Conducting accelerometer-based activity assessments in field-based research.

PURPOSE The purpose of this review is to address important methodological issues related to conducting accelerometer-based assessments of physical activity in free-living individuals. METHODS We review the extant scientific literature for empirical information related to the following issues: product selection, number of accelerometers needed, placement of accelerometers, epoch length, and days of monitoring required to estimate habitual physical activity. We also discuss the various options related to distributing and collecting monitors and strategies to enhance compliance with the monitoring protocol. RESULTS No definitive evidence exists currently to indicate that one make and model of accelerometer is more valid and reliable than another. Selection of accelerometer therefore remains primarily an issue of practicality, technical support, and comparability with other studies. Studies employing multiple accelerometers to estimate energy expenditure report only marginal improvements in explanatory power. Accelerometers are best placed on hip or the lower back. Although the issue of epoch length has not been studied in adults, the use of count cut points based on 1-min time intervals maybe inappropriate in children and may result in underestimation of physical activity. Among adults, 3-5 d of monitoring is required to reliably estimate habitual physical activity. Among children and adolescents, the number of monitoring days required ranges from 4 to 9 d, making it difficult to draw a definitive conclusion for this population. Face-to-face distribution and collection of accelerometers is probably the best option in field-based research, but delivery and return by express carrier or registered mail is a viable option. CONCLUSION Accelerometer-based activity assessments requires careful planning and the use of appropriate strategies to increase compliance.

[1]  Diane J Catellier,et al.  School-level intraclass correlation for physical activity in adolescent girls. , 2004, Medicine and science in sports and exercise.

[2]  C. Pieper,et al.  The reliability, validity, and stability of a measure of physical activity in the elderly. , 1996, Archives of physical medicine and rehabilitation.

[3]  J. D. Janssen,et al.  Assessment of energy expenditure for physical activity using a triaxial accelerometer. , 1994, Medicine and science in sports and exercise.

[4]  Issa Zakeri,et al.  Prediction of activity energy expenditure using accelerometers in children. , 2004, Medicine and science in sports and exercise.

[5]  J. Witt,et al.  The stability of children's physical activity as measured by accelerometry and self-report. , 1995, Medicine and science in sports and exercise.

[6]  P S Freedson,et al.  Calibration of the Computer Science and Applications, Inc. accelerometer. , 1998, Medicine and science in sports and exercise.

[7]  P. Freedson,et al.  Using objective physical activity measures with youth: how many days of monitoring are needed? , 2000, Medicine and science in sports and exercise.

[8]  J. Curnow,et al.  Technical reliability of the CSA activity monitor: The EarlyBird Study. , 2002, Medicine and science in sports and exercise.

[9]  Dewi I. Jones,et al.  Technical variability of the RT3 accelerometer. , 2003, Medicine and science in sports and exercise.

[10]  S. Brage,et al.  Reliability and Validity of the Computer Science and Applications Accelerometer in a Mechanical Setting , 2003 .

[11]  Scott E Crouter,et al.  Accuracy and reliability of 10 pedometers for measuring steps over a 400-m walk. , 2003, Medicine and science in sports and exercise.

[12]  Charles B. Corbin,et al.  Measurement Issues in the Assessment of Physical Activity in Children , 2000, Research quarterly for exercise and sport.

[13]  H. Nagaraja,et al.  Comparisons of four methods of estimating physical activity in adult women. , 2000, Medicine and science in sports and exercise.

[14]  P. Freedson,et al.  Validity of accelerometry for the assessment of moderate intensity physical activity in the field. , 2000, Medicine and science in sports and exercise.

[15]  S. Grant,et al.  Using the Computer Science and Applications (CSA) Activity Monitor in Preschool Children , 1999 .

[16]  Kuan Zhang,et al.  Measurement of human daily physical activity. , 2003, Obesity research.

[17]  B. Ainsworth,et al.  Estimation of energy expenditure using CSA accelerometers at hip and wrist sites. , 2000, Medicine and science in sports and exercise.

[18]  KR Westerterp,et al.  Physical activity assessment with accelerometers , 1999, International Journal of Obesity.

