Building characteristics associated with moisture related problems in 8,918 Swedish dwellings

Moisture problems in buildings have in a number of studies been shown to increase the risk for respiratory symptoms. The study Dampness in Buildings and Health (DBH) was initiated with the aim to identify health relevant exposures related to dampness in buildings. A questionnaire study about home environment with a focus on dampness problems and health was conducted in one county of Sweden (8,918 homes, response rate 79%). Building characteristics that were associated with one or more of the dampness indicators were for single-family houses, older houses, flat-roofed houses built in the 1960s and 1970s, houses with a concrete slab on the ground that were built before 1983. Moreover, tenancy and earlier renovation due to mould or moisture problems was strongly associated with dampness. A perception of dry air was associated with window-pane condensation, e.g. humid indoor air.

[1]  Kiril Georgiev Naydenov,et al.  A comparison between occupants’ and inspectors’ reports on home dampness and their association with the health of children: The ALLHOME study , 2008 .

[2]  Yuexia Sun,et al.  Validity of building characteristics and dorm dampness obtained in a self-administrated questionnaire. , 2007, The Science of the total environment.

[3]  Jan Sundell,et al.  How valid are parents' questionnaire responses regarding building characteristics, mouldy odour, and signs of moisture problems in Swedish homes? , 2007, Scandinavian journal of public health.

[4]  Linda Hägerhed Engman,et al.  Indoor Environmental Factors and its Associations with Asthma and Allergy Among Swedish Pre-School Children , 2006 .

[5]  Kim Robert Lisø,et al.  Learning from experience – an analysis of process induced building defects in Norway , 2006 .

[6]  J Crane,et al.  Risk factors for mold in housing: a national survey. , 2005, Indoor air.

[7]  N. Åberg,et al.  'Dampness' at home and its association with airway, nose, and skin symptoms among 10,851 preschool children in Sweden: a cross-sectional study. , 2005, Indoor air.

[8]  J Sundell,et al.  Association between ventilation rates in 390 Swedish homes and allergic symptoms in children. , 2005, Indoor air.

[9]  J. Jaakkola,et al.  Home Dampness and Molds, Parental Atopy, and Asthma in Childhood: A Six-Year Population-Based Cohort Study , 2004, Environmental health perspectives.

[10]  S. Bonini,et al.  Dampness in buildings as a risk factor for health effects, EUROEXPO: a multidisciplinary review of the literature (1998-2000) on dampness and mite exposure in buildings and health effects. , 2004, Indoor air.

[11]  J Sundell,et al.  Dampness in buildings and health (DBH): Report from an ongoing epidemiological investigation on the association between indoor environmental factors and health effects among children in Sweden. , 2004, Indoor air.

[12]  M Svartengren,et al.  Indoor exposures and recurrent wheezing in infants: a study in the BAMSE cohort , 2004, Acta paediatrica.

[13]  M Svartengren,et al.  Building characteristics, indoor air quality and recurrent wheezing in very young children (BAMSE). , 2004, Indoor air.

[14]  L. Mckay,et al.  What features of the home and the area might help to explain observed relationships between housing tenure and health? Evidence from the west of Scotland. , 2003, Health & place.

[15]  D. Jarvis,et al.  Environmental and occupational disorders Housing characteristics, reported mold exposure, and asthma in the European Community Respiratory Health Survey , 2002 .

[16]  J. Siemiatycki,et al.  0289 ”david´s cheese bread” method: workload quantitative exposure thresholds detection using adjusted hazard multivariate parametric modelling, useful in cumulative-trauma disorders prevention and within their causal assessment , 2017, Occupational and Environmental Medicine.

[17]  G. Pershagen,et al.  Dampness in buildings and health. Nordic interdisciplinary review of the scientific evidence on associations between exposure to "dampness" in buildings and health effects (NORDDAMP). , 2001, Indoor air.

[18]  D Norbäck,et al.  Sick building syndrome in relation to building dampness in multi-family residential buildings in Stockholm , 2001, International archives of occupational and environmental health.

[19]  P Wargocki,et al.  Perceived air quality, sick building syndrome (SBS) symptoms and productivity in an office with two different pollution loads. , 1999, Indoor air.

[20]  Anne Hyvärinen,et al.  Prevalence of moisture problems in Finnish houses , 1998 .

[21]  J. Peat,et al.  Effects of damp and mould in the home on respiratory health: a review of the literature , 1998, Allergy.

[22]  J. Sundquist,et al.  Indicators of socio-economic position and their relation to mortality in Sweden. , 1997, Social science & medicine.

[23]  A Nevalainen,et al.  Home dampness, moulds and their influence on respiratory infections and symptoms in adults in Finland. , 1996, The European respiratory journal.

[24]  S. Stewart-Brown,et al.  Damp housing and adult health: results from a lifestyle study in Worcester, England. , 1994, Journal of epidemiology and community health.

[25]  John D. Spengler,et al.  Respiratory Symptoms and Housing Characteristics , 1994 .

[26]  Jan Sundell,et al.  Indoor Air Humidity And Sensation Of Dryness As Risk Indicators Of Sbs , 1993 .

[27]  S M Hunt,et al.  Damp housing, mould growth, and symptomatic health state. , 1989, BMJ.

[28]  D. Strachan,et al.  Relationship between respiratory morbidity in children and the home environment. , 1986, Family practice.

[29]  P. L. Jensen,et al.  Human response to 78-hour exposure to dry air. , 1974, Archives of environmental health.