Fire behaviour of concrete filled elliptical steel columns

In this work, a non-linear three-dimensional finite element model is presented in order to study the behaviour of axially loaded concrete filled elliptical hollow section (CFEHS) columns exposed to fire. This study builds on previous work carried out by the authors on concrete filled circular hollow section (CFCHS) columns both at room temperature and in fire. The numerical model is first validated at room temperature against a series of experiments on CFEHS stub columns available in the literature and subsequently extended to study the performance of slender columns at elevated temperatures. The aim of this work is to understand and represent the behaviour of axially loaded CFEHS columns in fire situations and to compare their effectiveness with that of the circular concrete filled tubular (CFT) columns. Parametric studies to explore the influence of variation in global member slenderness, load level, cross-section slenderness and section size are presented. Finally, guidance on the fire design of CFEHS columns is proposed: it is recommended to follow the guidelines of Clause 4.3.5.1 in EN 1994-1-2, but employing the flexural stiffness reduction coefficients established in the French National Annex with an equivalent EHS diameter equal to P/π, where P is the perimeter of the ellipse.

[1]  Chanakya Arya,et al.  Eurocodes 2: Design of concrete structures , 2009 .

[2]  T. Lie Fire Resistance of Circular Steel Columns Filled with Bar‐Reinforced Concrete , 1994 .

[3]  Tak-Ming Chan,et al.  Cross-section classification of elliptical hollow sections , 2007 .

[4]  Dennis Lam Steel Concrete Composite and Hybrid Structures , 2009 .

[5]  J M Aribert,et al.  Simplified fire design for composite hollow-section columns , 2008 .

[6]  Xianghe Dai,et al.  Numerical modelling of the axial compressive behaviour of short concrete-filled elliptical steel columns , 2010 .

[7]  L. P. Saenz Discussion of Equation for the Stress-strain Curve of Concrete by Desayi and Krishman , 1964 .

[8]  Chanakya Arya,et al.  Eurocode 3: Design of steel structures , 2018, Design of Structural Elements.

[9]  J. Mander,et al.  Theoretical stress strain model for confined concrete , 1988 .

[10]  Manuel L. Romero,et al.  Experimental study of high strength concrete-filled circular tubular columns under eccentric loading , 2011 .

[11]  Hsuan-Teh Hu,et al.  NONLINEAR ANALYSIS OF AXIALLY LOADED CONCRETE-FILLED TUBE COLUMNS WITH CONFINEMENT EFFECT , 2003 .

[12]  Xianghe Dai,et al.  Modelling the Confinement Effect of Composite Concrete-Filled Elliptical Steel Columns , 2009 .

[13]  Amit H. Varma,et al.  Analytical modeling of the standard fire behavior of loaded CFT columns , 2009 .

[14]  Leroy Gardner,et al.  Testing and analysis of concrete-filled elliptical hollow sections , 2008 .

[15]  L. P. Sanez,et al.  DISCUSSION OF EQUATION FOR THE STRESS - STRAIN CURVE OF CONCRETE’ BY DESAYI AND KRISHNAN , 1964 .

[16]  Tak-Ming Chan,et al.  Flexural Buckling of Elliptical Hollow Section Columns , 2009 .

[17]  Dennis Lam,et al.  Behaviour of normal and high strength concrete-filled compact steel tube circular stub columns , 2006 .

[18]  Jeffrey A. Packer,et al.  Tests and design of concrete-filled elliptical hollow section stub columns , 2009 .

[19]  K. F. Chung,et al.  Composite column design to Eurocode 4 : based on DD ENV 1994-1-1: 1994 Eurocode 4: design of composite steel and concrete structures: part 1.1: general rules and rules for buildings , 1994 .

[20]  Tom Lennon Designers' guide to EN 1991-1-2, EN 1992-1-2, EN 1993-1-2 and EN 1994-1-2 : handbook for the fire design of steel, composite and concrete structures to the eurocodes , 2007 .

[21]  Manuel L. Romero,et al.  Advanced model for predicting the fire response of concrete filled tubular columns , 2010 .

[22]  Tak-Ming Chan,et al.  Shear response of elliptical hollow sections , 2008 .

[23]  Tak-Ming Chan,et al.  Bending strength of hot-rolled elliptical hollow sections , 2008 .

[24]  Leroy Gardner,et al.  Elastic buckling of elliptical tubes , 2008 .

[25]  Nuno Silvestre,et al.  Buckling behaviour of elliptical cylindrical shells and tubes under compression , 2008 .

[26]  J Ding,et al.  REALISTIC MODELLING OF THERMAL AND STRUCTURAL BEHAVIOUR OF UNPROTECTED CONCRETE FILLED TUBULAR COLUMNS IN FIRE , 2008 .

[27]  Luís Simões da Silva,et al.  Design of Steel Structures: Eurocode 3: Design of Steel Structures, Part 1-1: General Rules and Rules for Buildings , 2010 .

[28]  Tak-Ming Chan,et al.  Compressive resistance of hot-rolled elliptical hollow sections , 2008 .