Performance analysis of liquid desiccant dehumidification systems

Desiccant systems find applications in a very large variety of industrial and daily usage products including the new HVAC installations. An overview of liquid desiccant technology has been presented in this paper along with a compilation of experimental performance data of liquid desiccant dehumidifiers, empirical dehumidification effectiveness and mass transfer correlations in a useful and easy to read tabular format. The latest trends in this area suggest that hybrid systems are of current interest to HVAC industry, not only for high latent load applications but also for improving indoor air quality. The paper presents a comprehensive comparative parametric analysis of packed bed dehumidifiers for three commonly used desiccant materials viz. triethylene glycol, lithium chloride and calcium chloride, using empirical correlations for dehumidification effectiveness from the literature. The analysis reveals significant variations and anomalies in trends between the predictions by various correlations for the same operating conditions, and highlights the need for benchmarking the performance of desiccant dehumidifiers.

[1]  Tsair-Wang Chung,et al.  Predictions of moisture removal efficiencies for packed-bed dehumidification systems , 1994 .

[2]  M. Sadasivam,et al.  Experimental Investigations on the Thermal Effects in Packed Bed Liquid Desiccant Dehumidifiers , 1994 .

[3]  D. Yogi Goswami,et al.  Effectiveness of Heat and Mass Transfer Processes in a Packed Bed Liquid Desiccant Dehumidifier/Regenerator , 2000 .

[4]  K. Y. Qu,et al.  Experimental study on mass transfer performances of cross flow dehumidifier using liquid desiccant , 2006 .

[5]  Wasim Saman,et al.  An experimental study of a cross-flow type plate heat exchanger for dehumidification/cooling , 2002 .

[6]  Esam Elsarrag,et al.  Design Guidelines and Performance Study on a Structured Packed Liquid Desiccant Air-Conditioning System , 2005 .

[7]  Esam Elsarrag Dehumidification of Air by Chemical Liquid Desiccant in a Packed Column and Its Heat and Mass Transfer Effectiveness , 2006 .

[8]  N. E. Wijeysundera,et al.  Performance study of a falling-film absorber with a film-inverting configuration , 2003 .

[9]  Manuel R. Conde,et al.  Properties of aqueous solutions of lithium and calcium chlorides: formulations for use in air conditioning equipment design , 2004 .

[10]  Yong Tae Kang,et al.  The effect of micro-scale surface treatment on heat and mass transfer performance for a falling film H2O/LiBr absorber , 2003 .

[11]  Palanichamy Gandhidasan A simplified model for air dehumidification with liquid desiccant , 2004 .

[12]  G. Scalabrin,et al.  A Liquid Sorption-Desorption System for Air Conditioning With Heat at Lower Temperature , 1990 .

[13]  M. Meckler,et al.  Evaluation of a liquid-desiccant-enhanced heat-pipe air preconditioner , 1994 .

[14]  Palanichamy Gandhidasan Performance analysis of an open-cycle liquid desiccant cooling system using solar energy for regeneration , 1994 .

[15]  Kambiz Vafai,et al.  Analysis of heat and mass transfer between air and falling film in a cross flow configuration , 2004 .

[16]  D. Yogi Goswami,et al.  Principles of Solar Engineering , 1978 .

[17]  D. Goswami,et al.  Study of an aqueous lithium chloride desiccant system: air dehumidification and desiccant regeneration , 2002 .

[18]  Arshad Y. Khan,et al.  Cooling and dehumidification performance analysis of internally-cooled liquid desiccant absorbers , 1998 .

[19]  John R. Howell,et al.  The Performance of Various Types of Regenerators for Liquid Desiccants , 1981 .

[20]  Farid Nasir Ani,et al.  The Effect of Absorber Packing Height on the Performance of a Hybrid Liquid Desiccant System , 2005 .

[21]  John R. Howell,et al.  Analysis and Design of Efficient Absorbers for Low-Temperature Desiccant Air Conditioners , 1981 .

[22]  Palanichamy Gandhidasan,et al.  Analysis of Heat and Mass Transfer Between a Desiccant-Air System in a Packed Tower , 1987 .

[23]  K. Y. Qu,et al.  Empirical correlations to predict the performance of the dehumidifier using liquid desiccant in heat and mass transfer , 2006 .

[24]  J. Duffie,et al.  Cooling with solar energy , 1961 .

[25]  Terry G. Lenz,et al.  Performance studies for an experimental solar open-cycle liquid desiccant air dehumidification system , 1990 .

