Dynamic In Vivo Chest X-ray Dark-Field Imaging in Mice

X-ray grating interferometry is a powerful emerging tool in biomedical imaging, providing access to three complementary image modalities. In addition to the conventional attenuation modality, interferometry provides a phase modality, which visualizes soft tissue structures, and a dark-field modality, which relates to the number and size of sub-resolution scattering objects. A particularly strong dark-field signal originates from the alveoli or air sacs in the lung. Dark-field lung radiographs in animal models have already shown increased sensitivity in diagnosing lung diseases, such as lung cancer or emphysema, compared to conventional X-ray chest radiography. However, to date, X-ray dark-field lung imaging has either averaged information over several breaths or has been captured during a breath hold. In this paper, we demonstrate the first time-resolved dark-field imaging of a breath cycle in a mechanically ventilated mouse, in vivo, which was obtained using a grating interferometer. We achieved a time resolution of 0.1 s, visualizing the changes in the dark-field, phase, and attenuation images during inhalation and exhalation. These measurements show that the dark-field signal depends on the air volume and, hence, the alveolar dimensions of the lung. Conducting this type of scan with animal disease models would help to locate the optimum breath point for single-image diagnostic dark-field imaging and could indicate if the changes in the dark-field signal during breath provide a diagnostically useful complementary measure.

[1]  Franz Pfeiffer,et al.  In-vivo X-ray Dark-Field Chest Radiography of a Pig , 2017, Scientific Reports.

[2]  Franz Pfeiffer,et al.  Emphysema diagnosis using X-ray dark-field imaging at a laser-driven compact synchrotron light source , 2012, Proceedings of the National Academy of Sciences.

[3]  M. Marschner,et al.  Helical X-ray phase-contrast computed tomography without phase stepping , 2016, Scientific Reports.

[4]  Bongtae Han,et al.  Advanced iterative algorithm for phase extraction of randomly phase-shifted interferograms. , 2004, Optics letters.

[5]  Atsushi Momose,et al.  Four-dimensional X-ray phase tomography with Talbot interferometry and white synchrotron radiation: dynamic observation of a living worm. , 2011, Optics express.

[6]  Esarey,et al.  Nonlinear Thomson scattering of intense laser pulses from beams and plasmas. , 1993, Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics.

[7]  Franz Pfeiffer,et al.  Visualization of neonatal lung injury associated with mechanical ventilation using x-ray dark-field radiography , 2016, Scientific Reports.

[8]  Martin Donnelley,et al.  Animals In Synchrotrons: Overcoming Challenges For High‐Resolution, Live, Small‐Animal Imaging , 2010 .

[9]  M. Olbinado,et al.  X-ray Talbot-Lau interferometer for high-speed phase imaging and tomography using white synchrotron radiation , 2012 .

[10]  Demonstration of Stroboscopic X-ray Talbot Interferometry Using Polychromatic Synchrotron and Laboratory X-ray Sources , 2013 .

[11]  V. Ntziachristos,et al.  Quantitative detection of drug dose and spatial distribution in the lung revealed by Cryoslicing Imaging. , 2015, Journal of pharmaceutical and biomedical analysis.

[12]  Franz Pfeiffer,et al.  Improved In vivo Assessment of Pulmonary Fibrosis in Mice using X-Ray Dark-Field Radiography , 2015, Scientific Reports.

[13]  G. D'Alonzo,et al.  The Radiology Handbook: A Pocket Guide to Medical Imaging , 2007 .

[14]  Franz Pfeiffer,et al.  Pulmonary emphysema diagnosis with a preclinical small-animal X-ray dark-field scatter-contrast scanner. , 2013, Radiology.

[15]  Esarey,et al.  Thomson scattering of intense lasers from electron beams at arbitrary interaction angles. , 1995, Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics.

[16]  O. Bunk,et al.  Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .

[17]  Kentaro Uesugi,et al.  4D x-ray phase contrast tomography for repeatable motion of biological samples. , 2016, The Review of scientific instruments.

[18]  Franz Pfeiffer,et al.  Diagnosing and Mapping Pulmonary Emphysema on X-Ray Projection Images: Incremental Value of Grating-Based X-Ray Dark-Field Imaging , 2013, PloS one.

[19]  Franz Pfeiffer,et al.  X-ray dark-field and phase-contrast imaging using a grating interferometer , 2009 .

[20]  Sub-10-ms X-ray tomography using a grating interferometer , 2017 .

[21]  Franz Pfeiffer,et al.  Hard X-ray phase-contrast imaging with the Compact Light Source based on inverse Compton X-rays. , 2009, Journal of synchrotron radiation.

[22]  Franz Pfeiffer,et al.  In Vivo Dark-Field Radiography for Early Diagnosis and Staging of Pulmonary Emphysema , 2015, Investigative radiology.

[23]  Franz Pfeiffer,et al.  The Munich Compact Light Source: initial performance measures. , 2016, Journal of synchrotron radiation.

[24]  Franz Pfeiffer,et al.  Trabecular bone anisotropy imaging with a compact laser-undulator synchrotron x-ray source , 2017, Scientific Reports.

[25]  R. Loewen,et al.  A compact light source: Design and technical feasibility study of a laser-electron storage ring X-ray source , 2004 .

[26]  O. Bunk,et al.  Hard-X-ray dark-field imaging using a grating interferometer. , 2008, Nature materials.

[27]  Franz Pfeiffer,et al.  X-ray Dark-field Radiography - In-Vivo Diagnosis of Lung Cancer in Mice , 2017, Scientific Reports.

[28]  F. Pfeiffer,et al.  Propagation-based Phase-Contrast X-ray Imaging at a Compact Light Source , 2017, Scientific Reports.

[29]  Kentaro Uesugi,et al.  Quantitative and dynamic measurements of biological fresh samples with X-ray phase contrast tomography , 2014, Journal of synchrotron radiation.

[30]  Franz Pfeiffer,et al.  Facilitated Diagnosis of Pneumothoraces in Newborn Mice Using X-ray Dark-Field Radiography , 2016, Investigative radiology.

[31]  J. Boone,et al.  Small-animal X-ray dose from micro-CT. , 2004, Molecular imaging.