A uniaxial bioMEMS device for quantitative force-displacement measurements

There is a need for experimental techniques that allow the simultaneous imaging of cellular cystoskeletal components with quantitative force measurements on single cells. A bioMEMS device has been developed for the application of strain to a single cell while simultaneously quantifying its force response. The prototype device presented here allows the mechanical study of a single, adherent cell in vitro. The device works in a fashion similar to a displacement-controlled uniaxial tensile machine. The device is calibrated using an AFM cantilever and shows excellent agreement with the calculated spring constant. The device is demonstrated on a single fibroblast. The force response of the cell is seen to be linear until the onset of de-adhesion with the de-adhesion from the cell platform occurring at a force of approximately 1500 nN.

[1]  J. M. Fernández,et al.  Unfolding of titin domains explains the viscoelastic behavior of skeletal myofibrils. , 2001, Biophysical journal.

[2]  D. Ingber,et al.  Mechanotransduction across the cell surface and through the cytoskeleton , 1993 .

[3]  David F. Williams,et al.  Platelet reactions to modified surfaces under dynamic conditions , 1998, Journal of materials science. Materials in medicine.

[4]  A. D'Angelo,et al.  Fibronectin and laminin enhance gingival cell attachment to dental implant surfaces in vitro. , 1995, The International journal of oral & maxillofacial implants.

[5]  Jianxin Chen,et al.  Twisting integrin receptors increases endothelin-1 gene expression in endothelial cells. , 2001, American journal of physiology. Cell physiology.

[6]  Y. Missirlis,et al.  Assessment of techniques used in calculating cell-material interactions. , 2002, Biomolecular engineering.

[7]  Ben Fabry,et al.  Time scale and other invariants of integrative mechanical behavior in living cells. , 2003, Physical review. E, Statistical, nonlinear, and soft matter physics.

[8]  Marco Tortonese,et al.  Characterization of application-specific probes for SPMs , 1997, Photonics West.

[9]  A. J. Reid,et al.  Endothelial cell alignment on cyclically-stretched silicone surfaces , 2004, Journal of materials science. Materials in medicine.

[10]  D. Navajas,et al.  Scaling the microrheology of living cells. , 2001, Physical review letters.

[11]  O. Thoumine,et al.  Time scale dependent viscoelastic and contractile regimes in fibroblasts probed by microplate manipulation. , 1997, Journal of cell science.

[12]  H. Gaub,et al.  Adhesion forces between individual ligand-receptor pairs. , 1994, Science.

[13]  R M Hochmuth,et al.  Erythrocyte membrane elasticity and viscosity. , 1987, Annual review of physiology.

[14]  K. Zaner,et al.  Viscoelasticity of F-actin measured with magnetic microparticles , 1989, The Journal of cell biology.

[15]  Jennifer S. Park,et al.  Differential effects of equiaxial and uniaxial strain on mesenchymal stem cells , 2004, Biotechnology and bioengineering.

[16]  D E Ingber,et al.  Analysis of cell mechanics in single vinculin-deficient cells using a magnetic tweezer. , 2000, Biochemical and biophysical research communications.

[17]  K. Svoboda,et al.  Biological applications of optical forces. , 1994, Annual review of biophysics and biomolecular structure.

[18]  C. S. Chen,et al.  Demonstration of mechanical connections between integrins, cytoskeletal filaments, and nucleoplasm that stabilize nuclear structure. , 1997, Proceedings of the National Academy of Sciences of the United States of America.

[19]  A Guignandon,et al.  Physiological strains induce differentiation in human osteoblasts cultured on orthopaedic biomaterial. , 2003, Biomaterials.

[20]  Clifford Goodman,et al.  American Society of Mechanical Engineers , 1988 .

[21]  D E Ingber,et al.  Cellular control lies in the balance of forces. , 1998, Current opinion in cell biology.

[22]  Atsushi Ikai,et al.  Quantification of fibronectin and cell surface interactions by AFM , 2002 .

[23]  R. Skalak,et al.  Passive mechanical properties of human leukocytes. , 1981, Biophysical journal.

[24]  M. Saif,et al.  Functionalized Biomicroelectromechanical Systems Sensors for Force Response Study at Local Adhesion Sites of Single Living Cells on Substrates , 2003, Annals of Biomedical Engineering.

[25]  Y. Fung,et al.  Elementary mechanics of the endothelium of blood vessels. , 1993, Journal of biomechanical engineering.

[26]  M. Glogauer,et al.  Cell-substrate separation: effect of applied force and temperature , 1998, European Biophysics Journal.

[27]  P. Janmey The cytoskeleton and cell signaling: component localization and mechanical coupling. , 1998, Physiological reviews.

[28]  J. Simeon,et al.  Creep function of a single living cell. , 2005, Biophysical journal.

[29]  Deformability and viscoelasticity of human erythrocyte membrane. , 1981, Scandinavian journal of clinical and laboratory investigation. Supplementum.

[30]  R M Hochmuth,et al.  Membrane viscoelasticity. , 1976, Biophysical journal.

[31]  L. Claes,et al.  Effekte mechanischer Reize auf humane osteoblastäre Zellen in einer dreidimensionalen Kollagen-Typ-I-Matrix , 2004, Der Orthopäde.

[32]  A. Yamamoto,et al.  A new technique for direct measurement of the shear force necessary to detach a cell from a material. , 1998, Biomaterials.

[33]  Shengyuan Yang,et al.  Reversible and repeatable linear local cell force response under large stretches. , 2005, Experimental cell research.

[34]  E. Evans,et al.  Apparent viscosity and cortical tension of blood granulocytes determined by micropipet aspiration. , 1989, Biophysical journal.

[35]  W. Kraus,et al.  Endothelial, cardiac muscle and skeletal muscle exhibit different viscous and elastic properties as determined by atomic force microscopy. , 2001, Journal of biomechanics.

[36]  D. Wirtz,et al.  Mechanics of living cells measured by laser tracking microrheology. , 2000, Biophysical journal.