Design and evaluation of an MRI-compatible linear motion stage.

PURPOSE To develop and evaluate a tool for accurate, reproducible, and programmable motion control of imaging phantoms for use in motion sensitive magnetic resonance imaging (MRI) appli cations. METHODS In this paper, the authors introduce a compact linear motion stage that is made of nonmagnetic material and is actuated with an ultrasonic motor. The stage can be positioned at arbitrary positions and orientations inside the scanner bore to move, push, or pull arbitrary phantoms. Using optical trackers, measuring microscopes, and navigators, the accuracy of the stage in motion control was evaluated. Also, the effect of the stage on image signal-to-noise ratio (SNR), artifacts, and B0 field homogeneity was evaluated. RESULTS The error of the stage in reaching fixed positions was 0.025 ± 0.021 mm. In execution of dynamic motion profiles, the worst-case normalized root mean squared error was below 7% (for frequencies below 0.33 Hz). Experiments demonstrated that the stage did not introduce artifacts nor did it degrade the image SNR. The effect of the stage on the B0 field was less than 2 ppm. CONCLUSIONS The results of the experiments indicate that the proposed system is MRI-compatible and can create reliable and reproducible motion that may be used for validation and assessment of motion related MRI applications.

[1]  J. Felmlee,et al.  Adaptive technique for high-definition MR imaging of moving structures. , 1989, Radiology.

[2]  S P M Crijns,et al.  Proof of concept of MRI-guided tracked radiation delivery: tracking one-dimensional motion , 2012, Physics in medicine and biology.

[3]  Ciprian Catana,et al.  MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI , 2012, The Journal of Nuclear Medicine.

[4]  P. Börnert,et al.  Free‐breathing whole‐heart coronary MRA with 3D radial SSFP and self‐navigated image reconstruction , 2005, Magnetic resonance in medicine.

[5]  Holger Schmidt,et al.  Reconstruction-Incorporated Respiratory Motion Correction in Clinical Simultaneous PET/MR Imaging for Oncology Applications , 2015, The Journal of Nuclear Medicine.

[6]  K. Perez Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment , 2014 .

[7]  Zarko Celicanin,et al.  Simultaneous acquisition of image and navigator slices using CAIPIRINHA for 4D MRI , 2015, Magnetic resonance in medicine.

[8]  Titus Kuehne,et al.  Four‐dimensional velocity‐encoded magnetic resonance imaging improves blood flow quantification in patients with complex accelerated flow , 2013, Journal of magnetic resonance imaging : JMRI.

[9]  Jan J W Lagendijk,et al.  Navigators for motion detection during real-time MRI-guided radiotherapy , 2012, Physics in medicine and biology.

[10]  A. Patriciu,et al.  A New Type of Motor: Pneumatic Step Motor , 2007, IEEE/ASME Transactions on Mechatronics.

[11]  Paul Keall,et al.  Investigating the Feasibility of Rapid MRI for Image-Guided Motion Management in Lung Cancer Radiotherapy , 2014, BioMed research international.

[12]  Fang-Fang Yin,et al.  Four dimensional magnetic resonance imaging with retrospective k-space reordering: a feasibility study. , 2015, Medical physics.

[13]  Maria Drangova,et al.  Method for B0 off‐resonance mapping by non‐iterative correction of phase‐errors (B0‐NICE) , 2015, Magnetic resonance in medicine.

[14]  Markus Henningsson,et al.  Prospective respiratory motion correction for coronary MR angiography using a 2D image navigator , 2013, Magnetic resonance in medicine.

[15]  Michael Lustig,et al.  Nonrigid motion correction in 3D using autofocusing withlocalized linear translations , 2012, Magnetic resonance in medicine.

[16]  J. Lagendijk,et al.  Contour propagation in MRI-guided radiotherapy treatment of cervical cancer: the accuracy of rigid, non-rigid and semi-automatic registrations , 2009, Physics in medicine and biology.

[17]  M Drangova,et al.  Physiologic motion phantom for MRI applications , 1996, Journal of magnetic resonance imaging : JMRI.

[18]  C Damianou,et al.  Review of MRI positioning devices for guiding focused ultrasound systems , 2015, The international journal of medical robotics + computer assisted surgery : MRCAS.

