Prevalence and Risk Factors Associated With Pelvic Rod/Screw Radiographic Lucency Following Scoliosis Surgery in Spastic Cerebral Palsy: A Longitudinal Study

Background: Radiographic lucency around a smooth pelvic rod (Galveston/unit rod technique) or sacroiliac/iliac screw following spinal fusion in children with nonambulatory spastic cerebral palsy (CP) has been described as a “windshield wiper” phenomenon. We evaluated demographics, radiographs, and complications in 101 cases from a single center to determine prevalence, risk factors, and complications associated with persistent radiographic lucency from 1 to 5 years following spinal fusion. Methods: Inclusion criteria were diagnosis of nonambulatory spastic quadriplegic CP [Gross Motor Function Classification System (GMFCS) IV-V], under 18 years of age, scoliosis treated by posterior fusion from upper thoracic to sacrum with pelvic fixation (Galveston rod, iliac screw, or sacroiliac screw), adequate radiographs (preoperative, immediate postoperative, first-year, and second-year), and minimum 5-year follow-up. We evaluated demographics, radiographic parameters, comorbidities, scoliosis curve type, type of pelvic screw/rod, use of off-set connector, screw width, associated with posterior column osteotomy and/or additional anterior spinal release concurrent with posterior spine fusion, and infection over the follow-up period. Specific attention was given to the area and shape of the radiographic lucency. The logistic regression analysis was performed for continuous and categorical variables to define risk factors (P=0.05). Results: In 101 patients, data were collected at mean intervals of 1-year, 2-year, and >5-year follow-up and were 12.9±1.5, 25.8±2.5, and 81.5±23.0 months, respectively. Prevalence of pelvic rod/screw radiographic lucency was unchanged at 33%, 35%, and 24% at 1-year, 2-year, and >5-year follow-up, respectively, and radiographic parameters did not change (P>0.05). Furthermore, no risk factors or complications were associated with radiographic lucency around pelvic rods/screws (P>0.05). Conclusion: In patients with spastic nonambulatory CP who had scoliosis treated with posterior spinal fusion from upper thorax to pelvis, the prevalence of pelvic rod/screw lucency is high. Persistent lucency >2 mm around pelvic implants is not clinically significant, does not warrant advanced imaging, or indicate a complication if stable over time and wider distally than proximally. Level of Evidence: Level III.

[1]  Zhongqiang Chen,et al.  Risk factors for screw loosening in patients with adult degenerative scoliosis: the importance of paraspinal muscle degeneration , 2021, Journal of Orthopaedic Surgery and Research.

[2]  A. Samdani,et al.  DEFORMITY C Three Methods of Pelvic Fixation for Scoliosis in Children With Cerebral Palsy , 2018 .

[3]  A. Leithner,et al.  Pedicle screw loosening is correlated to chronic subclinical deep implant infection: a retrospective database analysis , 2018, European Spine Journal.

[4]  G. Hägglund,et al.  Incidence of scoliosis in cerebral palsy , 2018, Acta orthopaedica.

[5]  Suken A. Shah,et al.  Correction of Pelvic Obliquity After Spinopelvic Fixation in Children With Cerebral Palsy: A Comparison Study With Minimum Two-Year Follow-up. , 2016, Spine deformity.

[6]  Amit Jain,et al.  Sacral-Alar-Iliac Fixation in Pediatric Deformity: Radiographic Outcomes and Complications , 2016, Spine deformity.

[7]  R. Lieber,et al.  Cerebral palsy , 2016, Nature Reviews Disease Primers.

[8]  W. Novicoff,et al.  The “Shadow Sign”: A Radiographic Differentiation of Stainless Steel Versus Titanium Spinal Instrumentation in Spine Surgery , 2011, Journal of pediatric orthopedics.

[9]  Jin Young Kim,et al.  Pelvic Obliquity in Neuromuscular Scoliosis: Radiologic Comparative Results of Single-Stage Posterior Versus Two-Stage Anterior and Posterior Approach , 2011, Spine.

[10]  S. Koop,et al.  Scoliosis in cerebral palsy , 2009, Developmental medicine and child neurology.

[11]  R. Buschbacher,et al.  Sacroiliac joint pain: anatomy, biomechanics, diagnosis, and treatment. , 2006, American journal of physical medicine & rehabilitation.

[12]  L. Lenke,et al.  Comparison of Pelvic Fixation Techniques in Neuromuscular Spinal Deformity Correction: Galveston Rod Versus Iliac and Lumbosacral Screws , 2006, Spine.

[13]  R. Betz,et al.  Scoliosis in the child with cerebral palsy. , 2006, The Journal of the American Academy of Orthopaedic Surgeons.

[14]  F. Chotel,et al.  [Pelvic obliquity and scoliosis in non-ambulatory patients with cerebral palsy: a descriptive study of 234 patients over 15 years of age]. , 2002, Revue de chirurgie orthopedique et reparatrice de l'appareil moteur.

[15]  J. W. Hardacker,et al.  The Safety and Efficacy of Isola-Galveston Instrumentation and Arthrodesis in the Treatment of Neuromuscular Spinal Deformities*† , 2000, The Journal of bone and joint surgery. American volume.

[16]  C. Wimmer,et al.  Aseptic loosening after CD instrumentation in the treatment of scoliosis: a report about eight cases. , 1998, Journal of spinal disorders.

[17]  K. Takaoka,et al.  Natural history of scoliosis in spastic cerebral palsy , 1998, The Lancet.