Capacitive micromachined ultrasound transducers for intravascular ultrasound imaging

Intravascular ultrasound (IVUS) is a burgeoning imaging technology that provides vital information for the diagnosis of coronary arterial diseases. A significant constituent that enables the IVUS system to attain high-resolution images is the ultrasound transducer, which acts as both a transmitter that sends acoustic waves and a detector that receives the returning signals. Being the most mature form of ultrasound transducer available in the market, piezoelectric transducers have dominated the field of biomedical imaging. However, there are some drawbacks associated with using the traditional piezoelectric ultrasound transducers such as difficulties in the fabrication of high-density arrays, which would aid in the acceleration of the imaging speed and alleviate motion artifact. The advent of microelectromechanical system (MEMS) technology has brought about the development of micromachined ultrasound transducers that would help to address this issue. Apart from the advantage of being able to be fabricated into arrays with lesser complications, the image quality of IVUS can be further enhanced with the easy integration of micromachined ultrasound transducers with complementary metal-oxide-semiconductor (CMOS). This would aid in the mitigation of parasitic capacitance, thereby improving the signal-to-noise. Currently, there are two commonly investigated micromachined ultrasound transducers, piezoelectric micromachined ultrasound transducers (PMUTs) and capacitive micromachined ultrasound transducers (CMUTs). Currently, PMUTs face a significant challenge where the fabricated PMUTs do not function as per their design. Thus, CMUTs with different array configurations have been developed for IVUS. In this paper, the different ultrasound transducers, including conventional-piezoelectric transducers, PMUTs and CMUTs, are reviewed, and a summary of the recent progress of CMUTs for IVUS is presented.

[1]  O. Oralkan,et al.  Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  O. Oralkan,et al.  Fabrication of Flexible Transducer Arrays With Through-Wafer Electrical Interconnects Based on Trench Refilling With PDMS , 2008, Journal of Microelectromechanical Systems.

[3]  Sang-Gook Kim,et al.  Printing of uniform PZT thin films for MEMS applications , 2013 .

[4]  Zhenhao Li,et al.  Design and Fabrication of a High-Power Air-Coupled Capacitive Micromachined Ultrasonic Transducer Array With Concentric Annular Cells , 2017, IEEE Transactions on Electron Devices.

[5]  M. Leon,et al.  In vivo validation of intravascular ultrasound length measurements using a motorized transducer pullback system. , 1996, The American journal of cardiology.

[6]  P. Yock,et al.  Novel Pathophysiological Insights and Current Clinical Applications , 2001 .

[7]  J. Brian Fowlkes,et al.  A 32 x 32 capacitive micromachined ultrasonic transducer array manufactured in standard CMOS , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  John T. W. Yeow,et al.  CMUT front-end circuits designed in a high-voltage CMOS process and the phase measurement receiver circuit , 2012, 2012 IEEE International Ultrasonics Symposium.

[9]  Liming Nie,et al.  Photoacoustic tomography of monkey brain using virtual point ultrasonic transducers. , 2011, Journal of biomedical optics.

[10]  F. Levent Degertekin,et al.  Microscale systems based on ultrasonic MEMS — CMOS integration , 2017, 2017 19th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS).

[11]  Liming Nie,et al.  In vivo photoacoustic imaging dynamically monitors the structural and functional changes of ischemic stroke at a very early stage , 2020, Theranostics.

[12]  Maysam Ghovanloo,et al.  Single-Chip Reduced-Wire CMUT-on-CMOS System for Intracardiac Echocardiography , 2018, 2018 IEEE International Ultrasonics Symposium (IUS).

[13]  J. Ryu,et al.  Review of piezoelectric micromachined ultrasonic transducers and their applications , 2017 .

[14]  Toby Xu,et al.  Real-time imaging system using a 12-MHz forward-looking catheter with single chip CMUT-on-CMOS array , 2015, 2015 IEEE International Ultrasonics Symposium (IUS).

[15]  R. Goldberg,et al.  Hyaluronic acid gel distribution pattern in periocular area with high-resolution ultrasound imaging. , 2014, Aesthetic surgery journal.

[16]  Qifa Zhou,et al.  Multi-frequency intravascular ultrasound (IVUS) imaging , 2015, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[17]  Yoichi Haga,et al.  Fabrication and Packaging of CMUT Using Low Temperature Co-Fired Ceramic , 2018, Micromachines.

