The influence of patient size on dose conversion coefficients: a hybrid phantom study for adult cardiac catheterization.

In this study, the influence of patient size on organ and effective dose conversion coefficients (DCCs) was investigated for a representative interventional fluoroscopic procedure-cardiac catheterization. The study was performed using hybrid phantoms representing an underweight, average and overweight American adult male. Reference body sizes were determined using the NHANES III database and parameterized based on standing height and total body mass. Organ and effective dose conversion coefficients were calculated for anterior-posterior, posterior-anterior, left anterior oblique and right anterior oblique projections using the Monte Carlo code MCNPX 2.5.0 with the metric dose area product being used as the normalization factor. Results show body size to have a clear influence on DCCs which increased noticeably when body size decreased. It was also shown that if patient size is neglected when choosing a DCC, the organ and effective dose will be underestimated to an underweight patient and will be overestimated to an underweight patient, with errors as large as 113% for certain projections. Results were further compared with those published for a KTMAN-2 Korean patient-specific tomographic phantom. The published DCCs aligned best with the hybrid phantom which most closely matched in overall body size. These results highlighted the need for and the advantages of phantom-patient matching, and it is recommended that hybrid phantoms be used to create a more diverse library of patient-dependent anthropomorphic phantoms for medical dose reconstruction.

[1]  K. Eckerman,et al.  Response functions for computing absorbed dose to skeletal tissues from photon irradiation. , 2007, Radiation protection dosimetry.

[2]  J. Valentin Basic anatomical and physiological data for use in radiological protection: reference values , 2002, Annals of the ICRP.

[3]  M. Zankl,et al.  Influence of Patient Size on Organ Doses in Diagnostic Radiology , 1992 .

[4]  B. Wall,et al.  Estimation of effective dose in diagnostic radiology from entrance surface dose and dose-area product measurements , 1994 .

[5]  M. Charles ICRP Publication 103: Recommendations of the ICRP , 2007 .

[6]  M. Zankl,et al.  Variation of Organ Doses in Paediatric Radiology due to Patient Diameter, Calculated with Phantoms of Varying Voxel Size , 1993 .

[7]  S. Evans Catalogue of Diagnostic X-Ray Spectra and Other Data , 1998 .

[8]  A. Bozkurt,et al.  Simultaneous determination of equivalent dose to organs and tissues of the patient and of the physician in interventional radiology using the Monte Carlo method , 2007, Physics in medicine and biology.

[9]  Jai-Ki Lee,et al.  Development of the two Korean adult tomographic computational phantoms for organ dosimetry. , 2006, Medical physics.

[10]  Chuan-Jong Tung,et al.  Body size-dependent patient effective dose for diagnostic radiography , 2008 .

[11]  K. Eckerman Aspects of the dosimetry of radionuclides within the skeleton with particular emphasis on the active marrow , 1985 .

[12]  Wesley E Bolch,et al.  Age-dependent organ and effective dose coefficients for external photons: a comparison of stylized and voxel-based paediatric phantoms , 2006, Physics in medicine and biology.

[13]  R. Sievert,et al.  Book Reviews : Recommendations of the International Commission on Radiological Protection (as amended 1959 and revised 1962). I.C.R.P. Publication 6. 70 pp. PERGAMON PRESS. Oxford, London and New York, 1964. £1 5s. 0d. [TB/54] , 1964 .

[14]  J. K. Lee,et al.  Dose conversion coefficients calculated using tomographic phantom, KTMAN-2, for X-ray examination of cardiac catheterisation. , 2007, Radiation protection dosimetry.

[15]  Deanna Hasenauer,et al.  Hybrid computational phantoms of the male and female newborn patient: NURBS-based whole-body models , 2007, Physics in medicine and biology.

[16]  James A. Scott Photon, Electron, Proton and Neutron Interaction Data for Body Tissues ICRU Report 46. International Commission on Radiation Units and Measurements, Bethesda, 1992, $40.00 , 1993 .

[17]  Wesley E Bolch,et al.  Anthropometric approaches and their uncertainties to assigning computational phantoms to individual patients in pediatric dosimetry studies , 2008, Physics in medicine and biology.

[18]  J Hausleiter,et al.  Local organ dose conversion coefficients for angiographic examinations of coronary arteries , 2007, Physics in medicine and biology.