Load-Damping Characteristic Control Method in an Isolated Power System With Industrial Voltage-Sensitive Load

Load-damping characteristic models the load response to the frequency deviation, which has important impact on system frequency response. The load-damping coefficient is normally considered as a constant, obtained from operational experiences in large-scale power systems or from detailed load models in isolated power systems. An industrial isolated power system for aluminum production driven by coal-fired power and large scale wind power is studied in this paper. Since the electrolytic aluminum load is driven by direct current, it is one type of voltage-sensitive load and does not respond to the frequency deviation. This paper proposes a load-damping characteristic control method for such isolated industrial power system with voltage-sensitive load. To decrease the maximum frequency deviation during transient process, a time-varying load-damping coefficient control scheme is presented. Simulation is done on real-time digital simulator (RTDS) and the results verify the effectiveness of the proposed control method.

[1]  P. M. Anderson,et al.  A low-order system frequency response model , 1990 .

[2]  Hao Jiang,et al.  Demand Side Frequency Control Scheme in an Isolated Wind Power System for Industrial Aluminum Smelting Production , 2014, IEEE Transactions on Power Systems.

[3]  Francois Bouffard,et al.  A methodology to study the impact of an increasingly nonconventional load mix on primary frequency control , 2009, 2009 IEEE Power & Energy Society General Meeting.

[4]  Frieder Borggrefe,et al.  The potential of demand-side management in energy-intensive industries for electricity markets in Germany , 2011 .

[5]  S. Ihara,et al.  Load Representation in Power System Stability Studies , 1982, IEEE Transactions on Power Apparatus and Systems.

[6]  Mi Zhou,et al.  An Isolated Industrial Power System Driven by Wind-Coal Power for Aluminum Productions: A Case Study of Frequency Control , 2015, IEEE Transactions on Power Systems.

[7]  J. C. Sabonnadiere,et al.  Structural Analysis of the Electrical System: Application to Secondary Voltage Control in France , 1989, IEEE Power Engineering Review.

[8]  Bob Voller Early Aluminum Production in the Pacific Northwest [History] , 2010, IEEE Industry Applications Magazine.

[9]  V. Terzija,et al.  Adaptive underfrequency load shedding based on the magnitude of the disturbance estimation , 2006, IEEE Transactions on Power Systems.

[10]  P. M. Anderson,et al.  An adaptive method for setting underfrequency load shedding relays , 1992 .

[11]  Bob Voller Early Aluminum Production in the Pacific Northwest , 2010 .

[12]  F. Fernandez-Bernal,et al.  Maximum Frequency Deviation Calculation in Small Isolated Power Systems , 2009, IEEE Transactions on Power Systems.

[13]  S. Ashok,et al.  Peak Load Management in Electrolytic Process Industries , 2008, IEEE Transactions on Power Systems.

[14]  Xu Jian,et al.  An Industrial System Powered by Wind and Coal for Aluminum Production: A Case Study of Technical Demonstration and Economic Feasibility , 2012 .

[15]  Vladimir Terzija Adaptive underfrequency load shedding based on the magnitude of the disturbance estimation , 2006 .

[16]  J. M Varah,et al.  Computational methods in linear algebra , 1984 .

[17]  Fangxing Li,et al.  Sensitivity Analysis of Load-Damping Characteristic in Power System Frequency Regulation , 2013, IEEE Transactions on Power Systems.

[18]  Granville Sewell Computational Methods of Linear Algebra: Sewell/Computational , 2005 .

[19]  Lei Huang,et al.  Optimal PMU Placement Considering Controlled Islanding of Power System , 2014, IEEE Transactions on Power Systems.

[20]  Hau-Ren Lu,et al.  A Two-Way Direct Control of Central Air-Conditioning Load Via the Internet , 2009, IEEE Transactions on Power Delivery.

[21]  James S. Thorp,et al.  Synchronized Phasor Measurement Applications in Power Systems , 2010, IEEE Transactions on Smart Grid.

[22]  Chao Lu,et al.  Design and experiment of wide area HVDC supplementary damping controller considering time delay in China southern power grid , 2009 .

[23]  Innocent Kamwa,et al.  Wide-area measurement based stabilizing control of large power systems-a decentralized/hierarchical approach , 2001 .

[24]  P. Kundur,et al.  Power system stability and control , 1994 .

[25]  J. C. Sabonnadiere,et al.  Structural analysis of the electrical system , 1989 .