The influence of electrospun scaffold topography on endothelial cell morphology, alignment, and adhesion in response to fluid flow

Bioengineered vascular grafts provide a promising alternative to autografts for replacing diseased or damaged arteries, but necessitate scaffold designs capable of supporting a confluent endothelium that resists endothelial cell (EC) detachment under fluid flow. To this end, we investigated whether tuning electrospun topography (i.e., fiber diameter and orientation) could impact EC morphology, alignment, and structural protein organization with the goal of forming a confluent and well‐adhered endothelium under fluid flow. To test this, a composite polymer blend of poly(ϵ‐caprolactone) (PCL) and type I collagen was electrospun to form scaffolds with controlled fiber diameters ranging from approximately 100–1,200 nm and with varying degrees of fiber alignment. ECs were seeded onto scaffolds, and cell morphology and degree of alignment were quantified using image analysis of fluorescently stained cells. Our results show that ECs form confluent monolayers on electrospun scaffolds, with cell alignment systematically increasing with a larger degree of fiber orientation. Additionally, cells on aligned electrospun scaffolds display thick F‐actin bundles parallel to the direction of fiber alignment and strong VE‐cadherin expression at cell–cell junctions. Under fluid flow, ECs on highly aligned scaffolds had greater resistance to detachment compared to cells cultured on randomly oriented and semi‐aligned scaffolds. These results indicate that scaffolds with aligned topographies may be useful in forming a confluent endothelium with enhanced EC adhesion for vascular tissue engineering applications. Biotechnol. Bioeng. 2014;111: 184–195. © 2013 Wiley Periodicals, Inc.

[1]  G. E. Green,et al.  Coronary bypass surgery with internal-thoracic-artery grafts--effects on survival over a 15-year period. , 1996, The New England journal of medicine.

[2]  Anthony Atala,et al.  The in vivo stability of electrospun polycaprolactone-collagen scaffolds in vascular reconstruction. , 2009, Biomaterials.

[3]  R. Lal,et al.  Shear stress-induced reorganization of the surface topography of living endothelial cells imaged by atomic force microscopy. , 1994, Circulation research.

[4]  J. Vita,et al.  Shear-stress-mediated arterial remodeling in atherosclerosis: too much of a good thing? , 2006, Circulation.

[5]  J. Lannutti,et al.  Electrospun scaffold topography affects endothelial cell proliferation, metabolic activity, and morphology. , 2010, Journal of biomedical materials research. Part A.

[6]  J. Loscalzo,et al.  Endothelial cells in physiology and in the pathophysiology of vascular disorders. , 1998, Blood.

[7]  Anthony Atala,et al.  Functional small-diameter neovessels created using endothelial progenitor cells expanded ex vivo , 2001, Nature Medicine.

[8]  T. McAllister,et al.  Tissue-engineered blood vessel for adult arterial revascularization. , 2007, The New England journal of medicine.

[9]  M S Conte,et al.  The ideal small arterial substitute: a search for the Holy Grail? , 1998, FASEB journal : official publication of the Federation of American Societies for Experimental Biology.

[10]  Yong Woo Lee,et al.  Effect of intermittent shear stress on mechanotransductive signaling and osteoblastic differentiation of bone marrow stromal cells. , 2008, Tissue engineering. Part A.

[11]  R. Composto,et al.  Topographic guidance of endothelial cells on silicone surfaces with micro- to nanogrooves: orientation of actin filaments and focal adhesions. , 2005, Journal of biomedical materials research. Part A.

[12]  W. Pearce,et al.  Endothelial cell function: biologic and physiologic functions in health and disease. , 1996, AJR. American journal of roentgenology.

[13]  Alexander M Seifalian,et al.  Shear‐stress preconditioning and tissue‐engineering‐based paradigms for generating arterial substitutes , 2004, Biotechnology and applied biochemistry.

[14]  Anthony Atala,et al.  Development of a composite vascular scaffolding system that withstands physiological vascular conditions. , 2008, Biomaterials.

[15]  James J. Yoo,et al.  Bilayered scaffold for engineering cellularized blood vessels. , 2010, Biomaterials.

[16]  Hongjun Song,et al.  The effect of nano fi ber-guided cell alignment on the preferential differentiation of neural stem cells , 2022 .

[17]  S. Yazdani,et al.  The fate of an endothelium layer after preconditioning. , 2010, Journal of vascular surgery.

[18]  Christopher J Murphy,et al.  Modulation of human vascular endothelial cell behaviors by nanotopographic cues. , 2010, Biomaterials.

[19]  Hai-Quan Mao,et al.  The effect of nanofiber-guided cell alignment on the preferential differentiation of neural stem cells. , 2010, Biomaterials.

