Design of a variable temperature scanning force microscope.

We have developed the variable temperature scanning force microscope capable of performing both magnetic resonance force microscopy (MRFM) and magnetic force microscopy (MFM) measurements in the temperature range between 5 and 300 K. Modular design, large scanning area, and interferometric detection of the cantilever deflection make it a sensitive, easy to operate, and reliable instrument suitable for studies of the dynamic and static magnetization in various systems. We have verified the performance of the microscope by imaging vortices in a Nb thin film in the MFM mode of operation. MRFM spectra in a diphenyl-picryl-hydrazyl film were recorded to evaluate the MRFM mode of operation.

[1]  Millikelvin scanned probe for measurement of nanostructures , 2003, cond-mat/0311224.

[2]  H. Güntherodt,et al.  Low temperature magnetic force microscopy , 1993 .

[3]  J. Marohn,et al.  MECHANICAL MODULATION OF SAMPLE MAGNETIZATION IN MAGNETIC RESONANCE FORCE MICROSCOPY , 1999 .

[4]  Detection of higher order modulation harmonics in magnetic resonance force microscopy , 2007 .

[5]  R. Wiesendanger,et al.  A scanning force microscope with atomic resolution in ultrahigh vacuum and at low temperatures , 1998 .

[6]  B. Chui,et al.  Single spin detection by magnetic resonance force microscopy , 2004, Nature.

[7]  Daniel Rugar,et al.  Paramagnetic and ferromagnetic resonance imaging with a tip-on-cantilever magnetic resonance force microscope , 1998 .

[8]  R. E. Thomson LOW-TEMPERATURE ATOMIC FORCE MICROSCOPE USING PIEZORESISTIVE CANTILEVERS , 1999 .

[9]  O. Beckman,et al.  A stripline resonator for ESR , 1974 .

[10]  P. Grutter,et al.  Magnetic imaging and dissipation force microscopy of vortices on superconducting Nb films , 2002 .

[11]  U. Hartmann,et al.  Fiber interferometer-based variable temperature scanning force microscope , 1997 .

[12]  U. Hartmann Magnetic force microscopy , 1990 .

[13]  J. Sidles,et al.  Noninductive detection of single‐proton magnetic resonance , 1991 .

[14]  C. V. Heer,et al.  Statistical mechanics, kinetic theory, and stochastic processes , 1972 .

[15]  D. Rugar,et al.  Nuclear magnetic resonance imaging with 90-nm resolution. , 2007, Nature Nanotechnology.

[16]  B. Gotsmann,et al.  Brownian Motion of Microscopic Solids under the Action of Fluctuating Electromagnetic Fields , 1999 .

[17]  Force-detected magnetic resonance in a field gradient of 250 000 Tesla per meter , 1998 .

[18]  D. Pelekhov,et al.  Atomic force microscope for operation in high magnetic fields at millikelvin temperatures , 1999 .

[19]  J. Chae,et al.  Versatile low-temperature atomic force microscope with in situ piezomotor controls, charge-coupled device vision, and tip-gated transport measurement capability , 2005 .

[20]  Detailed description of a compact cryogenic magnetic resonance force microscope , 2001 .

[21]  Y. Sugawara,et al.  Low-temperature noncontact atomic-force microscope with quick sample and cantilever exchange mechanism , 2001 .

[22]  J. Garbini,et al.  Anharmonic modulation for noise reduction in magnetic resonance force microscopy , 1995 .

[23]  Urs Dürig,et al.  DYNAMIC FORCE MICROSCOPY BY MEANS OF THE PHASE-CONTROLLED OSCILLATOR METHOD , 1997 .

[24]  T. Kenny,et al.  Attonewton force detection using ultrathin silicon cantilevers , 1997 .

[25]  Daniel Rugar,et al.  THREE-DIMENSIONAL IMAGING WITH A NUCLEAR MAGNETIC RESONANCE FORCE MICROSCOPE , 1996 .

[26]  N. Amer,et al.  Novel optical approach to atomic force microscopy , 1988 .

[27]  P. Grutter,et al.  Magnetic force microscopy studies of patterned magnetic structures , 2003 .

[28]  V. Naletov,et al.  Magnetic resonance studies of the fundamental spin-wave modes in individual submicron Cu/NiFe/Cu perpendicularly magnetized disks. , 2006, Physical review letters.

[29]  Probe--sample coupling in the magnetic resonance force microscope. , 2002, Journal of magnetic resonance.

[30]  T. Kenny,et al.  Electron spin relaxation near a micron-size ferromagnet. , 2001, Physical review letters.

[31]  P. S. Fodor,et al.  Variable-temperature scanning optical and force microscope , 2004, cond-mat/0403185.

[32]  H. Güntherodt,et al.  A low temperature ultrahigh vaccum scanning force microscope , 1999 .

[33]  J. Baldwin,et al.  Ferromagnetic resonance force microscopy on a thin permalloy film , 2007, 0704.2442.

[34]  Joseph L. Garbini,et al.  Nanometer-scale magnetic resonance imaging , 2004 .

[35]  Frank Pobell Matter and Methods at Low Temperatures , 2007 .

[36]  D. Smith,et al.  Low-temperature force microscope with all-fiber interferometer , 1992 .

[37]  D. Rugar,et al.  Frequency modulation detection using high‐Q cantilevers for enhanced force microscope sensitivity , 1991 .

[38]  Joseph L. Garbini,et al.  Thermal tuning of a fiber-optic interferometer for maximum sensitivity , 1999 .

[39]  R. Wiesendanger,et al.  A low-temperature ultrahigh vacuum scanning force microscope with a split-coil magnet , 2002 .

[40]  D. Rugar,et al.  Mechanical detection of magnetic resonance , 1992, Nature.

[41]  J. Baldwin,et al.  Temperature-dependent magnetic resonance force microscopy studies of a thin Permalloy film , 2007 .

[42]  P. Grutter,et al.  Cryogenic magnetic force microscope , 2000 .

[43]  D. Rugar,et al.  Nanoscale magnetic resonance imaging , 2009, Proceedings of the National Academy of Sciences.

[44]  K. Temst,et al.  Low temperature magnetic force microscopy with enhanced sensitivity based on piezoresistive detection , 2000 .

[45]  T. Kenny,et al.  Noncontact friction and force fluctuations between closely spaced bodies. , 2001, Physical review letters.

[46]  P. Wigen,et al.  Observation of ferromagnetic resonance in a microscopic sample using magnetic resonance force microscopy , 1996 .

[47]  M. Tortonese,et al.  Low temperature magnetic force microscope utilizing a piezoresistive cantilever , 1994 .

[48]  T. Ihn,et al.  A low-temperature dynamic mode scanning force microscope operating in high magnetic fields , 1999, cond-mat/9901023.

[49]  Tien-Ming Chuang,et al.  Compact variable-temperature scanning force microscope. , 2007, The Review of scientific instruments.

[50]  Z. Khim,et al.  Compact variable-temperature magnetic force microscope with optical access and lateral cantilever positioning , 2006 .

[51]  S. R. Garner,et al.  Batch fabrication and characterization of ultrasensitive cantilevers with submicron magnetic tips , 2004 .

[52]  D. Rugar,et al.  Improved fiber‐optic interferometer for atomic force microscopy , 1989 .

[53]  R. Movshovich,et al.  Local ferromagnetic resonance imaging with magnetic resonance force microscopy. , 2008, Physical review letters.

[54]  D. Rugar,et al.  Force Detection of Nuclear Magnetic Resonance , 1994, Science.

[55]  A. Suter The Magnetic Resonance Force Microscope , 2004 .