[Wear and Roughness of Bearing Surface in Retrieved Polyethylene Bicon-Plus Cups].

PURPOSE OF THE STUDY By 7th December 2016, 4,755 Bicon-Plus cups in total were implanted in the Czech Republic. Some of them have been continuously re-operated, while the most frequent reason of failure is polyethylene wear and aseptic loosening. The present study is focused on surface analysis of retrieved polyethylene Bicon-Plus cups and the determination of the roughness of their bearing surfaces. MATERIAL AND METHODS In this study, we had 13 high molecular weight polyethylene cups with the average time in situ of 8.11 years (3.6-13.7, SD 3.2) before the retrieval. The study population was composed of 3 men, 10 women, with the mean age of 53.31 years. An optical scanning method, based on the principle of active triangulation, was used to determine wear rate. The rate of wear was identified by means of an obtained scan subsequently processed with the use of the GOM Inspect software. The roughness of surfaces was analysed with the application of Contour GT-X8 profiler using the principle of phase shifting interferometry. Measurements of surface topography of the retrieved cups were performed on the entire bearing surfaces. For the individual surface changes, a typical range of surface roughness, describing the particular wear character, was determined. By means of morphology analysis of the tested implants, three areas were identified: unworn area; area representing the worn part of the cup; and the area roughened by parallel grooving. The total surface roughness was evaluated as an arithmetic mean of the measured values. Subsequently, the values were sorted based on frequency and were classified into categories defining the particular wear mechanisms. RESULTS Wear rate of the retrieved acetabular cups was evaluated based on the wear direction vector and the size of linear wear. The average linear wear was equal to 0.13 mm/year (ranging from 0.26 to 2.29 mm/year), and the mean value of total volumetric material loss was 44.37 mm3/year (the range being from 51.80 to 1,119.7 mm3/year). Using the optical profilometer, a map of roughness distribution of the individual cups was obtained. For each implant, 76 values of roughness were evaluated. With the respect to average roughness, the samples were sorted to various categories describing: surface polishing; abrasiveadhesive wear; surfaces with preserved grooving; substantial plastic deformation. DISCUSSION The results clearly showed an increase of wear depending on implant survival; however, the tendency is not linear. This fact can be attributed to a larger amount of abrasive particles, causing an increase of wear or occurrence of surface wear in terms of micro cracks and oxidation degradation of polyethylene. This study indicates that geometry, positioning, and cup alignment during the implantation have a fundamental impact on the cup durability. Further correlation, which was observed in the case of the cup with prevailing roughness in the range from 0.1 to 0.3 μm, is a relatively wide wear vector angle determined with the use of the optical method. Considering the implants with the longest survival time with no loosening of the acetabular cup, the mean angle of direction vector was 56.8° (SD 2.1°). CONCLUSIONS The present study provides the results of morphology analysis of the retrieved Bicon-Plus cups. In general, relatively high wear rate, mainly of abrasive-adhesive character was identified. The dependence between wear and implant in situ longevity was not clearly linear, which suggests the influence of other parameters on the polyethylene wear rate. An important role of implant positioning on survival was also revealed. Moreover, it seems that it can be a more important parameter than the characteristics of the patient. Key words: total hip arthroplasty, Bicon-Plus cup, retrieval analysis, surface analysis, wear measurement, roughness, deformation, survivorship.

[1]  M. Hartl,et al.  Characteristics of synovial fluid required for optimization of lubrication fluid for biotribological experiments. , 2017, Journal of biomedical materials research. Part B, Applied biomaterials.

[2]  Martin Hartl,et al.  Wear Analysis of Extracted Polyethylene Acetabular Cups Using a 3D Optical Scanner , 2017 .

[3]  I. Křupka,et al.  Lubrication within hip replacements - Implication for ceramic-on-hard bearing couples. , 2016, Journal of the mechanical behavior of biomedical materials.

[4]  A. F. Barnaart,et al.  Outcome of the Cementless Zweymüller BICON-PLUS Cup and SL-PLUS Stem in the Very Elderly Individuals , 2016, Geriatric orthopaedic surgery & rehabilitation.

[5]  M. Šlouf,et al.  [Analysis of Oxidative Damage to Components Removed from Beznoska/Poldi Total Hip Replacements]. , 2016, Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca.

[6]  I. Křupka,et al.  The effect of lubricant constituents on lubrication mechanisms in hip joint replacements. , 2016, Journal of the mechanical behavior of biomedical materials.

[7]  Carlos A. Achete,et al.  Multi-Scale Evaluation of Wear in UHMWPE-Metal Hip Implants Tested in a hip Joint Simulator , 2015 .

