Smart passive control of buildings with higher redundancy and robustness using base-isolation and inter-connection

It is known that a base-isolated building exhibits a large response to a long-duration, long-period wave and an inter-connected system without base-isolation shows a large response to a pulse-type wave. To compensate for each deficiency, a new hybrid passive control system is investigated in which a base-isolated building is connected to another building (free wall) with oil dampers. It is demonstrated that the present hybrid passive control system is effective both for pulse-type ground motions and long-duration and long-period ground motions and has high redundancy and robustness for a broad range of disturbances.

[1]  Y. Ben-Haim Information-gap decision theory : decisions under severe uncertainty , 2001 .

[2]  James M. Kelly,et al.  The role of damping in seismic isolation , 1999 .

[3]  Izuru Takewaki,et al.  Bound of aspect ratio of base-isolated buildings considering nonlinear tensile behavior of rubber bearing , 2008 .

[4]  Hyung-Jo Jung,et al.  A feasibility study on smart base isolation systems using magneto-rheological elastomers , 2009 .

[5]  Hong-Nan Li,et al.  Limitations of height-to-width ratio for base-isolated buildings under earthquake , 2006 .

[6]  Kohei Fujita,et al.  Uncertainties in long-period ground motion and its impact on building structural design: Case study of the 2011 Tohoku (Japan) earthquake , 2013 .

[7]  Kohei Fujita,et al.  The 2011 off the Pacific coast of Tohoku earthquake and response of high-rise buildings under long-period ground motions , 2011 .

[8]  Turan Karabork,et al.  Performance of multi-storey structures with high damping rubber bearing base isolation systems , 2011 .

[9]  A. Agrawal,et al.  Analytical Model of Ground Motion Pulses for the Design and Assessment of Seismic Protective Systems , 2008 .

[10]  Izuru Takewaki,et al.  Scaling of design earthquake ground motions for tall buildings based on drift and input energy demands , 2011 .

[11]  A. Agrawal,et al.  Performance of passive energy dissipation systems during near-field ground motion type pulses , 2007 .

[12]  Kohei Fujita,et al.  Earthquake input energy to tall and base‐isolated buildings in time and frequency dual domains , 2009 .

[13]  Kohei Fujita,et al.  Improving the Earthquake Resilience of Buildings: The worst case approach , 2012 .

[14]  T. K. Datta,et al.  Nonlinear Response of Torsionally Coupled Base Isolated Structure , 1994 .

[15]  R. S. Jangid,et al.  Dynamic response of adjacent structures connected by friction damper , 2011 .

[16]  Luigi Petti,et al.  SMALL SCALE EXPERIMENTAL TESTING TO VERIFY THE EFFECTIVENESS OF THE BASE ISOLATION AND TUNED MASS DAMPERS COMBINED CONTROL STRATEGY , 2010 .

[17]  Marvin W. Halling,et al.  Near-Source Ground Motion and its Effects on Flexible Buildings , 1995 .

[18]  D. Wald,et al.  Response of High-Rise and Base-Isolated Buildings to a Hypothetical Mw 7.0 Blind Thrust Earthquake , 1995, Science.

[19]  Izuru Takewaki,et al.  Uncertain-parameter sensitivity of earthquake input energy to base-isolated structure , 2005 .

[20]  Izuru Takewaki,et al.  Resonant behaviour of base‐isolated high‐rise buildings under long‐period ground motions , 2006 .

[21]  Izuru Takewaki,et al.  Robustness of base‐isolated high‐rise buildings under code‐specified ground motions , 2008 .

[22]  Makoto Ohsaki,et al.  Optimization And Anti-Optimization Of Structures Under Uncertainty , 2010 .

[23]  R. S. Jangid,et al.  Effects of Isolation Damping on Stochastic Response of Structures with Nonlinear Base Isolators , 1998 .

[24]  Izuru Takewaki,et al.  Earthquake Input Energy to Two Buildings Connected by Viscous Dampers , 2007 .

[25]  Katsuhisa Nishimura,et al.  RESPONSE CONTROL EFFECT OF HI-RISED REINFORCED CONCRETE BUILDING USING COUPLED VIBRATION CONTROL STRUCTURE , 2008 .

[26]  Izuru Takewaki,et al.  Critical excitation methods in earthquake engineering , 2006 .

[27]  Farzad Naeim,et al.  Design of seismic isolated structures , 1999 .

[28]  C. A. Morales,et al.  Transmissibility concept to control base motion in isolated structures , 2003 .

[29]  R. S. Jangid,et al.  Base isolation for near‐fault motions , 2001 .