Convergence Analysis of an Iterative Targeting Method for Keyhole Robotic Surgery

In surgical procedures, robots can accurately position and orient surgical instruments. Intraoperatively, external sensors can localize the instrument and compute the targeting movement of the robot, based on the transformation between the coordinate frame of the robot and the sensor. This paper addresses the assessment of the robustness of an iterative targeting algorithm in perturbed conditions. Numerical simulations and experiments (with a robot with seven degrees of freedom and an optical tracking system) were performed for computing the maximum error of the rotational part of the calibration matrix, which allows for convergence, as well as the number of required iterations. The algorithm converges up to 50 degrees of error within a large working space. The study confirms the clinical relevance of the method because it can be applied on commercially available robots without modifying the internal controller, thus improving the targeting accuracy and meeting surgical accuracy requirements.

[1]  Peter Kazanzides,et al.  An integrated system for planning, navigation and robotic assistance for skull base surgery , 2008, The international journal of medical robotics + computer assisted surgery : MRCAS.

[2]  Paul S. Morgan,et al.  The application accuracy of the PathFinder neurosurgical robot , 2003, CARS.

[3]  Leo Joskowicz,et al.  Bone-mounted miniature robot for surgical procedures: Concept and clinical applications , 2003, IEEE Trans. Robotics Autom..

[4]  Alexander Schlaefer,et al.  Robust real‐time robot–world calibration for robotized transcranial magnetic stimulation , 2011, The international journal of medical robotics + computer assisted surgery : MRCAS.

[5]  Kostas Daniilidis,et al.  Hand-Eye Calibration Using Dual Quaternions , 1999, Int. J. Robotics Res..

[6]  William Main,et al.  An Analysis of the Accuracy of the CyberKnife: A Robotic Frameless Stereotactic Radiosurgical System , 2003, Neurosurgery.

[7]  Giancarlo Ferrigno,et al.  Accurate multi-robot targeting for keyhole neurosurgery based on external sensor monitoring , 2012, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[8]  Yang Shi,et al.  Modeling and Robust Discrete-Time Sliding-Mode Control Design for a Fluid Power Electrohydraulic Actuator (EHA) System , 2013 .

[9]  Hiep T Nguyen,et al.  Robotic Surgery in Otolaryngology and Head and Neck Surgery: A Review , 2012, Minimally invasive surgery.

[10]  Rupesh Tarwala,et al.  Robotic assisted total hip arthroplasty using the MAKO platform , 2011, Current reviews in musculoskeletal medicine.

[11]  Alin Albu-Schäffer,et al.  The KUKA-DLR Lightweight Robot arm - a new reference platform for robotics research and manufacturing , 2010, ISR/ROBOTIK.

[12]  Abhilash Pandya,et al.  The application accuracy of the NeuroMate robot--A quantitative comparison with frameless and frame-based surgical localization systems. , 2002, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[13]  Jay B. West,et al.  Designing optically tracked instruments for image-guided surgery , 2004, IEEE Transactions on Medical Imaging.

[14]  P N Brett,et al.  ENT challenges at the small scale , 2007, The international journal of medical robotics + computer assisted surgery : MRCAS.

[15]  M S Eljamel Validation of the PathFinder™ neurosurgical robot using a phantom , 2007, The international journal of medical robotics + computer assisted surgery : MRCAS.

[16]  Hideki Yoshikawa,et al.  Clinical accuracy evaluation of femoral canal preparation using the ROBODOC system , 2004, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[17]  M. Cenk Cavusoglu,et al.  Regular Paper Submission for the Ieee Transactions on Mechatronics Design of a Parallel Robot for Needle Based Interventions on Small Animals¨ozkan , 2022 .

[18]  Giancarlo Ferrigno,et al.  Optically tracked multi-robot system for keyhole neurosurgery , 2011, 2011 IEEE International Conference on Robotics and Automation.

[19]  Robert Bicker,et al.  Design of a robotic Transcranial Magnetic Stimulation system , 2010, 2010 IEEE Conference on Robotics, Automation and Mechatronics.

[20]  M. Eljamel,et al.  Robotic Neurological Surgery Applications: Accuracy and Consistency or Pure Fantasy? , 2009, Stereotactic and Functional Neurosurgery.

[21]  J. Cornella,et al.  Improving Cartesian position Accuraca of a telesurgical robot , 2008, 2008 IEEE International Symposium on Industrial Electronics.

[22]  W. Sukovich,et al.  Miniature robotic guidance for pedicle screw placement in posterior spinal fusion: early clinical experience with the SpineAssist® , 2006, The international journal of medical robotics + computer assisted surgery : MRCAS.

[23]  A. Lanfranco,et al.  Robotic Surgery: A Current Perspective , 2004, Annals of surgery.

[24]  Benjamin Movsas,et al.  Image-Guided Target Localization for Stereotactic Radiosurgery:Accuracy of 6D versus 3D Image Fusion , 2006 .

[25]  Giancarlo Ferrigno,et al.  Robotic alignment of femoral cutting mask during total knee arthroplasty , 2008, International Journal of Computer Assisted Radiology and Surgery.

[26]  Eric L. Lin,et al.  The use of the three-pronged Mayfield head clamp resulting in an intracranial epidural hematoma in an adult patient , 2010, European Spine Journal.

[27]  Fadi Dornaika,et al.  Hand-Eye Calibration , 1995, Int. J. Robotics Res..

[28]  Z. Benyo,et al.  Event-based patient motion detection and compensation in image-guided robotics , 2012, 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob).

[29]  M Shoham,et al.  Image-guided system with miniature robot for precise positioning and targeting in keyhole neurosurgery , 2006, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[30]  Gerd Hirzinger,et al.  Optimal Hand-Eye Calibration , 2006, 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[31]  Leo Joskowicz,et al.  Localization and registration accuracy in image guided neurosurgery: a clinical study , 2008, International Journal of Computer Assisted Radiology and Surgery.

[32]  Giovanni Legnani,et al.  Hand to sensor calibration: A geometrical interpretation of the matrix equation AXXB , 2005, J. Field Robotics.