A laboratory comparison of four positive pressure ventilators used in the home.

Four brands of ventilator used for noninvasive positive pressure ventilation in the home were assessed to determine their performance on a patient simulator. We tested the tidal volume (VT) preset Companion 2801 (Puritan Bennett), minute volume preset Monnal D (Taema), and two pressure preset ventilators, the Nippy (Friday Medical) and the Bilevel Positive Airway Pressure (BiPAP) (Respironics). A patient simulator was employed to investigate the relationships between VT, peak airway pressure (PAP) and mean airway pressure (MAP), the responses to an additional leak in the circuit and patient effort of a variable duration, which was modelled using a negative pressure pump. For equivalent VTs, >300 mL, the Monnal D and Nippy generated a PAP up to 100% greater than the Companion 2801 and BiPAP. When an additional leak was introduced to the circuit, the VT of the Companion 2801 and Monnal D fell by >50%, while the Nippy and the BiPAP responded by increasing flow and maintained VT close to the level achieved with no leak. When the ventilators were triggered by a simulated patient effort of 0.25 s duration with a frequency 33% greater than that of the ventilator, the minute volume increased by 41% for the Companion 2801, by 18% for the Monnal D (no change expected), and by 17% for the Nippy (less than expected), and fell by 7% for the BiPAP due to irregular triggering. When patient effort was prolonged to 1.5 s, a similar length to the inspiratory time of the ventilators, there was no further change in the minute volume of the Companion 2801 and Monnal D, while that of the Nippy and of the BiPAP increased by 38 and 71%, respectively, compared to baseline. These results show that distinct brands of ventilator respond to changes in the patient and patient circuit in different ways, which are not always predictable from a simple description of their operating principles. This should be borne in mind when choosing a positive pressure ventilator for noninvasive ventilation.

[1]  C. Sullivan,et al.  Treatment of respiratory failure during sleep in patients with neuromuscular disease. Positive-pressure ventilation through a nose mask. , 2015, The American review of respiratory disease.

[2]  I. Smith,et al.  Choosing a negative pressure ventilation pump: are there any important differences? , 1995, The European respiratory journal.

[3]  I. Smith,et al.  A progressive care programme for prolonged ventilatory failure: analysis of outcome. , 1995, British journal of anaesthesia.

[4]  J. Bach,et al.  Sleep fragmentation in kyphoscoliotic individuals with alveolar hypoventilation treated by NIPPV. , 1995, Chest.

[5]  J. Guttmann,et al.  An analysis of desynchronization between the spontaneously breathing patient and ventilator during inspiratory pressure support. , 1995, Chest.

[6]  M. Vitacca,et al.  Different modes of noninvasive intermittent positive pressure ventilation (IPPV) in acute exacerbations of COLD patients. , 1994, Monaldi archives for chest disease = Archivio Monaldi per le malattie del torace.

[7]  I. Smith,et al.  Long term non-invasive domiciliary assisted ventilation for respiratory failure following thoracoplasty. , 1994, Thorax.

[8]  S. Nardini Noninvasive mechanical ventilation in acute respiratory failure. , 1994, Monaldi archives for chest disease = Archivio Monaldi per le malattie del torace.

[9]  A. Simonds,et al.  A comparison of different modes of noninvasive ventilatory support: effects on ventilation and inspiratory muscle effort , 1994, Anaesthesia.

[10]  J. Wedzicha,et al.  Comparison of pressure and volume preset nasal ventilator systems in stable chronic respiratory failure. , 1993, The European respiratory journal.

[11]  D. G. Schroeder,et al.  Pneumothorax complicating BiPAP therapy for Pneumocystis carinii pneumonia. , 1993, Chest.

[12]  J. Wedzicha,et al.  Comparison of nasal pressure support ventilation with nasal intermittent positive pressure ventilation in patients with nocturnal hypoventilation. , 1993, The European respiratory journal.

[13]  A. Simonds,et al.  Nasal ventilation to facilitate weaning in patients with chronic respiratory insufficiency. , 1992, Thorax.

[14]  A. Simonds,et al.  Domiciliary nocturnal nasal intermittent positive pressure ventilation in hypercapnic respiratory failure due to chronic obstructive lung disease: effects on sleep and quality of life. , 1992, Thorax.

[15]  D. Rodenstein,et al.  Upper airway obstruction during nasal intermittent positive-pressure hyperventilation in sleep , 1991, The Lancet.

[16]  M. Sanders,et al.  Obstructive sleep apnea treated by independently adjusted inspiratory and expiratory positive airway pressures via nasal mask. Physiologic and clinical implications. , 1990, Chest.

[17]  M. Elliott,et al.  Non-invasive mechanical ventilation for acute respiratory failure. , 1990, BMJ.

[18]  C. Sullivan,et al.  Noninvasive ventilatory support during sleep improves respiratory failure in kyphoscoliosis. , 1988, Chest.

[19]  J. Polu,et al.  Nasal intermittent positive pressure ventilation. Long-term follow-up in patients with severe chronic respiratory insufficiency. , 1994, Chest.

[20]  M. Younes Proportional Assist Ventilation and Pressure Support Ventilation: Similarities and Differences , 1991 .

[21]  J. Bach,et al.  Management of chronic alveolar hypoventilation by nasal ventilation. , 1990, Chest.