Improvements in optical generation of high-frequency ultrasound

The thermoelastic effect in a black poly-dimethylsiloxane (PDMS) film is used to produce high-frequency, high-intensity ultrasound for applications in water and soft tissue. We show that the optoacoustic transduction efficiency is improved by about 10 dB by decreasing the thickness of the black PDMS film from 25 mum to 11 mum. The center frequency of the generated ultrasound is 60 MHz, with a -6 dB bandwidth of 80%. When a 5 ns laser pulse with energy of 50 ns is delivered to a spot size of 25 mum, the acoustic pressure 10 mm away from the film surface is about 800 kPa. Furthermore, we demonstrate that the center frequency and bandwidth of the generated ultrasound is mainly determined by the temporal profile of the input optical pulse, and it has the potential to be easily improved to above 100 MHz

[1]  Timothy A. Ritter,et al.  High-frequency transducers for ultrasonic backscatter microscopy , 1999, Medical Imaging.

[2]  Ruibin Liu,et al.  Interdigital Pair Bonding for High Frequency , 2001 .

[3]  A high frequency ultrasound array element using thermoelastic expansion in PDMS , 2001, 2001 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.01CH37263).

[4]  M. O'Donnell,et al.  Thermoelastic expansion vs. piezoelectricity for high-frequency, 2-D arrays , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  Matthew O'Donnell,et al.  Optoacoustic imaging using thin polymer étalon , 2005 .

[6]  Chang-Hong Hu,et al.  High-frequency ultrasound annular-array imaging. Part I: array design and fabrication , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  J. E. Parsons,et al.  Cost-effective assembly of a basic fiber-optic hydrophone for measurement of high-amplitude therapeutic ultrasound fields. , 2006, The Journal of the Acoustical Society of America.

[8]  C. H. Skeen,et al.  Laser‐induced stress‐wave and impulse augmentation , 1972 .

[9]  Richard M. White,et al.  Generation of Elastic Waves by Transient Surface Heating , 1963 .

[10]  H. K. Wickramasinghe,et al.  A Fabry-Perot acoustic surface vibration detector - application to acoustic holography , 1973 .

[11]  K. Shung,et al.  A 30-MHz piezo-composite ultrasound array for medical imaging applications , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  M. O'Donnell,et al.  Synthetic phased arrays for intraluminal imaging of coronary arteries , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[13]  S.W. Smith,et al.  High-density flexible interconnect for two-dimensional ultrasound arrays , 2000, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  Matthew O'Donnell,et al.  High-frequency ultrasound array element using thermoelastic expansion in an elastomeric film , 2001 .

[15]  C. Grover Photothermal Generation of Thermoelastic Waves in Composite Media , 1986 .

[16]  M. O'Donnell,et al.  A high-frequency, 2-D array element using thermoelastic expansion in PDMS , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[17]  J. Cannata,et al.  Development of a high-frequency (> 50 MHz) copolymer annular-array, ultrasound transducer , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[18]  M. O'Donnell,et al.  High frequency optoacoustic arrays using etalon detection , 2000, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[19]  F. Alan McDonald,et al.  Practical quantitative theory of photoacoustic pulse generation , 1989 .

[20]  R. J. von Gutfeld,et al.  Laser‐generated MHz elastic waves from metallic‐liquid interfaces , 1979 .