Use of Ventricular Assist Device in Univentricular Physiology: The Role of Lumped Parameter Models.

Failing single-ventricle (SV) patients might benefit from ventricular assist devices (VADs) as a bridge to heart transplantation. Considering the complex physiopathology of SV patients and the lack of established experience, the aim of this work was to realize and test a lumped parameter model of the cardiovascular system, able to simulate SV hemodynamics and VAD implantation effects. Data of 30 SV patients (10 Norwood, 10 Glenn, and 10 Fontan) were retrospectively collected and used to simulate patients' baseline. Then, the effects of VAD implantation were simulated. Additionally, both the effects of ventricular assistance and cavopulmonary assistance were simulated in different pathologic conditions on Fontan patients, including systolic dysfunction, diastolic dysfunction, and pulmonary vascular resistance increment. The model can reproduce patients' baseline well. Simulation results suggest that the implantation of VAD: (i) increases the cardiac output (CO) in all the three palliation conditions (Norwood 77.2%, Glenn 38.6%, and Fontan 17.2%); (ii) decreases the SV external work (SVEW) (Norwood 55%, Glenn 35.6%, and Fontan 41%); (iii) increases the mean pulmonary arterial pressure (Pap) (Norwood 39.7%, Glenn 12.1%, and Fontan 3%). In Fontan circulation, with systolic dysfunction, the left VAD (LVAD) increases CO (35%), while the right VAD (RVAD) determines a decrement of inferior vena cava pressure (Pvci) (39%) with 34% increment of CO. With diastolic dysfunction, the LVAD increases CO (42%) and the RVAD decreases the Pvci. With pulmonary vascular resistance increment, the RVAD allows the highest CO (50%) increment with the highest decrement of Pvci (53%). The single ventricular external work (SVEW) increases (decreases) increasing the VAD speed in cavopulmonary (ventricular) assistance. Numeric models could be helpful in this challenging and innovative field to support patients and VAD selection to optimize the clinical outcome and personalize the therapy.

[1]  G. Carman,et al.  In vitro evaluation of an external compression device for fontan mechanical assistance. , 2014, Artificial organs.

[2]  J. Tobias,et al.  Use of a ventricular assist device as a bridge to transplantation in a patient with single ventricle physiology and total cavopulmonary anastomosis , 2008, Paediatric anaesthesia.

[3]  B. Griffith,et al.  Pre-clinical evaluation of the infant Jarvik 2000 heart in a neonate piglet model. , 2013, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[4]  A. Amodeo,et al.  Ventricular assist device in univentricular heart physiology. , 2013, Interactive cardiovascular and thoracic surgery.

[5]  D. Ross,et al.  The use of ventricular assist devices in pediatric patients with univentricular hearts. , 2011, The Journal of thoracic and cardiovascular surgery.

[6]  Sarah Furness,et al.  The Berlin Heart EXCOR Pediatrics-The SickKids Experience 2004-2008. , 2010, Artificial organs.

[7]  D. Farrar,et al.  Application of Computer Modeling in Systemic VAD Support of Failing Fontan Physiology , 2011, World journal for pediatric & congenital heart surgery.

[8]  Patricia Friedmann,et al.  The use of the Berlin Heart EXCOR in patients with functional single ventricle. , 2014, The Journal of thoracic and cardiovascular surgery.

[9]  M. Trivella,et al.  Simulation of Ventricular, Cavo-Pulmonary, and Biventricular Ventricular Assist Devices in Failing Fontan. , 2015, Artificial organs.

[10]  K. Sharma,et al.  Berlin Heart ventricular assist device in a child with hypoplastic left heart syndrome. , 2007, The Annals of thoracic surgery.

[11]  Robert H. Bartlett,et al.  Berlin Heart EXCOR Pediatric ventricular assist device Investigational Device Exemption study: study design and rationale. , 2011, American heart journal.

[12]  Gianfranco Ferrari,et al.  Simulation of Apical and Atrio-aortic VAD in Patients with Transposition or Congenitally Corrected Transposition of the Great Arteries , 2014, The International journal of artificial organs.

[13]  J. Rychik,et al.  Mechanical support as failure intervention in patients with cavopulmonary shunts (MFICS): rationale and aims of a new registry of mechanical circulatory support in single ventricle patients. , 2013, Congenital heart disease.

[14]  Amy L Throckmorton,et al.  Mechanical cavopulmonary assistance of a patient-specific Fontan physiology: numerical simulations, lumped parameter modeling, and suction experiments. , 2011, Artificial organs.

[15]  Gianfranco Ferrari,et al.  Hemodynamic Effects of Ventricular Assist Device Implantation on Norwood, Glenn, and Fontan Circulation: A Simulation Study. , 2016, Artificial organs.

[16]  Mahesh Sharma,et al.  Management of single-ventricle patients with Berlin Heart EXCOR Ventricular Assist Device: single-center experience. , 2012, Artificial organs.

[17]  J. Zwischenberger,et al.  A paired membrane umbrella double-lumen cannula ensures consistent cavopulmonary assistance in a Fontan sheep model. , 2014, The Journal of thoracic and cardiovascular surgery.

[18]  F. Migliavacca,et al.  Computational model of the fluid dynamics in systemic-to-pulmonary shunts. , 2000, Journal of biomechanics.

[19]  Jun Chen,et al.  Cavopulmonary Assist for the Failing Fontan Circulation: Impact of Ventricular Function on Mechanical Support Strategy , 2014, ASAIO journal.

[20]  M. Nathan,et al.  Successful implantation of a Berlin heart biventricular assist device in a failing single ventricle. , 2006, The Journal of thoracic and cardiovascular surgery.

[21]  A. Yoganathan,et al.  Coupling Pediatric Ventricle Assist Devices to the Fontan Circulation: Simulations with a Lumped-Parameter Model , 2005, ASAIO journal.

[22]  J. Forbess,et al.  Ventricular assist device support in children and adolescents with heart failure: the Children's Medical Center of Dallas experience. , 2012, Artificial organs.

[23]  Amy L Throckmorton,et al.  Dual-pump support in the inferior and superior vena cavae of a patient-specific fontan physiology. , 2013, Artificial organs.

[24]  C. VanderPluym,et al.  Advanced therapies for congenital heart disease: ventricular assist devices and heart transplantation. , 2013, The Canadian journal of cardiology.

[25]  C. Brizard,et al.  Successful left ventricular assist device bridge to transplantation after failure of a fontan revision. , 2006, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.