[19]  Scott E Crouter,et al.  Validity of 10 electronic pedometers for measuring steps, distance, and energy cost. , 2003, Medicine and science in sports and exercise.

[20]  J F Nichols,et al.  Validity, reliability, and calibration of the Tritrac accelerometer as a measure of physical activity. , 1999, Medicine and science in sports and exercise.

[21]  U. Ekelund,et al.  Assessing Physical Activity Among Children With Accelerometers Using Different Time Sampling Intervals and Placements , 2002 .

[22]  James Y. Paton,et al.  Comparison of Two Accelerometers for Assessment of Physical Activity in Preschool Children , 2004 .

[23]  H J Montoye,et al.  Variability of some objective measures of physical activity. , 1992, Medicine and science in sports and exercise.

[24]  P. Freedson,et al.  Validity of the Computer Science and Applications, Inc. (CSA) activity monitor. , 1995, Medicine and science in sports and exercise.

[25]  Gregory J Welk,et al.  Laboratory calibration and validation of the Biotrainer and Actitrac activity monitors. , 2003, Medicine and science in sports and exercise.

[26]  M. Verduin,et al.  Effects of placement and orientation of body-fixed accelerometers on the assessment of energy expenditure during walking , 2006, Medical and Biological Engineering and Computing.

[27]  Ann V Rowlands,et al.  Intermonitor variability of the RT3 accelerometer during typical physical activities. , 2004, Medicine and science in sports and exercise.

[28]  Barbara E. Ainsworth,et al.  Intra-individual variation and estimates of usual physical activity , 1999 .

[29]  David R Bassett,et al.  Sources of variance in daily physical activity levels as measured by an accelerometer. , 2002, Medicine and science in sports and exercise.

[30]  M. Puyau,et al.  Validation and calibration of physical activity monitors in children. , 2002, Obesity research.

[31]  S. Blair,et al.  A comparative evaluation of three accelerometry-based physical activity monitors. , 2000, Medicine and science in sports and exercise.

[32]  R. Eston,et al.  Validity of heart rate, pedometry, and accelerometry for predicting the energy cost of children's activities. , 1998, Journal of applied physiology.

[33]  Stewart G. Trost,et al.  The Use of Uniaxial and Triaxial Accelerometers to Measure Children’s “Free-Play” Physical Activity , 2000 .

[34]  C B Corbin,et al.  The validity of the Tritrac-R3D Activity Monitor for the assessment of physical activity in children. , 1995, Research quarterly for exercise and sport.

[35]  P. D. Watson,et al.  Validity of the computer science and applications (CSA) activity monitor in children. , 1998, Medicine and science in sports and exercise.

[36]  S G Trost,et al.  Objective Measurement of Physical Activity in Youth: Current Issues, Future Directions , 2001, Exercise and sport sciences reviews.

[37]  G. Welk,et al.  Reliability of accelerometry-based activity monitors: a generalizability study. , 2004, Medicine and science in sports and exercise.

[38]  D. Jacobs,et al.  Validity and reliability of activity measures in African-American girls for GEMS. , 2003, Medicine and science in sports and exercise.

[39]  L. Epstein,et al.  Application of generalizability theory to measurement of activity in males who are not regularly active: a preliminary report. , 1998, Research quarterly for exercise and sport.

[40]  P S Freedson,et al.  Objective Monitoring of Physical Activity Using Motion Sensors and Heart Rate , 2000, Research quarterly for exercise and sport.

[41]  L. Epstein,et al.  Relationships between TriTrac-R3D vectors, heart rate, and self-report in obese children. , 1997, Medicine and science in sports and exercise.

[42]  Ulf Ekelund,et al.  Effect of monitor placement and of activity setting on the MTI accelerometer output. , 2003, Medicine and science in sports and exercise.

[43]  H. Nagaraja,et al.  Evaluation of methods to assess physical activity in free-living conditions. , 2001, Medicine and science in sports and exercise.

[44]  L. Mâsse,et al.  Detecting bouts of physical activity in a field setting. , 1999, Research quarterly for exercise and sport.