Reproducibility of Optic Disk Topographic Measurements with the Topcon ImageNet and the Heidelberg Retina Tomograph

Objective: To compare the reproducibility of optic disk measurements provided by an image analyzer and a scanning laser tomograph. Methods: Ten images of the same eye of 10 normal volunteers were taken with the Heidelberg Retina Tomograph and with the Topcon ImageNet. Intraclass correlation coefficient (ICC) and coefficient of variation (CV) were used to evaluate the reproducibility of the measurements. Results: Eleven parameters were analyzed with the Topcon ImageNet. Six parameters (55%) had ICC greater than 90%. Four parameters (36%) had CV less than 10%. Twelve parameters were evaluated with the Heidelberg Retina Tomograph. Nine parameters (75%) had ICC over 90%. Nine parameters (75%) had CV less than 10%. Conclusion: Both systems provided reproducible data. The optic disk parameters provided by the Heidelberg Retina Tomograph had a better reproducibility than those obtained from the Topcon ImageNet.

[1]  T. Cornsweet,et al.  Reliability of optic disk topographic measurements recorded with a video-ophthalmograph. , 1984, American journal of ophthalmology.

[2]  R. Klein,et al.  Optic disc cupping as clinically estimated from photographs. , 1987, Ophthalmology.

[3]  R Varma,et al.  Agreement between clinicians and an image analyzer in estimating cup-to-disc ratios. , 1989, Archives of ophthalmology.

[4]  M. Wax,et al.  Variability and reproducibility of optic disk topographic measurements with the Rodenstock Optic Nerve Head Analyzer. , 1988, American journal of ophthalmology.

[5]  A. Sommer,et al.  Intraobserver and interobserver agreement in measurement of optic disc characteristics. , 1988, Ophthalmology.

[6]  M Schulzer,et al.  Reproducibility of topographic parameters obtained with the heidelberg retina tomograph. , 1993, Journal of glaucoma.

[7]  J. T. Schwartz Methodologic differences and measurement of cup-disc ratio: an epidemiologic assessment. , 1976, Archives of ophthalmology.

[8]  I. Scott,et al.  Expert agreement in evaluating the optic disc for glaucoma. , 1992, Ophthalmology.

[9]  R N Weinreb,et al.  Reproducibility of optic nerve head topography measurements in eyes with undilated pupils. , 1993, Journal of glaucoma.

[10]  L. Dandona,et al.  Variability of depth measurements of the optic nerve head and peripapillary retina with computerized image analysis. , 1989, Archives of ophthalmology.

[11]  G A Cioffi,et al.  Confocal laser scanning ophthalmoscope. Reproducibility of optic nerve head topographic measurements with the confocal laser scanning ophthalmoscope. , 1993, Ophthalmology.

[12]  P. Lichter Variability of expert observers in evaluating the optic disc. , 1976, Transactions of the American Ophthalmological Society.

[13]  M. B. Shields,et al.  Reproducibility of topographic measurements with the optic nerve head analyzer. , 1987, American journal of ophthalmology.

[14]  U Klingbeil,et al.  Reproducibility of optic disc measurements with computerized analysis of stereoscopic video images. , 1986, Archives of ophthalmology.

[15]  R N Weinreb,et al.  Reproducibility of topographic measurements of the normal and glaucomatous optic nerve head with the laser tomographic scanner. , 1991, American journal of ophthalmology.

[16]  R N Weinreb,et al.  Effect of repetitive imaging on topographic measurements of the optic nerve head. , 1993, Archives of ophthalmology.

[17]  B. J. Winer Statistical Principles in Experimental Design , 1992 .