Assessment of the aortic root using real-time 3D transesophageal echocardiography.

BACKGROUND Precise evaluation of the aortic root geometry prior to transcatheter aortic valve implantation is important for procedural success in patients with aortic stenosis (AS). To determine the potential for 3-dimensional transesophageal echocardiography (3DTEE), the aims of the present study were: (1) to assess the accuracy of 3DTEE measurements of the aortic root using multidetector computed tomography (MDCT) as a reference, and (2) to examine whether aortic root geometry differs between patients with and without AS. METHODS AND RESULTS   3DTEE and contrast-enhanced MDCT were performed in 35 patients. Multiplanar reconstruction was used to measure the left ventricular outflow tract (LVOT) and aortic annulus diameter/area, aortic valve area (AVA), and distances between the annulus and coronary artery ostium. The same 3DTEE measurements were performed in patients with (n=71) and without AS (n=80). Aortic annular and LVOT areas measured by 3DTEE were slightly but significantly smaller compared with values obtained with MDCT. Both methods revealed that the aortic annulus and LVOT have an oval shape. Aortic annular and LVOT area, AVA and the distances between the aortic annulus and the coronary ostia correlated well between the 2 modalities. Only minor differences in aortic root geometry were observed between patients with AS and those without. CONCLUSIONS The geometry of the aortic annulus can be reliably evaluated using 3DTEE as an alternative to MDCT for the assessment of aortic root.

[1]  R. Anderson Clinical anatomy of the aortic root , 2000, Heart.

[2]  J. S. Cavalcanti,et al.  Morphometric and topographic study of coronary ostia. , 2003, Arquivos brasileiros de cardiologia.

[3]  Philippe Ravaud,et al.  A prospective survey of patients with valvular heart disease in Europe: The Euro Heart Survey on Valvular Heart Disease. , 2003, European heart journal.

[4]  Assaf Bash,et al.  Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis. , 2004, Journal of the American College of Cardiology.

[5]  Philippe Ravaud,et al.  Decision-making in elderly patients with severe aortic stenosis: why are so many denied surgery? , 2005, European heart journal.

[6]  Thomas Felderhoff,et al.  Percutaneous Implantation of the CoreValve Self-Expanding Valve Prosthesis in High-Risk Patients With Aortic Valve Disease: The Siegburg First-in-Man Study , 2006, Circulation.

[7]  Thomas Felderhoff,et al.  Percutaneous Implantation of the CoreValve Self-Expanding Valve Prosthesis in High-Risk Patients With Aortic Valve Disease: The Siegburg First-in-Man Study , 2006 .

[8]  A. Cohen-Solal,et al.  Diagnosis of aortic valvular stenosis by multislice cardiac computed tomography. , 2006, European heart journal.

[9]  Robert J Ostfeld,et al.  Demonstration of Left Ventricular Outflow Tract Eccentricity by Real Time 3D Echocardiography: Implications for the Determination of Aortic Valve Area , 2007, Echocardiography.

[10]  Thomas Walther,et al.  Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: device success and 30-day clinical outcome. , 2007, Journal of the American College of Cardiology.

[11]  Scott H. Settlemier,et al.  Live 3-dimensional transesophageal echocardiography initial experience using the fully-sampled matrix array probe. , 2008, Journal of the American College of Cardiology.

[12]  Robert H. Anderson,et al.  Anatomy of the Aortic Valvar Complex and Its Implications for Transcatheter Implantation of the Aortic Valve , 2008, Circulation. Cardiovascular interventions.

[13]  Jacob Geleijns,et al.  Clinical evaluation of 64-slice CT assessment of global left ventricular function using automated cardiac phase selection. , 2008, Circulation journal : official journal of the Japanese Circulation Society.

[14]  Jeroen J. Bax,et al.  Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement. , 2008, JACC. Cardiovascular imaging.

[15]  R. Moss,et al.  Role of echocardiography in percutaneous aortic valve implantation. , 2008, JACC. Cardiovascular imaging.

[16]  V. Jeevanandam,et al.  Real-time three-dimensional transesophageal echocardiography in valve disease: comparison with surgical findings and evaluation of prosthetic valves. , 2008, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[17]  Y. Castier,et al.  Contemporary surgical or percutaneous management of severe aortic stenosis in the elderly. , 2008, European heart journal.

[18]  Y. Neishi,et al.  Clinical implication of energy loss coefficient in patients with severe aortic stenosis diagnosed by Doppler echocardiography. , 2008, Circulation journal : official journal of the Japanese Circulation Society.

[19]  Mark A. Friedman,et al.  Demonstration of left ventricular outflow tract eccentricity by 64-slice multi-detector CT , 2008, The International Journal of Cardiovascular Imaging.

[20]  N. Al-Attar,et al.  Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI). , 2008, European heart journal.

[21]  C. Hamm,et al.  Detection of relevant coronary artery disease using dual-source computed tomography in a high probability patient series: comparison with invasive angiography. , 2009, Circulation journal : official journal of the Japanese Circulation Society.

[22]  H. Kühl,et al.  Real-time three-dimensional transoesophageal echocardiography for guidance of non-coronary interventions in the catheter laboratory. , 2009, European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology.

[23]  Imran Syed,et al.  Real-time three-dimensional transesophageal echocardiography in the intraoperative assessment of mitral valve disease. , 2009, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[24]  D. Chin Echocardiography for transcatheter aortic valve implantation. , 2009, European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology.

[25]  Jeroen J. Bax,et al.  Role of multislice computed tomography in transcatheter aortic valve replacement. , 2009, The American journal of cardiology.

[26]  Vartan Kurtcuoglu,et al.  Remodelling of the aortic root in severe tricuspid aortic stenosis: implications for transcatheter aortic valve implantation , 2009, European Radiology.

[27]  Paul Schoenhagen,et al.  Three-dimensional imaging of the aortic valve and aortic root with computed tomography: new standards in an era of transcatheter valve repair/implantation. , 2009, European heart journal.

[28]  M. Takeuchi,et al.  Three-dimensional transesophageal echocardiographic recognition of mobile mass protruding into the left main coronary orifice in a patient with aortic stenosis. , 2010, Circulation Journal.

[29]  Jeroen J. Bax,et al.  Comparison of Aortic Root Dimensions and Geometries Before and After Transcatheter Aortic Valve Implantation by 2- and 3-Dimensional Transesophageal Echocardiography and Multislice Computed Tomography , 2010, Circulation. Cardiovascular imaging.

[30]  Fabien Hyafil,et al.  Multimodal assessment of the aortic annulus diameter: implications for transcatheter aortic valve implantation. , 2010, Journal of the American College of Cardiology.