In vivo transcranial cavitation threshold detection during ultrasound-induced blood–brain barrier opening in mice

The in vivo cavitation response associated with blood-brain barrier (BBB) opening as induced by transcranial focused ultrasound (FUS) in conjunction with microbubbles was studied in order to better identify the underlying mechanism in its noninvasive application. A cylindrically focused hydrophone, confocal with the FUS transducer, was used as a passive cavitation detector (PCD) to identify the threshold of inertial cavitation (IC) in the presence of Definity® microbubbles (mean diameter range: 1.1-3.3 µm, Lantheus Medical Imaging, MA, USA). A vessel phantom was first used to determine the reliability of the PCD prior to in vivo use. A cerebral blood vessel was simulated by generating a cylindrical channel of 610 µm in diameter inside a polyacrylamide gel and by saturating its volume with microbubbles. The microbubbles were sonicated through an excised mouse skull. Second, the same PCD setup was employed for in vivo noninvasive (i.e. transdermal and transcranial) cavitation detection during BBB opening. After the intravenous administration of Definity® microbubbles, pulsed FUS was applied (frequency: 1.525 or 1.5 MHz, peak-rarefactional pressure: 0.15-0.60 MPa, duty cycle: 20%, PRF: 10 Hz, duration: 1 min with a 30 s interval) to the right hippocampus of twenty-six (n = 26) mice in vivo through intact scalp and skull. T1 and T2-weighted MR images were used to verify the BBB opening. A spectrogram was generated at each pressure in order to detect the IC onset and duration. The threshold of BBB opening was found to be at a 0.30 MPa peak-rarefactional pressure in vivo. Both the phantom and in vivo studies indicated that the IC pressure threshold had a peak-rarefactional amplitude of 0.45 MPa. This indicated that BBB opening may not require IC at or near the threshold. Histological analysis showed that BBB opening could be induced without any cellular damage at 0.30 and 0.45 MPa. In conclusion, the cavitation response could be detected without craniotomy in mice and IC may not be required for BBB opening at relatively low pressures.

[1]  P. Dayton,et al.  Threshold of fragmentation for ultrasonic contrast agents. , 2001, Journal of biomedical optics.

[2]  J. Fowlkes,et al.  An in vitro study of the correlation between bubble distribution, acoustic emission, and cell damage by contrast ultrasound , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  Paul A Dayton,et al.  Direct observations of ultrasound microbubble contrast agent interaction with the microvessel wall. , 2007, The Journal of the Acoustical Society of America.

[4]  James J. Choi,et al.  Noninvasive, transcranial and localized opening of the blood-brain barrier using focused ultrasound in mice. , 2007, Ultrasound in medicine & biology.

[5]  S A Small,et al.  Spatio-temporal analysis of molecular delivery through the blood–brain barrier using focused ultrasound , 2007, Physics in medicine and biology.

[6]  E. Konofagou,et al.  Permeability assessment of the focused ultrasound-induced blood–brain barrier opening using dynamic contrast-enhanced MRI , 2010, Physics in medicine and biology.

[7]  Yau-Yau Wai,et al.  Hemorrhage detection during focused-ultrasound induced blood-brain-barrier opening by using susceptibility-weighted magnetic resonance imaging. , 2008, Ultrasound in medicine & biology.

[8]  K. Hynynen,et al.  Resonance frequency of microbubbles in small blood vessels: a numerical study. , 2005 .

[9]  Eleanor Stride,et al.  The natural frequencies of microbubble oscillation in elastic vessels. , 2009, The Journal of the Acoustical Society of America.

[10]  Juan Tu,et al.  Inertial cavitation dose produced in ex vivo rabbit ear arteries with Optison by 1-MHz pulsed ultrasound. , 2006, Ultrasound in medicine & biology.

[11]  Ronald A. Roy,et al.  A precise technique for the measurement of acoustic cavitation thresholds and some preliminary results. , 1985, The Journal of the Acoustical Society of America.

[12]  W L Nyborg,et al.  Biological effects of ultrasound: development of safety guidelines. Part II: general review. , 2001, Ultrasound in medicine & biology.

