Extraction of Phase Information from Magnitude-Only Bio-impedance Measurements Using a Modified Kramers–Kronig Transform

The need for portable and low-cost bio-impedance analyzers that can be deployed in field studies has significantly increased. Due to size and power constraints, reducing the hardware in these devices is crucial and most importantly is removing the need for direct phase measurement. In this paper a new magnitude-only technique based on modified Kramers–Kronig transforms is proposed and tested. Comparison with impedance measurements of fresh and aging tomato samples using a precise industry standard impedance analyzer is carried out and explained. Error and noise analysis of the proposed algorithm are also reported.

[1]  Digby D. Macdonald,et al.  Application of Kramers‐Kronig Transforms in the Analysis of Electrochemical Systems I . Polarization Resistance , 1985 .

[2]  Samsuzana Abd Aziz,et al.  Impedance analysis of Labisia pumila plant water status , 2015 .

[3]  P. Grosse,et al.  Analysis of reflectance data using the Kramers-Kronig Relations , 1991 .

[4]  Vinay Kumar,et al.  Maturity and disease detection in tomato using computer vision , 2016, 2016 Fourth International Conference on Parallel, Distributed and Grid Computing (PDGC).

[5]  Jerzy Hoja,et al.  A family of new generation miniaturized impedance analyzers for technical object diagnostics , 2013 .

[6]  Tomasz Piasecki,et al.  Simple Wide Frequency Range Impedance Meter Based on AD5933 Integrated Circuit , 2015 .

[7]  H. W. Bode Relations between attenuation and phase in feedback amplifier design , 1940 .

[8]  Digby D. Macdonald,et al.  Applications of Kramers—Kronig transforms in the analysis of electrochemical impedance data—III. Stability and linearity , 1990 .

[9]  R. Kronig On the Theory of Dispersion of X-Rays , 1926 .

[10]  Florian Mansfeld,et al.  Concerning the use of the Kramers-Kronig transforms for the validation of impedance data , 1988 .

[11]  T. Pritz,et al.  Unbounded complex modulus of viscoelastic materials and the Kramers-Kronig relations , 2005 .

[12]  Congo Tak-Shing Ching,et al.  Design and evaluation of an affordable and programmable mobile device, capable of delivering constant current and high voltage electric pulses of different waveforms for biomedical and clinical applications , 2014 .

[13]  A. S. Bondarenko,et al.  Potentiodynamic Electrochemical Impedance Spectroscopy , 2004 .

[14]  Andreas Demosthenous,et al.  Wideband Fully-Programmable Dual-Mode CMOS Analogue Front-End for Electrical Impedance Spectroscopy , 2016, Sensors.

[15]  Stanislava Papezova,et al.  Signal processing of bioimpedance equipment , 2003 .

[16]  Digby D. Macdonald,et al.  Application of Kramers‐Kronig Transforms in the Analysis of Electrochemical Impedance Data II . Transformations in the Complex Plane , 1986 .

[17]  Vairis Shtrauss,et al.  FIR Kramers-Kronig transformers for relaxation data conversion , 2006, Signal Process..

[18]  Hyo il Jung,et al.  An impedimetric biosensor for real-time monitoring of bacterial growth in a microbial fermentor , 2009 .

[19]  Cristian-Gyozo Haba,et al.  Wearable impedance analyzer based on AD5933 , 2014, 2014 International Conference and Exposition on Electrical and Power Engineering (EPE).

[20]  H. W. Bode,et al.  Network analysis and feedback amplifier design , 1945 .

[21]  Ahmed S. Elwakil,et al.  Design of a Portable Low-Cost Impedance Analyzer , 2017, BIODEVICES.

[22]  Ahmed S. Elwakil,et al.  Extracting the parameters of the double-dispersion Cole bioimpedance model from magnitude response measurements , 2014, Medical & Biological Engineering & Computing.

[23]  Ahmed S. Elwakil,et al.  Extracting the parameters of the single-dispersion Cole bioimpedance model using a magnitude-only method , 2015, Comput. Electron. Agric..

[24]  Mitar Simic,et al.  Realization of Complex Impedance Measurement System Based on the Integrated Circuit AD5933 , 2013, 2013 21st Telecommunications Forum Telfor (TELFOR).

[25]  Kang-Ming Chang,et al.  A circuit design of a low-cost, portable and programmable electroporation device for biomedical applications , 2012 .

[26]  S. Hahn Hilbert Transforms in Signal Processing , 1996 .

[27]  Tomasz Piasecki,et al.  Design, calibration and tests of versatile low frequency impedance analyser based on ARM microcontroller , 2016 .

[28]  Mark E. Orazem,et al.  On the Application of the Kramers‐Kronig Relations to Evaluate the Consistency of Electrochemical Impedance Data , 1991 .

[29]  Pedro M. Ramos,et al.  Comparison of impedance measurements in a DSP using ellipse-fit and seven-parameter sine-fit algorithms , 2009 .

[30]  P.M. Ramos,et al.  Implementation of DSP based Algorithms for Impedance Measurements , 2007, 2007 IEEE International Conference on Signal Processing and Communications.

[31]  A. Cruz Serra,et al.  Impedance Measurement With Sine-Fitting Algorithms Implemented in a DSP Portable Device , 2008, IEEE Transactions on Instrumentation and Measurement.

[32]  Carlos León,et al.  Use of Kramers–Kronig transforms for the treatment of admittance spectroscopy data of p‐n junctions containing traps , 1996 .

[33]  A. Cruz Serra,et al.  DSP Based Portable Impedance Measurement Instrument Using Sine-Fitting Algorithms , 2005, 2005 IEEE Instrumentationand Measurement Technology Conference Proceedings.

[34]  Fernando Seoane,et al.  Wearable Biomedical Measurement Systems for Assessment of Mental Stress of Combatants in Real Time , 2014, Sensors.