Evaluation of accuracy in implant site preparation performed in single- or multi-step drilling procedures
暂无分享,去创建一个
Nils-Claudius Gellrich | Martin Rücker | Nadine Marheineke | Uta Scherer | Constantin von See | Björn Rahlf | Marcus Stoetzer | N. Gellrich | M. Rücker | U. Scherer | M. Stoetzer | C. See | B. Rahlf | Nadine Marheineke
[1] Troy MacAvelia,et al. Force and torque modelling of drilling simulation for orthopaedic surgery , 2014, Computer methods in biomechanics and biomedical engineering.
[2] Marcus Abboud,et al. Multistepped Drill Design for Single-Stage Implant Site Preparation: Experimental Study in Type 2 Bone. , 2015, Clinical implant dentistry and related research.
[3] Troy MacAvelia,et al. Biomechanical measurements of surgical drilling force and torque in human versus artificial femurs. , 2012, Journal of biomechanical engineering.
[4] S. Szmukler‐Moncler,et al. Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature. , 1998, Journal of biomedical materials research.
[5] S. Iyer,et al. Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part II: Relationship between drill speed and healing. , 1997, The International journal of prosthodontics.
[6] H. Alghamdi,et al. Undersized implant site preparation to enhance primary implant stability in poor bone density: a prospective clinical study. , 2011, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.
[7] J E Zöller,et al. Possibilities and limitations of implant placement by virtual planning data and surgical guide templates. , 2012, International journal of computerized dentistry.
[8] M. Zwahlen,et al. A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry. , 2009, Clinical oral implants research.
[9] S. Taschieri,et al. Temperature Changes in Cortical Bone after Implant Site Preparation Using a Single Bur versus Multiple Drilling Steps: An In Vitro Investigation. , 2015, Clinical implant dentistry and related research.
[10] Bjarni E Pjetursson,et al. A systematic review of the survival and complication rates of resin-bonded bridges after an observation period of at least 5 years , 2008, BDJ.
[11] Brisman Dl,et al. The effect of speed, pressure, and time on bone temperature during the drilling of implant sites. , 1996 .
[12] Filip Schutyser,et al. A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study. , 2005, Clinical implant dentistry and related research.
[13] P. Coelho,et al. Influence of implant shape, surface morphology, surgical technique and bone quality on the primary stability of dental implants. , 2012, Journal of the mechanical behavior of biomedical materials.
[14] A. Ekestubbe,et al. Clinical outcome of Brånemark System implants of various diameters: a retrospective study. , 2002, The International journal of oral & maxillofacial implants.
[15] Hai-Yang Yu,et al. Micromotions and combined damages at the dental implant/bone interface , 2012, International Journal of Oral Science.
[16] G. Schiroli,et al. Accuracy of computer-aided oral implant surgery: a clinical and radiographic study. , 2009, The International journal of oral & maxillofacial implants.
[17] A. Fuchsberger. [Damaging temperature during the machining of bone]. , 1988, Unfallchirurgie.
[18] Volkan Arısan,et al. Accuracy of two stereolithographic guide systems for computer-aided implant placement: a computed tomography-based clinical comparative study. , 2010, Journal of periodontology.
[19] Vasanthi V. Swami,et al. Current trends to measure implant stability , 2016, Journal of Indian Prosthodontic Society.
[20] Jean Loup Coudert,et al. Reliability of preoperative planning of an image-guided system for oral implant placement based on 3-dimensional images: an in vivo study. , 2003, The International journal of oral & maxillofacial implants.
[21] D. F. James,et al. Drilling in bone: modeling heat generation and temperature distribution. , 2003, Journal of biomechanical engineering.
[22] J. Jansen,et al. In vitro osteogenic potential of bone debris resulting from placement of titanium screw-type implants. , 2008, Clinical oral implants research.
[23] Georg Eggers,et al. Accuracy of image-guided implantology. , 2005, Clinical oral implants research.
[24] R. K. Han,et al. Why guided when freehand is easier, quicker, and less costly? , 2014, The Journal of oral implantology.
[25] M. Swain,et al. Descriptive study of the longevity of dental implant surgery drills. , 2011, Clinical implant dentistry and related research.
