Hydroxyapatite coating improves fixation of pedicle screws

We investigated the effects of hydroxyapatite (HA) coating on the purchase of pedicle screws. A total of 23 consecutive patients undergoing lumbar fusion was randomly assigned to one of three treatment groups. The first received uncoated stainless-steel screws, the second screws which were partly coated with HA, and the third screws which were fully coated. The insertion torque was recorded. After 11 to 16 months, 21 screws had been extracted. The extraction torque was recorded. Radiographs were taken to assess fusion and to detect loosening of the screws.At removal, the extraction torques exceeded the upper limit of the torque wrench (600 Ncm) for many HA-coated screws. The calculated mean extraction torque was 29 ± 36 Ncm for the uncoated group, 447 ± 114 Ncm for the partly-coated group and 574 ± 52 Ncm for the fully-coated group. There were significant differences between all three groups (p < 0.001). There were more radiolucent zones surrounding the uncoated screws than the HA-coated screws (p < 0.001...

[1]  D J Downey,et al.  Optimizing Bone Screw Pullout Force , 1990, Journal of orthopaedic trauma.

[2]  S. Toksvig-Larsen,et al.  Enhanced Fixation With Hydroxyapatite Coated Pins , 1998, Clinical orthopaedics and related research.

[3]  Sidhu Ks,et al.  Spinal instrumentation in the management of degenerative disorders of the lumbar spine. , 1997 .

[4]  J W Frymoyer,et al.  An internal fixator for posterior application to short segments of the thoracic, lumbar, or lumbosacral spine. Design and testing. , 1986, Clinical orthopaedics and related research.

[5]  Michi Ken-ichi,et al.  The Effect of Aging on the Healing of Hydroxylapatite Implants , 1993 .

[6]  T. Zdeblick A prospective, randomized study of lumbar fusion. Preliminary results. , 1993, Spine.

[7]  T. Albrektsson Hydroxyapatite-coated implants: a case against their use. , 1998, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[8]  I. Redlund‐Johnell,et al.  Complications After Transpedicular Stabilization of the Spine: A Survivorship Analysis of 163 Cases , 1994, Spine.

[9]  T C Hearn,et al.  Insertional Torque and Pull‐out Strengths of Conical and Cylindrical Pedicle Screws in Cadaveric Bone , 1996, Spine.

[10]  S. Toksvig-Larsen,et al.  A Comparison of Hydroxyapatite-Coated, Titanium-Coated, and Uncoated Tapered External-Fixation Pins. An in Vivo Study in Sheep* , 1998, The Journal of bone and joint surgery. American volume.

[11]  S. Cook,et al.  Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design. , 2000, Journal of spinal disorders.

[12]  B. Sandén,et al.  Improved Bone–Screw Interface With Hydroxyapatite Coating: An In Vivo Study of Loaded Pedicle Screws in Sheep , 2001, Spine.

[13]  K Kaneda,et al.  Does spinal instrumentation influence the healing process of posterolateral spinal fusion? An in vivo animal model. , 1999, Spine.

[14]  T. Albrektsson,et al.  Short- and long-term animal studies with a plasma-sprayed calcium phosphate-coated implant. , 1997, Clinical oral implants research.

[15]  Ann Wennerberg,et al.  A histomorghometric study of screw‐shaped and removal torque titanium implants with three different surface topographies , 1995 .

[16]  B. Sandén,et al.  Improved extraction torque of hydroxyapatite-coated pedicle screws , 2000, European Spine Journal.

[17]  S. Garfin,et al.  Screw Fixation in the Human Sacrum: An In Vitro Study of the Biomechanics of Fixation , 1992, Spine.

[18]  G. Missenard,et al.  Hydroxylapatite-coated Diapason screws: first clinical report. , 1995, Journal of spinal disorders.

[19]  D. Eckhoff,et al.  Effect of Age on Bone Formation Around Orthopaedic Implants , 1995, Clinical orthopaedics and related research.

[20]  S D Cook,et al.  In vivo mechanical and histological characteristics of HA-coated implants vary with coating vendor. , 1995, Journal of biomedical materials research.

[21]  C. Dickman,et al.  A Historical Cohort Study of Pedicle Screw Fixation in Thoracic, Lumbar, and Sacral Spinal Fusions. , 1994, Spine.

[22]  O. Böstman,et al.  Complications of transpedicular lumbosacral fixation for non-traumatic disorders. , 1997, The Journal of bone and joint surgery. British volume.

[23]  G. Magyar,et al.  Hydroxyapatite coating of threaded pins enhances fixation. , 1997, The Journal of bone and joint surgery. British volume.