Electric motor thermal management system using L-shaped flat heat pipes

Abstract Heat generation in an electric motor will increase its temperature. The excessive working temperature will reduce the motor performance and shorten its lifetime, therefore, a thermal management system is needed to reduce the working temperature. The objective of this study is to determine the performance of the electric motor thermal management system using L-shaped flat heat pipes experimentally. Evaporator sections of heat pipes are typically placed inside the motor housing or buried in the motor shaft while the condenser sections are placed outside the motor housing and cooled with circulated liquid or air stream. However, in this study, the heat pipes were placed on the surface of the motor housing thus simplifying installation and maintenance. A prototype was made of a 0.5 HP conventional electric motor where the rotor and the coil were replaced by a cartridge heater to simulate the heat generation and to simplify the heat generation adjustment. Eight pieces of L-shaped flat heat pipes were mounted on this prototype. Each evaporator section was mounted on a heat pipe holder that was inserted between the motor fins. Each condenser section was placed in front of the motor fan. Heat sinks were mounted on each condenser section to increase the rate of heat transfer to the ambient air. The heat pipes were made of flattened copper tubes with sintered copper capillary wick and water as working fluid with a filling ratio of 50%. Experiments were conducted with varied heating power while the fan speed was kept constant. The thermal resistance of the motor fins - heat pipe - heat sink did not change much with the heat load. It reached a minimum value of 0.28 °C/W at the heat load of 150 W. The motor surface temperature was reduced from 102.2 °C to 68.4 °C or a reduction by 33.8 °C.

[1]  Nandy Putra,et al.  Application of nanofluids to a heat pipe liquid-block and the thermoelectric cooling of electronic equipment , 2011 .

[2]  Robert Yu,et al.  Experimental study of oil cooling systems for electric motors , 2015 .

[3]  Nandy Putra,et al.  Thermal performance of biomaterial wick loop heat pipes with water-base Al2O3 nanofluids , 2014 .

[4]  N. Putra,et al.  The Effect of CuO-Water Nanofluid and Biomaterial Wick on Loop Heat Pipe Performance , 2014 .

[5]  Jung-Chang Wang L-type heat pipes application in electronic cooling system , 2011 .

[6]  Hongmin Li,et al.  Cooling of a permanent magnet electric motor with a centrifugal impeller , 2010 .

[7]  Roderick Melnik,et al.  Computational analysis of temperature rise phenomena in electric induction motors , 2003 .

[8]  N. Putra,et al.  Application of Al2O3 Nanofluid on Sintered Copper-Powder Vapor Chamber for Electronic Cooling , 2013 .

[9]  A. Bousbaine Thermal Modelling of Induction Motors Based on Accurate Loss Density Distribution , 1999 .

[10]  Kea-Ho Lee,et al.  Development of an interior permanent magnet motor through rotor cooling for electric vehicles , 2016 .

[11]  Rangga Aji Pamungkas,et al.  Experimental investigation on performance of lithium-ion battery thermal management system using flat plate loop heat pipe for electric vehicle application , 2016 .

[12]  Chih-Chung Chang,et al.  Heat pipe with PCM for electronic cooling , 2011 .

[13]  Nandy Putra,et al.  Thermal performance of screen mesh wick heat pipes with nanofluids , 2012 .

[14]  P. K. Panday,et al.  Experimental study of the cooling of a closed type electric motor , 2000 .

[15]  N. Putra,et al.  Improvement of heat pipe performance through integration of a coral biomaterial wick structure into the heat pipe of a CPU cooling system , 2017 .

[16]  Ben Richard Hughes,et al.  A review of heat pipe systems for heat recovery and renewable energy applications , 2012 .