[18]  Qifa Zhou,et al.  Micromachined PIN-PMN-PT crystal composite transducer for high-frequency intravascular ultrasound (IVUS) imaging , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[19]  V. Nagaraja,et al.  When to use intravascular ultrasound or optical coherence tomography during percutaneous coronary intervention? , 2020, Cardiovascular diagnosis and therapy.

[20]  R. Rakhit,et al.  Choice of Intracoronary Imaging: When to use Intravascular Ultrasound or Optical Coherence Tomography. , 2016, Interventional cardiology.

[21]  Lawrence L P Wong,et al.  An FPGA-based ultrasound imaging system using capacitive micromachined ultrasonic transducers , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  O. Oralkan,et al.  3-D ultrasound imaging using a forward-looking CMUT ring array for intravascular/intracardiac applications , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[23]  Zhenhao Li,et al.  A row-column addressed micromachined ultrasonic transducer array for surface scanning applications. , 2014, Ultrasonics.

[24]  Alexander F. Kolen,et al.  Quantitative imaging performance of frequency‐tunable capacitive micromachined ultrasonic transducer array designed for intracardiac application: Phantom study , 2018, Ultrasonics.

[25]  Yoshiaki Kawase,et al.  Comparison of nonuniform rotational distortion between mechanical IVUS and OCT using a phantom model. , 2007, Ultrasound in medicine & biology.

[26]  Butrus T. Khuri-Yakub,et al.  Capacitive Micromachined Ultrasonic Transducers: Theory and Technology , 2003 .

[27]  Margaret King,et al.  State of the art and perspectives , 2004, Machine Translation.

[28]  Cheng-Min Chang,et al.  Development of a Novel Transparent Flexible Capacitive Micromachined Ultrasonic Transducer , 2017, Sensors.

[29]  Yongqiang Qiu,et al.  Piezoelectric Micromachined Ultrasound Transducer (PMUT) Arrays for Integrated Sensing, Actuation and Imaging , 2015, Sensors.

[30]  M. Kessentini,et al.  A Systematic Literature Review , 2016 .

[31]  Z. Ali,et al.  Imaging Comparisons of Coregistered Native and Stented Coronary Segments by High-Definition 60-MHz Intravascular Ultrasound and Optical Coherence Tomography. , 2016, JACC. Cardiovascular interventions.

[32]  Yu Liu,et al.  In Vivo Photoacoustic Imaging of Brain Injury and Rehabilitation by High‐Efficient Near‐Infrared Dye Labeled Mesenchymal Stem Cells with Enhanced Brain Barrier Permeability , 2017, Advanced science.

[33]  Yipeng Lu,et al.  High frequency piezoelectric micromachined ultrasonic transducer array for intravascular ultrasound imaging , 2014, 2014 IEEE 27th International Conference on Micro Electro Mechanical Systems (MEMS).

[34]  A. Uranga,et al.  Monolithical AlN PMUT on Pre-Processed CMOS Substrate , 2018, 2018 IEEE International Frequency Control Symposium (IFCS).

[35]  O. Oralkan,et al.  Forward-viewing CMUT arrays for medical imaging , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[36]  Naseer Sabri,et al.  Capacitive Micromachined Ultrasonic Transducers: Technology and Application , 2012 .

[37]  Brian C Wilson,et al.  Design, Fabrication, and Characteristics of a MEMS Micromirror With Sidewall Electrodes , 2010, Journal of Microelectromechanical Systems.

[38]  Zhou Zheng,et al.  Photoacoustic Imaging with Capacitive Micromachined Ultrasound Transducers: Principles and Developments , 2019, Sensors.

[39]  T. Ma,et al.  (100)-Textured KNN-based thick film with enhanced piezoelectric property for intravascular ultrasound imaging. , 2015, Applied physics letters.

[40]  David M. Mills,et al.  4-D ICE: A 2-D Array Transducer With Integrated ASIC in a 10-Fr Catheter for Real-Time 3-D Intracardiac Echocardiography , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[41]  John T.W. Yeow,et al.  A robust control approach for MEMS capacitive micromachined ultrasonic transducer , 2019 .

[42]  Yanfang Huang,et al.  In Vivo Quantitative Photoacoustic Diagnosis of Gastric and Intestinal Dysfunctions with a Broad pH-Responsive Sensor. , 2019, ACS nano.

[43]  Tat-Jin Teo,et al.  Intravascular ultrasound (IVUS) — Technologies and applications , 2010, 2010 IEEE International Ultrasonics Symposium.

