Development of a Protocol for CCD Calibration: Application to a Multispectral Imaging System

In this paper we describe in detail a method for calibrating a CCD-based camera. The calibration aims to remove both temporal and systematic noises introduced by the sensor, electronics, and optics after which we can correct the non-linearity of its response. For the non-linearity correction we use a simple and powerful approach consisting on a complementary approach between a polynomial fitting and an LUT based algorithm. The proposed methodology is accurate in the sense that it takes into account individual characteristics of each pixel. In each pixel, systematic noises are measured through acquiring offset images, thermal images, and FlatField images. A rigorous protocol for acquiring these images based on experimentation is established. The method to acquire Flat-Field image is novel and is particularly efficient in that it can correct all defects due to non-uniform pixel responses, vignettage, blemishes on optic and/or filters, and perhaps even illumination nonuniformity. We notice that such a methodology of calibration is particularly efficient in the case of an optical filter based multispectral imaging system, although it remains valid for any imaging system based on a CCD sensor.

[1]  H.A. Beyer,et al.  Accurate calibration of CCD-cameras , 1992, Proceedings 1992 IEEE Computer Society Conference on Computer Vision and Pattern Recognition.

[2]  Mark S. Robinson,et al.  Inflight calibration of the NEAR multispectral imager: II. Results from Eros approach and orbit , 2002 .

[3]  Theo Gevers,et al.  Color Measurement by Imaging Spectrometry , 2000, Comput. Vis. Image Underst..

[4]  Gerrit Polder,et al.  Calibration and characterization of spectral imaging systems , 2001, International Symposium on Multispectral Image Processing and Pattern Recognition.

[5]  Shree K. Nayar,et al.  Radiometric self calibration , 1999, Proceedings. 1999 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (Cat. No PR00149).

[6]  Ian T. Young,et al.  Methods for CCD camera characterization , 1994, Electronic Imaging.

[7]  Gideon P. Stein Accurate internal camera calibration using rotation, with analysis of sources of error , 1995, Proceedings of IEEE International Conference on Computer Vision.

[8]  D A Low,et al.  Commissioning and periodic quality assurance of a clinical electronic portal imaging device. , 1996, International journal of radiation oncology, biology, physics.

[10]  Glenn Healey,et al.  Radiometric CCD camera calibration and noise estimation , 1994, IEEE Trans. Pattern Anal. Mach. Intell..

[11]  Robert E. Gold,et al.  Inflight Calibration of the NEAR Multispectral Imager , 1999 .