[13]  Yao-Sheng Tung,et al.  Identifying the inertial cavitation threshold and skull effects in a vessel phantom using focused ultrasound and microbubbles. , 2010, Ultrasound in medicine & biology.

[14]  Hairong Zheng,et al.  Ultrasound-driven microbubble oscillation and translation within small phantom vessels. , 2007, Ultrasound in medicine & biology.

[15]  Yao-Sheng Tung,et al.  Microbubble-Size Dependence of Focused Ultrasound-Induced Blood–Brain Barrier Opening in Mice In Vivo , 2010, IEEE Transactions on Biomedical Engineering.

[16]  Natalia Vykhodtseva,et al.  MRI-guided targeted blood-brain barrier disruption with focused ultrasound: histological findings in rabbits. , 2005, Ultrasound in medicine & biology.

[17]  A. Brayman,et al.  Correlation between inertial cavitation dose and endothelial cell damage in vivo. , 2006, Ultrasound in medicine & biology.

[18]  Katherine W Ferrara,et al.  Acoustic response of compliable microvessels containing ultrasound contrast agents , 2006, Physics in medicine and biology.

[19]  Elisa E Konofagou,et al.  Noninvasive and Transient Blood-Brain Barrier Opening in the Hippocampus of Alzheimer's Double Transgenic Mice Using Focused Ultrasound , 2008, Ultrasonic imaging.

[20]  D. Kleinfeld,et al.  Severe Blood–Brain Barrier Disruption and Surrounding Tissue Injury , 2009, Stroke.

[21]  W. Pardridge,et al.  Biopharmaceutical drug targeting to the brain , 2010, Journal of drug targeting.

[22]  P. Dayton,et al.  High-frequency dynamics of ultrasound contrast agents , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[23]  K. Hynynen,et al.  Use of ultrasound pulses combined with Definity for targeted blood-brain barrier disruption: a feasibility study. , 2007, Ultrasound in Medicine and Biology.

[24]  K. Hynynen,et al.  Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits. , 2001, Radiology.

[25]  Katherine W. Ferrara,et al.  The natural frequency of nonlinear oscillation of ultrasound contrast agents in microvessels. , 2007, Ultrasound in medicine & biology.

[26]  Alexander R. Klotz,et al.  Temperature change near microbubbles within a capillary network during focused ultrasound , 2010, Physics in medicine and biology.

[27]  Mariano G. Uberti,et al.  Effects of transcranial ultrasound and intravenous microbubbles on blood brain barrier permeability in a large animal model. , 2008, Ultrasound in medicine & biology.

[28]  Nico de Jong,et al.  Increasing the Endothelial Layer Permeability Through Ultrasound-Activated Microbubbles , 2010, IEEE Transactions on Biomedical Engineering.

[29]  T Deffieux,et al.  Numerical study of a simple transcranial focused ultrasound system applied to blood-brain barrier opening , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[30]  K. Hynynen,et al.  Targeted disruption of the blood–brain barrier with focused ultrasound: association with cavitation activity , 2006, Physics in medicine and biology.

[31]  Ronald A. Roy,et al.  Temporal and spatial detection of HIFU-induced inertial and hot-vapor cavitation with a diagnostic ultrasound system. , 2009, Ultrasound in medicine & biology.

[32]  Yao-Sheng Tung,et al.  Molecules of various pharmacologically-relevant sizes can cross the ultrasound-induced blood-brain barrier opening in vivo. , 2010, Ultrasound in medicine & biology.

[33]  Yao-Sheng Tung,et al.  Multi-modality safety assessment of blood-brain barrier opening using focused ultrasound and definity microbubbles: a short-term study. , 2010, Ultrasound in medicine & biology.

[34]  L A Crum,et al.  Cavitation microjets as a contributory mechanism for renal calculi disintegration in ESWL. , 1988, The Journal of urology.

[35]  Morton W. Miller,et al.  A review of in vitro bioeffects of inertial ultrasonic cavitation from a mechanistic perspective. , 1996, Ultrasound in medicine & biology.