2D arbitrary shape‐selective excitation summed spectroscopy (ASSESS)

Conventional single‐voxel localization for MR spectroscopy (MRS) is restricted to selecting only rectangular‐shaped regions of interest (ROIs). The complexity of tissue shapes of interest and the desire to maximize the signal‐to‐noise ratio (SNR) while minimizing partial‐volume effects require more sophisticated localization techniques. A group of spatially selective RF pulses are proposed in this work for the measurement of spectra from regions of arbitrary shape based on using a radial trajectory in k‐space. Utilizing a single k‐line per excitation results in a broad spectroscopic bandwidth. However, spatial localization accuracy is compromised for nutation angles > 10° because of the small‐tip‐angle approximation of the Bloch equations. By interleaving multiple radial k‐lines per excitation with nonselective refocusing pulses, one can achieve accurate localization for nutation angles up to 90° while simultaneously maintaining the spectral bandwidth. The technique is described and compared with existing localization methods, and in vivo results are demonstrated. Magn Reson Med 58:19–26, 2007. © 2007 Wiley‐Liss, Inc.

[1]  Albert Macovski,et al.  A linear class of large-tip-angle selective excitation pulses , 1989 .

[2]  R Gruetter,et al.  Automatic, localized in Vivo adjustment of all first‐and second‐order shim coils , 1993, Magnetic resonance in medicine.

[3]  D Matthaei,et al.  1H NMR chemical shift selective (CHESS) imaging. , 1985, Physics in medicine and biology.

[4]  J. Pauly,et al.  Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm [NMR imaging]. , 1991, IEEE transactions on medical imaging.

[5]  P Börnert,et al.  On the performance and accuracy of 2D navigator pulses. , 1999, Magnetic resonance imaging.

[6]  L P Panych,et al.  Selection of high‐definition 2D virtual profiles with multiple RF pulse excitations along interleaved echo‐planar k‐space trajectories , 1999, Magnetic resonance in medicine.

[7]  Thomas H. Mareci,et al.  Selective inversion radiofrequency pulses by optimal control , 1986 .

[8]  Jullie W Pan,et al.  1H and 31P Spectroscopic Imaging of Epilepsy: Spectroscopic and Histologic Correlations , 2004, Epilepsia.

[9]  P. Bottomley Spatial Localization in NMR Spectroscopy in Vivo , 1987, Annals of the New York Academy of Sciences.

[10]  Douglas C Noll,et al.  Iterative RF pulse design for multidimensional, small‐tip‐angle selective excitation , 2005, Magnetic resonance in medicine.

[11]  C J Hardy,et al.  31P Spectroscopic localization using pinwheel NMR excitation pulses , 1991, Magnetic resonance in medicine.

[12]  S. Macura,et al.  Broad-band NMR with a high spectral and spatial resolution , 2002 .

[13]  V A Stenger,et al.  Three‐dimensional tailored RF pulses for the reduction of susceptibility artifacts in T*2‐weighted functional MRI , 2000, Magnetic resonance in medicine.

[14]  Mark Henkelman,et al.  Spatial localization combining projection presaturation with a two‐dimensional excitation pulse , 1998, Magnetic resonance in medicine.

[15]  J Hennig,et al.  RARE imaging: A fast imaging method for clinical MR , 1986, Magnetic resonance in medicine.

[16]  K. Uğurbil,et al.  NMR chemical shift imaging in three dimensions. , 1982, Proceedings of the National Academy of Sciences of the United States of America.

[17]  Yudong Zhu,et al.  Parallel excitation with an array of transmit coils , 2004, Magnetic resonance in medicine.

[18]  Roger J. Ordidge,et al.  Image-selected in Vivo spectroscopy (ISIS). A new technique for spatially selective nmr spectroscopy , 1986 .

[19]  J. Pauly,et al.  One‐shot spatially resolved velocity imaging , 1998, Magnetic resonance in medicine.

[20]  Pruessmann,et al.  RF pulse concatenation for spatially selective inversion , 2000, Journal of magnetic resonance.

[21]  Jens Frahm,et al.  Two‐dimensional spatially‐selective RF excitation pulses in echo‐planar imaging , 2002, Magnetic resonance in medicine.

[22]  J. Ra,et al.  Radial scanning technique for volume selective 31P spectroscopy , 1992, Magnetic resonance in medicine.

[23]  Peter Börnert,et al.  On spatially selective RF excitation and its analogy with spiral MR image acquisition , 1998, Magnetic Resonance Materials in Physics, Biology and Medicine.

[24]  P. Börnert,et al.  Transmit SENSE , 2003, Magnetic resonance in medicine.

[25]  J. Leigh,et al.  The synthesis of pulse sequences yielding arbitrary magnetization vectors , 1989, Magnetic resonance in medicine.

[26]  Christopher J. Hardy,et al.  Correcting for nonuniform k-space sampling in two-dimensional NMR selective excitation , 1990 .

[27]  P Börnert,et al.  Curved slice imaging , 1996, Magnetic resonance in medicine.

[28]  Christopher J. Hardy,et al.  Spatial localization in two dimensions using NMR designer pulses , 1989 .

[29]  KLAUS-DIETMARMERFSOLDT Jensfrahm Localized Proton Spectroscopy Using Stimulated Echoes , 2004 .

[30]  J M Pauly,et al.  Design of practical T2‐selective RF excitation (TELEX) pulses , 1998, Magnetic resonance in medicine.

[31]  R. Constable,et al.  Measurement and correction of transmitter and receiver induced nonuniformities in vivo , 2005, Magnetic resonance in medicine.

[32]  Peter Jezzard,et al.  Selective arterial spin labeling (SASL): Perfusion territory mapping of selected feeding arteries tagged using two‐dimensional radiofrequency pulses , 2003, Magnetic resonance in medicine.

[33]  J. Gore,et al.  Calculation of RF Peak Power for 2D Arbitrary Shape Excitation in MRI , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.