulent free jet , 1971 .

[22]  S. Ergin,et al.  NUMERICAL STUDY OF PERIODIC TURBULENT FLOW THROUGH A CORRUGATED DUCT , 2001 .

[23]  D. Che,et al.  Influence of Corrugation Profile on the Thermalhydraulic Performance of Cross-Corrugated Plates , 2011 .

[24]  R. Amano,et al.  Application of non-linear k–ω model to a turbulent flow inside a sharp U-bend , 2000 .

[25]  Li-Zhi Zhang,et al.  Coupled heat and mass transfer in a counter flow hollow fiber membrane module for air humidification , 2011 .

[26]  M. Collins,et al.  Investigation of flow and heat transfer in corrugated passages—II. Numerical simulations , 1996 .

[27]  W. M. Taama,et al.  Mass transfer characteristics of corrugated surfaces , 2004 .

[28]  W. Focke,et al.  The effect of the corrugation inclination angle on the thermohydraulic performance of plate heat exchangers , 1985 .

[29]  M. Collins,et al.  Investigation of flow and heat transfer in corrugated passages—I. Experimental results , 1996 .

[30]  Minlin Yang,et al.  Conjugate transport phenomena in a counter flow hollow fiber membrane tube bank: Effects of the fiber-to-fiber interactions , 2013 .

[31]  Li-Zhi Zhang,et al.  Laminar flow and heat transfer in plate-fin triangular ducts in thermally developing entry region , 2007 .

[32]  Roshan Jeet Jee Jachuck,et al.  Determination of mass transfer coefficient of a cross-corrugated membrane reactor by the limiting-current technique , 2001 .

[33]  Xin Wang,et al.  Evaluation of CFD Simulation using RANS Turbulence Models for Building Effects on Pollutant Dispersion , 2006 .