[45]  Dooyoung Hah,et al.  All-polymer ultrasonic transducer design for an intravascular ultrasonography application , 2019, Turkish J. Electr. Eng. Comput. Sci..

[46]  Rudra Pratap,et al.  Ring PMUT array based miniaturized photoacoustic endoscopy device , 2019, BiOS.

[47]  D.N. Stephens,et al.  Forward-looking intracardiac ultrasound imaging using a 1-D CMUT array integrated with custom front-end electronics , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[48]  Lihong V. Wang,et al.  Photoacoustic endoscopy. , 2009, Optics letters.

[49]  Chang Han Je,et al.  Design of capacitive micromachined ultrasonic transducers (CMUTs) on a flexible substrate for intravascular ultrasonography (IVUS) applications , 2017, 2017 Symposium on Design, Test, Integration and Packaging of MEMS/MOEMS (DTIP).

[50]  E. Scavetta,et al.  Nanogenerators based on ZnO or TiO2 oxides. , 2010, Journal of nanoscience and nanotechnology.

[51]  Maysam Ghovanloo,et al.  Towards a Reduced-Wire Interface for CMUT-Based Intravascular Ultrasound Imaging Systems , 2017, IEEE Transactions on Biomedical Circuits and Systems.

[52]  Junhong Li,et al.  Design and Fabrication of Piezoelectric Micromachined Ultrasound Transducer (pMUT) with Partially-Etched ZnO Film , 2017, Sensors.

[53]  J. Yeow,et al.  Fabricating capacitive micromachined ultrasonic transducers with a novel silicon-nitride-Based wafer bonding process , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[54]  S. Drăgan,et al.  Heart Involvement in Inflammatory Rheumatic Diseases: A Systematic Literature Review , 2019, Medicina.

[55]  J. Fujimoto Optical coherence tomography for ultrahigh resolution in vivo imaging , 2003, Nature Biotechnology.

[56]  Adrien E Desjardins,et al.  All-optical forward-viewing photoacoustic probe for high-resolution 3D endoscopy , 2018, Light: Science & Applications.

[57]  Mario Kupnik,et al.  Fabrication of CMUT Cells with Gold Center Mass for Higher Output Pressure , 2011 .

[58]  Maysam Ghovanloo,et al.  Design, modeling and characterization of a 35MHz 1-D CMUT phased array , 2013, 2013 IEEE International Ultrasonics Symposium (IUS).

[59]  David M. Fried,et al.  THE DESIGN, FABRICATION AND CHARACTERIZATION OF , 2004 .

[60]  Mario Kupnik,et al.  CMUT fabrication based on a thick buried oxide layer , 2010, 2010 IEEE International Ultrasonics Symposium.

[61]  Patrick W Serruys,et al.  Imaging of coronary atherosclerosis: intravascular ultrasound. , 2010, European heart journal.

[62]  E. Topol,et al.  Our preoccupation with coronary luminology. The dissociation between clinical and angiographic findings in ischemic heart disease. , 1995, Circulation.

[63]  B. Khuri-Yakub,et al.  Capacitive micromachined ultrasonic transducers: next-generation arrays for acoustic imaging? , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[64]  John T.W. Yeow,et al.  Tracking of square reference signals using internal model-based LQG robust controller for positioning of a micro-electro-mechanical systems micromirror , 2018 .

[65]  Ping Liu,et al.  Development of a Novel CMUT-Based Concentric Dual-Element Ultrasonic Transducer: Design, Fabrication, and Characterization , 2018, Journal of Microelectromechanical Systems.

[66]  Ali Boukabache,et al.  Low-stress fabrication of 3D polymer free standing structures using lamination of photosensitive films , 2008 .

[67]  Toby Xu,et al.  Single-chip CMUT-on-CMOS front-end system for real-time volumetric IVUS and ICE imaging , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[68]  Srinivas Tadigadapa,et al.  Piezoelectric MEMS sensors: state-of-the-art and perspectives , 2009 .

[69]  A circular array transducer for photoacoustic imaging by using piezoelectric single crystal lead magnesium niobate–lead zirconate titanate , 2015 .

[70]  N. Shammas,et al.  The role of precise imaging with intravascular ultrasound in coronary and peripheral interventions , 2019, Vascular health and risk management.