[26]  † and Tsair-Wang Chung,et al.  Comparison between Spray Towers with and without Fin Coils for Air Dehumidification Using Triethylene Glycol Solutions and Development of the Mass-Transfer Correlations , 2000 .

[27]  Kambiz Vafai,et al.  Comparative study between parallel and counter flow configurations between air and falling film desiccant in the presence of nanoparticle suspensions , 2003 .

[28]  S. C. Kaushik,et al.  Evaluation of solid-desiccant-based evaporative cooling cycles for typical hot and humid climates , 1995 .

[29]  D. Y. Goswami,et al.  Experimental Study of the Heat and Mass Transfer in a Packed Bed Liquid Desiccant Air Dehumidifier , 1998 .

[30]  P. Davies A solar cooling system for greenhouse food production in hot climates , 2005 .

[31]  S. C. Kaushik,et al.  Optimal design of liquid desiccant cooling systems , 2000 .

[32]  Sabah A. Abdul-Wahab,et al.  Air dehumidification by triethylene glycol desiccant in a packed column , 2004 .

[33]  Omar M. Al-Rabghi,et al.  Proposed energy-efficient air-conditioning system using liquid desiccant , 1996 .

[34]  Esam Elsarrag,et al.  Performance study on a structured packed liquid desiccant regenerator , 2006 .

[35]  S. C. Kaushik,et al.  Experimental studies on the dehumidifier and regenerator of a liquid desiccant cooling system , 2000 .

[36]  P. Gandhidasan Quick performance prediction of liquid desiccant regeneration in a packed bed , 2005 .

[37]  Moustafa M. Elsayed,et al.  Effectiveness of heat and mass transfer in packed beds of liquid desiccant system , 1993 .

[38]  Sabah A. Abdul-Wahab,et al.  Predictions of moisture removal rate and dehumidification effectiveness for structured liquid desiccant air dehumidifier , 2004 .

[39]  Hiroshi Takeuchi,et al.  MASS TRANSFER COEFFICIENTS BETWEEN GAS AND LIQUID PHASES IN PACKED COLUMNS , 1968 .

[40]  Abdulghani A. Al-Farayedhi,et al.  Thermodynamic analysis of liquid desiccants , 1998 .

[41]  Abdulghani A. Al-Farayedhi,et al.  Evaluation of heat and mass transfer coefficients in a gauze-type structured packing air dehumidifier operating with liquid desiccant , 2002 .

[42]  Pedro J. Mago,et al.  A study of the performance of a hybrid liquid desiccant cooling system using lithium chloride , 2001 .

[43]  Tsair-Wang Chung,et al.  Comparison between Random and Structured Packings for Dehumidification of Air by Lithium Chloride Solutions in a Packed Column and Their Heat and Mass Transfer Correlations , 1996 .

[44]  G. Grossman,et al.  A packed bed dehumidifier/regenerator for solar air conditioning with liquid desiccants , 1980 .

[45]  Tsair-Wang Chung,et al.  Vapor pressures of the aqueous desiccants , 1999 .

[46]  S. Jain,et al.  Mass-Transfer Correlations for Dehumidification of Air by Triethylene Glycol in a Structured Packed Column , 2004 .

[47]  K. Daou,et al.  Desiccant cooling air conditioning : a review , 2006 .

[48]  G. Longo,et al.  Experimental and theoretical analysis of heat and mass transfer in a packed column dehumidifier/regenerator with liquid desiccant , 2005 .

[49]  D. Y. Goswami,et al.  A review of liquid desiccant cooling , 1998 .

[50]  Ruzhu Wang,et al.  Use of liquid desiccant cooling to improve the performance of vapor compression air conditioning , 2001 .

[51]  Ursula Eicker,et al.  Experimental performance analysis and modelling of liquid desiccant cooling systems for air conditioning in residential buildings , 2006 .

[52]  A. Ertas,et al.  Properties of a new liquid desiccant solution—Lithium chloride and calcium chloride mixture , 1992 .

[53]  G. Longo,et al.  Chemical dehumidification by liquid desiccants: theory and experiment , 1999 .

[54]  James E. Braun,et al.  An effectiveness model of liquid-desiccant system heat/mass exchangers , 1989 .

[55]  S. C. Kaushik,et al.  Evaluation of liquid dessicant based evaporative cooling cycles for typical hot and humid climates , 1994 .