[20]  George M. Whitesides,et al.  Controlling Mammalian Cell Spreading and Cytoskeletal Arrangement with Conveniently Fabricated Continuous Wavy Features on Poly(dimethylsiloxane) , 2002 .

[21]  A. Mikos,et al.  Electrospun poly(epsilon-caprolactone) microfiber and multilayer nanofiber/microfiber scaffolds: characterization of scaffolds and measurement of cellular infiltration. , 2006, Biomacromolecules.

[22]  Takehisa Matsuda,et al.  The effect of gradually graded shear stress on the morphological integrity of a huvec-seeded compliant small-diameter vascular graft. , 2007, Biomaterials.

[23]  C. Bashur,et al.  Effect of fiber diameter and orientation on fibroblast morphology and proliferation on electrospun poly(D,L-lactic-co-glycolic acid) meshes. , 2006, Biomaterials.

[24]  P. Davies,et al.  Flow-mediated endothelial mechanotransduction. , 1995, Physiological reviews.

[25]  Zi Yin,et al.  The regulation of tendon stem cell differentiation by the alignment of nanofibers. , 2010, Biomaterials.

[26]  N. L'Heureux,et al.  Human tissue-engineered blood vessels for adult arterial revascularization , 2007, Nature Medicine.

[27]  Laura E Niklason,et al.  Decellularized tissue-engineered blood vessel as an arterial conduit , 2011, Proceedings of the National Academy of Sciences.

[28]  Christoph Ballestrem,et al.  Vinculin controls focal adhesion formation by direct interactions with talin and actin , 2007, The Journal of cell biology.

[29]  R. Black,et al.  PCL-PU composite vascular scaffold production for vascular tissue engineering: attachment, proliferation and bioactivity of human vascular endothelial cells. , 2006, Biomaterials.

[30]  B L Langille,et al.  Dynamics of shear-induced redistribution of F-actin in endothelial cells in vivo. , 1991, Arteriosclerosis and thrombosis : a journal of vascular biology.

[31]  Anthony Atala,et al.  In vitro evaluation of electrospun nanofiber scaffolds for vascular graft application. , 2007, Journal of biomedical materials research. Part A.

[32]  B. Helmke,et al.  Mapping the dynamics of shear stress-induced structural changes in endothelial cells. , 2007, American journal of physiology. Cell physiology.

[33]  K J Gooch,et al.  Improved microvascular network in vitro by human blood outgrowth endothelial cells relative to vessel-derived endothelial cells. , 2005, Tissue engineering.

[34]  Alexander M Seifalian,et al.  Improving the clinical patency of prosthetic vascular and coronary bypass grafts: the role of seeding and tissue engineering. , 2002, Artificial organs.

[35]  William C. Aird,et al.  Phenotypic Heterogeneity of the Endothelium: I. Structure, Function, and Mechanisms , 2007, Circulation research.

[36]  C J Murphy,et al.  Effects of synthetic micro- and nano-structured surfaces on cell behavior. , 1999, Biomaterials.

[37]  W. Aird Phenotypic Heterogeneity of the Endothelium: II. Representative Vascular Beds , 2007, Circulation research.

[38]  D. Vorp,et al.  Development of a tissue-engineered vascular graft combining a biodegradable scaffold, muscle-derived stem cells and a rotational vacuum seeding technique. , 2008, Biomaterials.

[39]  George J Christ,et al.  The influence of electrospun aligned poly(epsilon-caprolactone)/collagen nanofiber meshes on the formation of self-aligned skeletal muscle myotubes. , 2008, Biomaterials.

[40]  B. Ballermann,et al.  Chronic in vitro shear stress stimulates endothelial cell retention on prosthetic vascular grafts and reduces subsequent in vivo neointimal thickness. , 1999, Journal of vascular surgery.

[41]  R. Guignard,et al.  Isolation and culture of the three vascular cell types from a small vein biopsy sample , 2003, In Vitro Cellular & Developmental Biology - Animal.

[42]  Chrysanthi Williams,et al.  Perfusion bioreactor for small diameter tissue-engineered arteries. , 2004, Tissue engineering.

[43]  R Langer,et al.  Functional arteries grown in vitro. , 1999, Science.

[44]  J. Lannutti,et al.  Interactions between endothelial cells and electrospun methacrylic terpolymer fibers for engineered vascular replacements. , 2009, Journal of biomedical materials research. Part A.

[45]  Robert J Levy,et al.  Micropatterning of three-dimensional electrospun polyurethane vascular grafts. , 2010, Acta biomaterialia.