[71]  P. Yock,et al.  Two-dimensional intravascular ultrasound: technical development and initial clinical experience. , 1989, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[72]  Qifa Zhou,et al.  PMN-PT single-crystal high-frequency kerfless phased array , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[73]  L. Hongwei,et al.  Design and fabrication of high frequency BNT film based linear array transducer , 2015 .

[74]  O. V. von Ramm,et al.  In vivo real-time 3-D intracardiac echo using PMUT arrays , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[75]  F. Degertekin,et al.  Investigation of dual mode side and forward looking IVUS using a dual ring CMUT-on-CMOS array , 2012, 2012 IEEE International Ultrasonics Symposium.

[76]  P. Yock,et al.  Intravascular ultrasound: novel pathophysiological insights and current clinical applications. , 2001, Circulation.

[77]  Eduardo T. Costa,et al.  Influence of backing and matching layers in ultrasound transducer performance , 2003, SPIE Medical Imaging.

[78]  Morten Fischer Rasmussen,et al.  Advances in Capacitive Micromachined Ultrasonic Transducers , 2019, Micromachines.

[79]  M. Karaman,et al.  5G-5 Dual-Annular-Ring CMUT Array for ForwardLooking IVUS Imaging , 2006, 2006 IEEE Ultrasonics Symposium.

[80]  Jin Ho Sung,et al.  Development of High-Frequency (>60 MHz) Intravascular Ultrasound (IVUS) Transducer by Using Asymmetric Electrodes for Improved Beam Profile , 2018, Sensors.

[81]  K. Srinivasa Rao,et al.  Fringing Capacitive Effect of Silicon Carbide Based Nano-Electro-Mechanical-System Micromachined Ultrasonic Transducers: Analytical Modeling and FEM Simulation , 2019, Transactions on Electrical and Electronic Materials.

[82]  Amin Nikoozadeh,et al.  CMUT with substrate-embedded springs for non-flexural plate movement , 2010, 2010 IEEE International Ultrasonics Symposium.

[83]  E. Olcott,et al.  Capsule ultrasound device , 2015, 2015 IEEE International Ultrasonics Symposium (IUS).

[84]  John T.W. Yeow,et al.  Closed-loop control of a 2-D mems micromirror with sidewall electrodes for a laser scanning microscope system , 2016 .

[85]  Hoi-Jun Yoo,et al.  11.1 A 5.37mW/Channel Pitch-Matched Ultrasound ASIC with Dynamic-Bit-Shared SAR ADC and 13.2V Charge-Recycling TX in Standard CMOS for Intracardiac Echocardiography , 2019, 2019 IEEE International Solid- State Circuits Conference - (ISSCC).

[86]  Toby Xu,et al.  Monolithic CMUT-on-CMOS integration for intravascular ultrasound applications , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[87]  Amin Nikoozadeh,et al.  3D volumetric ultrasound imaging with a 32×32 CMUT array integrated with front-end ICs using flip-chip bonding technology , 2013, 2013 IEEE International Solid-State Circuits Conference Digest of Technical Papers.

[88]  Xuecheng Jin,et al.  An efficient electrical addressing method using through-wafer vias for two-dimensional ultrasonic arrays , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[89]  S. Gambhir,et al.  1E-3 Tomographic Photoacoustic Imaging Using Capacitive Micromachined Ultrasonic Transducer (CMUT) Technology , 2006, 2006 IEEE Ultrasonics Symposium.

[90]  B. Boser,et al.  ALUMINUM NITRIDE PIEZOELECTRIC MICROMACHINED ULTRASOUND TRANSDUCER ARRAYS , 2012 .

[91]  J. Roelandt,et al.  Intravascular ultrasound , 1989, Springer Netherlands.

[92]  Chengkuo Lee,et al.  Zero-Bending Piezoelectric Micromachined Ultrasonic Transducer (pMUT) With Enhanced Transmitting Performance , 2015, Journal of Microelectromechanical Systems.

[93]  T. G. van Leeuwen,et al.  Quantitative comparison of the OCT imaging depth at 1300 nm and 1600 nm , 2010, Biomedical optics express.

[94]  Nico de Jong,et al.  A 2-D Ultrasound Transducer With Front-End ASIC and Low Cable Count for 3-D Forward-Looking Intravascular Imaging: Performance and Characterization , 2018, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[95]  A. Safari,et al.  Fabrication and evaluation of a single-element Bi0.5Na0.5TiO3-based ultrasonic transducer , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.