Amperometric biosensor system for simultaneous determination of adenosine-5'-triphosphate and glucose.

The majority of biosensors for adenosine-5'-triphosphate (ATP) determination are based on cascades of enzymatic reactions; therefore, they are sensitive to glucose or glycerol (depending on the enzymatic system) as well as to ATP. The presence of unknown concentrations of these substances in the sample greatly complicates the determination of ATP. To overcome this disadvantage of known biosensors, we developed a biosensor system consisting of two biosensors: the first one is based on glucose oxidase and is intended for measuring glucose concentration, and the second one is based on glucose oxidase and hexokinase and is sensitive toward both glucose and ATP. Using glucose concentration measured by the first biosensor, we can analyze the total response to glucose and ATP obtained by the second biosensor. Platinum disc electrodes were used as amperometric transducers. The polyphenilenediamine membrane was deposited onto the surface of platinum electrodes to avoid the response to electroactive substances. The effect of glucose concentration on biosensor determination of ATP was studied. The reproducibility of biosensor responses to glucose and ATP during a day was tested (relative standard deviation, RSD, of responses to glucose was 3-6% and to ATP was 8-12%) as well as storage stability of the biosensors (no decrease of glucose responses and 43% drop of ATP responses during 50 days). The measurements of ATP and glucose in pharmaceutical vials (including mixtures of ATP and glucose) were carried out. It was shown that the developed biosensor system can be used for simultaneous analysis of glucose and ATP concentrations in water solutions.

[1]  B. Mizaikoff,et al.  Amperometric ATP biosensor based on polymer entrapped enzymes. , 2004, Biosensors & bioelectronics.

[2]  S. Cosnier,et al.  Electrosynthesized polymers for biosensing. , 2011, Chemical Society reviews.

[3]  A. Soldatkin,et al.  Microbiosensor based on glucose oxidase and hexokinase co-immobilised on platinum microelectrode for selective ATP detection. , 2009, Talanta.

[4]  Sonja Hatz,et al.  Microelectrode biosensor for real-time measurement of ATP in biological tissue. , 2005, Analytical chemistry.

[5]  A. Soldatkin,et al.  Highly selective microbiosensors for in vivo measurement of glucose, lactate and glutamate. , 2006, Analytica chimica acta.

[6]  J. Haginaka,et al.  Determination of ATP and its metabolites released from rat caudal artery by isocratic ion-pair reversed-phase high-performance liquid chromatography. , 1998, Analytical biochemistry.

[7]  G. Guilbault,et al.  Glucose oxidase/hexokinase electrode for the determination of ATP , 1997 .

[8]  Measurement of purine release with microelectrode biosensors , 2012, Purinergic Signalling.

[9]  F. Scheller,et al.  Glucose oxidase—hexokinase bienzyme electrode sensor for adenosine triphosphate , 1980 .

[10]  A. Lehninger Principles of Biochemistry , 1984 .

[11]  Tomoya Tanaka,et al.  Enzyme-based Field-Effect Transistor for Adenosine Triphosphate (ATP) Sensing , 2007, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[12]  Yueming Sun,et al.  Co-immobilization of glucose oxidase and hexokinase on silicate hybrid sol-gel membrane for glucose and ATP detections. , 2007, Biosensors & bioelectronics.

[13]  Isao Karube,et al.  A microsensor for adenosine-5′-triphosphate pH-sensitive field effect transistors , 1986 .

[14]  R. O'Neill,et al.  Characterization of permselective coatings electrosynthesized on Pt–Ir from the three phenylenediamine isomers for biosensor applications , 2008 .

[15]  Hans Ulrich Bergmeyer,et al.  Methods of Enzymatic Analysis , 2019 .