High-Performance Fluorescence Molecular Tomography through Shape-Based Reconstruction Using Spherical Harmonics Parameterization

Fluorescence molecular tomography in the near-infrared region is becoming a powerful modality for mapping the three-dimensional quantitative distributions of fluorochromes in live small animals. However, wider application of fluorescence molecular tomography still requires more accurate and stable reconstruction tools. We propose a shape-based reconstruction method that uses spherical harmonics parameterization, where fluorophores are assumed to be distributed as piecewise constants inside disjointed subdomains and the remaining background. The inverse problem is then formulated as a constrained nonlinear least-squares problem with respect to shape parameters, which decreases ill-posedness because of the significantly reduced number of unknowns. Since different shape parameters contribute differently to the boundary measurements, a two-step and modified block coordinate descent optimization algorithm is introduced to stabilize the reconstruction. We first evaluated our method using numerical simulations under various conditions for the noise level and fluorescent background; it showed significant superiority over conventional voxel-based methods in terms of the spatial resolution, reconstruction accuracy with regard to the morphology and intensity, and robustness against the initial estimated distribution. In our phantom experiment, our method again showed better spatial resolution and more accurate intensity reconstruction. Finally, the results of an in vivo experiment demonstrated its applicability to the imaging of mice.

[1]  Jie Tian,et al.  A fast reconstruction algorithm for fluorescence molecular tomography with sparsity regularization. , 2010, Optics express.

[2]  R. Weissleder,et al.  Fluorescence molecular tomography resolves protease activity in vivo , 2002, Nature Medicine.

[3]  Michael Hintermüller,et al.  Topological sensitivity analysis in fluorescence optical tomography , 2013 .

[4]  J. Bai,et al.  In-vivo fluorescence molecular tomography based on optimal small animal surface reconstruction , 2010 .

[5]  Jie Tian,et al.  Spectrally resolved three-dimensional bioluminescence tomography with a level-set strategy. , 2010, Journal of the Optical Society of America. A, Optics, image science, and vision.

[6]  Nanguang Chen,et al.  Reconstruction for free-space fluorescence tomography using a novel hybrid adaptive finite element algorithm. , 2007, Optics express.

[7]  Amir Beck,et al.  On the Convergence of Block Coordinate Descent Type Methods , 2013, SIAM J. Optim..

[8]  Ali Adibi,et al.  Total variation regularization for 3D reconstruction in fluorescence tomography: experimental phantom studies. , 2012, Applied optics.

[9]  Eric L. Miller,et al.  Data Specific Spatially Varying Regularization for Multimodal Fluorescence Molecular Tomography , 2010, IEEE Transactions on Medical Imaging.

[10]  Dana H. Brooks,et al.  Electrical Impedance Tomography for Piecewise Constant Domains Using Boundary Element Shape-Based Inverse Solutions , 2007, IEEE Transactions on Medical Imaging.

[11]  Xin Liu,et al.  Full-Angle Fluorescence Diffuse Optical Tomography With Spatially Coded Parallel Excitation , 2010, IEEE Transactions on Information Technology in Biomedicine.

[12]  R. Weissleder,et al.  Tomographic fluorescence mapping of tumor targets. , 2005, Cancer research.

[13]  J. Ripoll,et al.  Visualization of antitumor treatment by means of fluorescence molecular tomography with an annexin V-Cy5.5 conjugate. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[14]  Jianwen Luo,et al.  Reconstruction of Fluorescence Molecular Tomography Using a Neighborhood Regularization , 2012, IEEE Transactions on Biomedical Engineering.

[15]  A. Adibi,et al.  Optimal sparse solution for fluorescent diffuse optical tomography: theory and phantom experimental results. , 2007, Applied optics.

[16]  Xin Liu,et al.  A Combined Fluorescence and Microcomputed Tomography System for Small Animal Imaging , 2010, IEEE Transactions on Biomedical Engineering.

[17]  Jorge Ripoll,et al.  Use of Split Bregman denoising for iterative reconstruction in fluorescence diffuse optical tomography , 2013, Journal of biomedical optics.

[18]  Athanasios Zacharopoulos,et al.  Three-dimensional shape-based reconstructions in medical imaging , 2005 .

[19]  C. Clason,et al.  Total variation regularization for nonlinear fluorescence tomography with an augmented Lagrangian splitting approach. , 2010, Applied optics.

[20]  Vasilis Ntziachristos,et al.  A submillimeter resolution fluorescence molecular imaging system for small animal imaging. , 2003, Medical physics.

[21]  Anne Koenig,et al.  In vivo mice lung tumor follow-up with fluorescence diffuse optical tomography. , 2008, Journal of biomedical optics.

[22]  Ville Kolehmainen,et al.  3D shape based reconstruction of experimental data in Diffuse Optical Tomography. , 2009, Optics express.

[23]  Vasilis Ntziachristos,et al.  Free-space fluorescence molecular tomography utilizing 360° geometry projections , 2007 .

[24]  Miguel Moscoso,et al.  Fluorescence lifetime imaging from time resolved measurements using a shape-based approach. , 2009, Optics express.

[25]  Vasilis Ntziachristos,et al.  Hybrid System for Simultaneous Fluorescence and X-Ray Computed Tomography , 2010, IEEE Transactions on Medical Imaging.

[26]  M. Schweiger,et al.  The finite element method for the propagation of light in scattering media: boundary and source conditions. , 1995, Medical physics.

[27]  S R Arridge,et al.  3D level set reconstruction of model and experimental data in Diffuse Optical Tomography. , 2010, Optics express.

[28]  K. Vasquez,et al.  Quantitative Whole Body Biodistribution of Fluorescent-Labeled Agents by Non-Invasive Tomographic Imaging , 2011, PloS one.

[29]  Vasilis Ntziachristos,et al.  Optimization of 360° projection fluorescence molecular tomography , 2007, Medical Image Anal..

[30]  Sophie J Deharvengt,et al.  Dynamic dual-tracer MRI-guided fluorescence tomography to quantify receptor density in vivo , 2013, Proceedings of the National Academy of Sciences.

[31]  Yubo Fan,et al.  Fluorescence molecular tomography using a two-step three-dimensional shape-based reconstruction with graphics processing unit acceleration. , 2012, Applied optics.

[32]  Vasilis Ntziachristos,et al.  Accuracy of fluorescent tomography in the presence of heterogeneities:study of the normalized born ratio , 2005, IEEE Transactions on Medical Imaging.

[33]  Gultekin Gulsen,et al.  Quantitative fluorescence tomography with functional and structural a priori information. , 2009, Applied optics.

[34]  R. Leahy,et al.  Joint L1 and total variation regularization for fluorescence molecular tomography , 2012, Physics in medicine and biology.