[19]  Riccardo Secoli,et al.  A low-cost, high-field-strength magnetic resonance imaging–compatible actuator , 2015, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[20]  Zion Tsz Ho Tse,et al.  An MR-Conditional High-Torque Pneumatic Stepper Motor for MRI-Guided and Robot-Assisted Intervention , 2014, Annals of Biomedical Engineering.

[21]  Zarko Celicanin,et al.  Real‐time method for motion‐compensated MR thermometry and MRgHIFU treatment in abdominal organs , 2014, Magnetic resonance in medicine.

[22]  Rajiv Chopra,et al.  An MRI-compatible system for focused ultrasound experiments in small animal models. , 2009, Medical physics.

[23]  Debiao Li,et al.  Geometric validation of self-gating k-space-sorted 4D-MRI vs 4D-CT using a respiratory motion phantom. , 2015, Medical physics.

[24]  Michael E Casey,et al.  Motion Correction Strategies for Integrated PET/MR , 2015, The Journal of Nuclear Medicine.

[25]  Armando Manduca,et al.  Magnetic resonance elastography of the lung parenchyma in an in situ porcine model with a noninvasive mechanical driver: Correlation of shear stiffness with trans‐respiratory system pressures , 2012, Magnetic resonance in medicine.

[26]  Oliver Speck,et al.  Prospective motion correction in brain imaging: A review , 2013, Magnetic resonance in medicine.

[27]  K. Hynynen,et al.  The targeting accuracy of a preclinical MRI-guided focused ultrasound system. , 2014, Medical physics.

[28]  Himanshu Bhat,et al.  Whole‐heart coronary MRA with 100% respiratory gating efficiency: Self‐navigated three‐dimensional retrospective image‐based motion correction (TRIM) , 2014, Magnetic resonance in medicine.

[29]  Thomas Elgeti,et al.  Magnetic Resonance Elastography of the Heart , 2014, Current Cardiovascular Imaging Reports.

[30]  Khader M Hasan,et al.  Volumetric navigators for real‐time motion correction in diffusion tensor imaging , 2012, Magnetic resonance in medicine.

[31]  Seyed Farokh Atashzar,et al.  Robust Motion Control of Ultrasonic Motors Under Temperature Disturbance , 2016, IEEE Transactions on Industrial Electronics.

[32]  Vivek Muthurangu,et al.  Self‐navigated tissue phase mapping using a golden‐angle spiral acquisition—proof of concept in patients with pulmonary hypertension , 2014, Magnetic resonance in medicine.

[33]  Ciprian Catana,et al.  Motion correction options in PET/MRI. , 2015, Seminars in nuclear medicine.

[34]  Curtis L. Johnson,et al.  Magnetic resonance elastography of the brain using multishot spiral readouts with self‐navigated motion correction , 2013, Magnetic resonance in medicine.

[35]  Jan J W Lagendijk,et al.  MR guidance in radiotherapy , 2014, Physics in medicine and biology.

[36]  Matthias Günther,et al.  Ultrasound‐guided MRI: Preliminary results using a motion phantom , 2004, Magnetic resonance in medicine.

[37]  Paul Keall,et al.  Dynamic keyhole: a novel method to improve MR images in the presence of respiratory motion for real-time MRI. , 2014, Medical physics.

[38]  Tomio Inoue,et al.  Deep-inspiration breath-hold PET/CT versus free breathing PET/CT and respiratory gating PET for reference: evaluation in 95 patients with lung cancer , 2011, Annals of nuclear medicine.

[39]  Steffen Ringgaard,et al.  Three-dimensional liver motion tracking using real-time two-dimensional MRI. , 2014, Medical physics.

[40]  M. L. Wood,et al.  MR image artifacts from periodic motion. , 1985, Medical physics.

[41]  Xiaoyi Jiang,et al.  A Dynamic Thorax Phantom for the Assessment of Cardiac and Respiratory Motion Correction in PET/MRI: A Preliminary Evaluation. , 2013 .

[42]  Maria Drangova,et al.  Rapid six‐degree‐of‐freedom motion detection using prerotated baseline spherical navigator echoes , 2011, Magnetic resonance in medicine.