[8]  S. Bulstra,et al.  Survival, Clinical and Radiological Outcome of the Zweymüller SL/Bicon-Plus Total Hip Arthroplasty: A 15-Year Follow-up Study , 2015, Hip international : the journal of clinical and experimental research on hip pathology and therapy.

[9]  I. Křupka,et al.  Visualization of lubricating films between artificial head and cup with respect to real geometry , 2015 .

[10]  David Paloušek,et al.  Effect of matte coating on 3D optical measurement accuracy , 2015 .

[11]  I. Křupka,et al.  [Determination of a Friction Coefficient for THA Bearing Couples]. , 2015, Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca.

[12]  M. Parkes,et al.  The effect of buffer solution choice on protein adsorption and lubrication , 2014 .

[13]  I. Milošev,et al.  A comparative study of four bearing couples of the same acetabular and femoral component: a mean follow-up of 11.5 years. , 2014, The Journal of arthroplasty.

[14]  J. Flynn,et al.  Body mass index and acetabular component position in total hip arthroplasty , 2013, ANZ journal of surgery.

[15]  I. Křupka,et al.  Study of film formation in bovine serum lubricated contacts under rolling/sliding conditions , 2013 .

[16]  R. Trebše,et al.  Comparison of ten-year survivorship of hip prostheses with use of conventional polyethylene, metal-on-metal, or ceramic-on-ceramic bearings. , 2012, The Journal of bone and joint surgery. American volume.

[17]  Lisa A. Pruitt,et al.  Mechanics of biomaterials: Fundamental principles for implant design , 2011 .

[18]  P. Korovessis,et al.  High medium-term survivorship and durability of Zweymüller-Plus total hip arthroplasty , 2011, Archives of Orthopaedic and Trauma Surgery.

[19]  A. Sosna,et al.  Distribution of polyethylene wear particles and bone fragments in periprosthetic tissue around total hip joint replacements. , 2010, Acta biomaterialia.

[20]  M. Hrabovsky,et al.  Optical 3D methods for measurement of prosthetic wear of total hip arthroplasty: principles, verification and results. , 2009, Optics express.

[21]  Robert B. Bourne,et al.  Acetabular Polyethylene Wear and Acetabular Inclination and Femoral Offset , 2009, Clinical orthopaedics and related research.

[22]  Claire L. Brockett,et al.  The influence of clearance on friction, lubrication and squeaking in large diameter metal-on-metal hip replacements , 2008, Journal of materials science. Materials in medicine.

[23]  L. Dorr,et al.  The influence of acetabular component position on wear in total hip arthroplasty. , 2008, The Journal of arthroplasty.

[24]  K. Zweymüller,et al.  Good Stability and Minimal Osteolysis with a Biconical Threaded Cup at 10 Years , 2007, Clinical orthopaedics and related research.

[25]  Ivana Cechova,et al.  Wear measurement of retrieved polyethylene ABG 1 cups by universal-type measuring microscope and X-ray methods. , 2006, Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia.

[26]  Z. Cichý [Treatment of dysplastic acetabulum using total hip arthroplasty: our intermediate-term results]. , 2006, Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca.

[27]  T. Pavelka,et al.  [Hip joint arthroplasty following surgical treatment of acetabular fracture]. , 2006, Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca.

[28]  Rami K Korhonen,et al.  The effect of geometry and abduction angle on the stresses in cemented UHMWPE acetabular cups – finite element simulations and experimental tests , 2005, Biomedical engineering online.

[29]  Duncan Dowson,et al.  A hip joint simulator study of the performance of metal-on-metal joints: Part II: design. , 2004, The Journal of arthroplasty.

[30]  A. Edidin,et al.  Assessment of Surface Roughness and Waviness Using White Light Interferometry for Short-Term Implanted, Highly Crosslinked Acetabular Components , 2004 .

[31]  Shantanu Patil,et al.  Polyethylene Wear and Acetabular Component Orientation , 2003, The Journal of bone and joint surgery. American volume.

[32]  A. Edidin,et al.  A literature review of the association between wear rate and osteolysis in total hip arthroplasty. , 2002, The Journal of arthroplasty.

[33]  Clare M. Rimnac,et al.  Mechanical behavior, wear surface morphology, and clinical performance of UHMWPE acetabular components after 10 years of implantation , 2001 .

[34]  P. Dungl,et al.  [Medium-term Experience with Zweymüller's Bicon Plus Cup in the Treatment of Postdysplastic Osteoarthritits of the Hip Joint.]. , 2000, Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca.