Interlaboratory Test of Exhaust PM Using ELPI

Abstract The Particulate Measurement Programme (PMP) works on the development of an improved method for the exhaust particulate matter (PM) measurement, which can include, if feasible and necessary, the measurement of particle number. The French PMP subgroup, composed of IFP, PSA Peugeot-Citroën, Renault, and UTAC, has defined a measurement protocol based on electrical low-pressure impactor (ELPI) and conducted an interlaboratory test to evaluate its performances. The technical program was based on tests carried out on three Euro3 passenger cars (one gasoline operating under stoichiometric conditions, one Diesel, and one Diesel equipped with a diesel particulate filter (DPF)) that were tested on the New European Driving Cycle (NEDC). The regulated pollutants are also measured, as indicators of test repeatability and good working conditions. The interlaboratory reproducibility value of the tunnel background tests is quite high (337%) due to low particle numbers. The repeatability values increase at low particle numbers independently of the vehicle used. On the NEDC, the reproducibility of total particle number is 59, 47, and 131% for the gasoline, Diesel, and DPF-equipped Diesel vehicles, respectively (compare to 67, 29, and 164% for PM collected on filters). These results show that the protocol used in this study allows a reliable measurement of exhaust particle number in the case of vehicles emitting at least two orders of magnitude more than the tunnel background. In the other cases, the measurement variability is too high, especially for regulatory purposes, without taking into account other metrological aspects, such as calibration.

[1]  Richard C. Flagan,et al.  Scanning Electrical Mobility Spectrometer , 1989 .

[2]  Jorma Keskinen,et al.  Electrical low pressure impactor , 1992 .

[3]  CRC Speciated Hydrocarbon Emissions Analysis Round Robin Test Program , 1995 .

[4]  Silvestre B. Tejada,et al.  CRC Carbonyl Emissions Analysis Round Robin Program - Phase II , 1997 .

[5]  S. Krantz,et al.  Diesel Engine Development is Guided by Inadequate Particle Sampling , 1997 .

[6]  W. Biller,et al.  CRC HYDROCARBON EMISSIONS ANALYSIS ROUND ROBIN TEST PROGRAM, PHASE II , 1997 .

[7]  Leonidas Ntziachristos,et al.  Real Time Measurements of Diesel Particle Size Distribution with an Electrical Low Pressure Impactor , 1998 .

[8]  L. Ntziachristos,et al.  Effect of DPF on Particulate Size Distribution Using an Electrical Low Pressure Impactor , 1998 .

[9]  H. Lüders,et al.  The Role of Sampling Conditions in Particle Size Distribution Measurements , 1998 .

[10]  M. Maricq,et al.  Vehicle Exhaust Particle Size Distributions: A Comparison of Tailpipe and Dilution Tunnel Measurements , 1999 .

[11]  D. Kittelson,et al.  The influence of dilution conditions on diesel exhaust particle size distribution measurements , 1999 .

[12]  U. Matter,et al.  DYNAMIC FIELD MEASUREMENTS OF SUBMICRON PARTICLES FROM DIESEL ENGINES , 1999 .

[13]  R. Harrison,et al.  Particle size distribution from a modern heavy duty diesel engine , 1999 .

[14]  Jorma Keskinen,et al.  PERFORMANCE EVALUATION OF THE ELECTRICAL LOW-PRESSURE IMPACTOR (ELPI) , 2000 .

[15]  Imad A. Khalek Characterization of Particle Size Distribution of a Heavy-Duty Diesel Engine During FTP Transient Cycle Using ELPI , 2000 .

[16]  Leonidas Ntziachristos,et al.  Sampling Conditions Effects on Real-Time Particle Measurements from a Light Duty Vehicle , 2000 .

[17]  Richard E. Chase,et al.  Size Distributions of Motor Vehicle Exhaust PM: A Comparison Between ELPI and SMPS Measurements , 2000 .

[18]  Gordon E. Andrews,et al.  Diesel Particle Size Distribution Changes Along a Practical Exhaust System During Cold Start in a Passenger Car IDI Diesel , 2000 .

[19]  Y. Goto,et al.  Continuous Measurement of Diesel Particulate Emissions by an Electrical Low-Pressure Impactor , 2000 .

[20]  Jacob A. Moulijn,et al.  Restriction for the ELPI in diesel particulate measurements , 2001 .

[21]  G. Andrews,et al.  Diesel Particle Size Distribution: The Conversion Of Particle Number Size Distribution To Mass Distribution , 2001 .

[22]  B. Wehner,et al.  Design and calibration of a thermodenuder with an improved heating unit to measure the size-dependent volatile fraction of aerosol particles , 2002 .

[23]  Jorma Keskinen,et al.  Effective Density of Diesel Exhaust Particles as a Function of Size , 2002 .

[24]  Jorma Keskinen,et al.  On-line measurement of size distribution and effective density of submicron aerosol particles , 2002 .

[25]  ELPI Measurement of Particulate Matter from HSDI Diesel Engine with Diesel Oxidation Catalyst , 2003 .

[26]  Martin Mohr,et al.  Part 2: Effect of sampling conditions and fuel sulphur content on the particle emission , 2003 .

[27]  J. Moulijn,et al.  The Choice of Instrument (ELPI and/or SMPS) for Diesel Soot Particulate Measurements , 2003 .

[28]  E. Zervas,et al.  Repeatability of Fine Particle Measurement of Diesel and Gasoline Vehicles Exhaust Gas , 2004 .

[29]  Richard E. Chase,et al.  Time-Resolved Measurements of Exhaust PM for FTP-75:Comparison of LII, ELPI, and TEOM Techniques , 2004 .

[30]  Jacob A. Moulijn,et al.  Measuring diesel soot with a scanning mobility particle sizer and an electrical low-pressure impactor: Performance assessment with a model for fractal-like agglomerates , 2004 .

[31]  M. Maricq,et al.  The effective density and fractal dimension of soot particles from premixed flames and motor vehicle exhaust , 2004 .

[32]  Georges R. Fournier,et al.  The particle size distribution , 2007 .