Real-time PCR-based microfluidic array chip for simultaneous detection of multiple waterborne pathogens

We report disposable microfluidic devices harboring an array of unsealed reactors, which are pre-loaded with different primer pairs for simultaneous (parallel) real-time PCR-based detection of multiple waterborne pathogens. The PCR mixture loading among an array of reactors and subsequent isolation of the reactors was solely realized by a single step capillary-based flow scheme, which eliminates the use of pumps, valves and liquid handling instruments. We incorporated a localized thermal cycling scheme to minimize evaporative loss of PCR mixture in unsealed microreactors, which greatly reduces the complexity of the microfabrication and fluidic operation process, in cases, where valving or sealing of the reactors for PCR thermal cycling is required. Experiments were performed to determine the optimal microreactor design parameters, so as to perform bubble-free PCR with minimal evaporative loss in unsealed reactors. The potential of the microfluidic device was successfully demonstrated by specifically detecting genomic DNA of waterborne pathogens from a pool of genomic DNA template.

[1]  A. Mirzabekov,et al.  PCR amplification on a microarray of gel-immobilized oligonucleotides: detection of bacterial toxin- and drug-resistant genes and their mutations. , 2000, BioTechniques.

[2]  Erdogan Gulari,et al.  Development and Experimental Validation of a Predictive Threshold Cycle Equation for Quantification of Virulence and Marker Genes by High-Throughput Nanoliter-Volume PCR on the OpenArray Platform , 2008, Applied and Environmental Microbiology.

[3]  Stephen R Quake,et al.  Solving the "world-to-chip" interface problem with a microfluidic matrix. , 2003, Analytical chemistry.

[4]  Z. Hugh Fan,et al.  Integrating polymerase chain reaction, valving, and electrophoresis in a plastic device for bacterial detection. , 2003, Analytical chemistry.

[5]  M. W. Mueller,et al.  Microarray-Based Identification of Bacteria in Clinical Samples by Solid-Phase PCR Amplification of 23S Ribosomal DNA Sequences , 2004, Journal of Clinical Microbiology.

[6]  Sergey E. Ilyin,et al.  Nanoliter high throughput quantitative PCR , 2006, Nucleic acids research.

[7]  Dae-Young Lee,et al.  Development and application of an oligonucleotide microarray and real-time quantitative PCR for detection of wastewater bacterial pathogens. , 2008, The Science of the total environment.

[8]  Y. Murakami,et al.  Development of a microchamber array for picoliter PCR. , 2001, Analytical chemistry.

[9]  Carole L Yauk,et al.  Comprehensive comparison of six microarray technologies. , 2004, Nucleic acids research.

[10]  F. Dobbs,et al.  Multiplex PCR allows simultaneous detection of pathogens in ships' ballast water. , 2004, Marine pollution bulletin.

[11]  P. Wilding,et al.  Microchip module for blood sample preparation and nucleic acid amplification reactions. , 2001, Genome research.

[12]  Microfabricated valveless devices for thermal bioreactions based on diffusion-limited evaporation. , 2008, Lab on a chip.

[13]  R. Mathies,et al.  Monolithic integrated microfluidic DNA amplification and capillary electrophoresis analysis system , 2000 .

[14]  R. Kong,et al.  Rapid detection of six types of bacterial pathogens in marine waters by multiplex PCR. , 2002, Water research.

[15]  Hai-Qing Gong,et al.  Micro air bubble formation and its control during polymerase chain reaction (PCR) in polydimethylsiloxane (PDMS) microreactors , 2007, Journal of Micromechanics and Microengineering.

[16]  Jian-Wen He,et al.  Quantification of Enterococci and Human Adenoviruses in Environmental Samples by Real-Time PCR , 2005, Applied and Environmental Microbiology.

[17]  J. Trevors,et al.  Application of real-time quantitative PCR for the detection of selected bacterial pathogens during municipal wastewater treatment. , 2007, The Science of the total environment.

[18]  P. H. Yap,et al.  Microfluidic handling of PCR solution and DNA amplification on a reaction chamber array biochip , 2006, Biomedical microdevices.

[19]  J. Paul,et al.  Quantification of Human Polyomaviruses JC Virus and BK Virus by TaqMan Quantitative PCR and Comparison to Other Water Quality Indicators in Water and Fecal Samples , 2009, Applied and Environmental Microbiology.

[20]  Kagan Kerman,et al.  Microchamber array based DNA quantification and specific sequence detection from a single copy via PCR in nanoliter volumes. , 2005, Biosensors & bioelectronics.

[21]  R C Anderson,et al.  A miniature integrated device for automated multistep genetic assays. , 2000, Nucleic acids research.

[22]  Dae-Young Lee,et al.  Detection of bacterial pathogens in municipal wastewater using an oligonucleotide microarray and real-time quantitative PCR. , 2006, Journal of microbiological methods.