[26] J. Jansen,et al. Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study. , 2010, Clinical oral implants research.
[27] Scott E Bulloch,et al. Comparison of heat generation between internally guided (cannulated) single drill and traditional sequential drilling with and without a drill guide for dental implants. , 2012, The International journal of oral & maxillofacial implants.
[28] Predrag Sukovic,et al. Accuracy of implant placement with a stereolithographic surgical guide. , 2003, The International journal of oral & maxillofacial implants.
[29] Han-Joo Lee,et al. The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: a study of drill durability. , 2004, The International journal of oral & maxillofacial implants.
[30] M. Janal,et al. The effect of implant diameter on osseointegration utilizing simplified drilling protocols. , 2014, Clinical oral implants research.
[31] S. Barone,et al. Biomechanics of the press-fit phenomenon in dental implantology: an image-based finite element analysis , 2012, Head & Face Medicine.
[32] S. Iyer,et al. Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part I: Relationship between drill speed and heat production. , 1997, The International journal of prosthodontics.
[33] G. Orive,et al. Efficacy of biologically guided implant site preparation to obtain adequate primary implant stability. , 2015, Annals of anatomy = Anatomischer Anzeiger : official organ of the Anatomische Gesellschaft.
[34] J. D'haese,et al. Accuracy and complications using computer-designed stereolithographic surgical guides for oral rehabilitation by means of dental implants: a review of the literature. , 2012, Clinical implant dentistry and related research.
[35] M. Janal,et al. The Effect of Simplifying Dental Implant Drilling Sequence on Osseointegration: An Experimental Study in Dogs , 2013, International journal of biomaterials.
[36] P. Coelho,et al. Biomechanical evaluation of undersized drilling on implant biomechanical stability at early implantation times. , 2013, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.
[37] S. Gehrke. Evaluation of the Cortical Bone Reaction Around of Implants Using a Single-Use Final Drill: A Histologic Study , 2015, The Journal of craniofacial surgery.
[38] M. B. Abouzgia,et al. Effect of drill speed on bone temperature. , 1996, International journal of oral and maxillofacial surgery.
[39] A. Fuchsberger. Die schädigende temperatur bei der spanendem knochenbearbeitung , 1988, Unfallchirurgie.
[40] S. Heo,et al. Effects of anodized oxidation or turned implants on bone healing after using conventional drilling or trabecular compaction technique: histomorphometric analysis and RFA. , 2006, Clinical oral implants research.
[41] Laura W. Bancroft,et al. Bone graft materials and synthetic substitutes. , 2006, Radiologic clinics of North America.
[42] L. Sennerby. Dental implants: matters of course and controversies. , 2008, Periodontology 2000.
[43] Seung-Beom Kye,et al. Effect of implant drill design on the particle size of the bone collected during osteotomy. , 2010, International journal of oral and maxillofacial surgery.
[44] Fritz Klocke,et al. Influence of bone density and implant drill diameter on the resulting axial force and temperature development in implant burs and artificial bone: an in vitro study , 2016, Oral and Maxillofacial Surgery.
[45] A. R.,et al. Review of literature , 1951, American Potato Journal.
[46] Toma Udiljak,et al. Thermal osteonecrosis and bone drilling parameters revisited , 2007, Archives of Orthopaedic and Trauma Surgery.
[47] Edwin A McGlumphy,et al. Heat production by 3 implant drill systems after repeated drilling and sterilization. , 2006, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.
[48] P. Büchler,et al. Quantifying the influence of bone density and thickness on resonance frequency analysis: an in vitro study of biomechanical test materials. , 2009, The International journal of oral & maxillofacial implants.
[49] I. Garcia,et al. Evaluation of bone heating, drill deformation, and drill roughness after implant osteotomy: guided surgery and classic drilling procedure. , 2014, The International journal of oral & maxillofacial implants.
[50] L. Bancroft,et al. Imaging characteristics of bone graft materials. , 2006, Radiographics : a review publication of the Radiological Society of North America, Inc.
[51] P. Coelho,et al. The combined effects of undersized drilling and implant macrogeometry on bone healing around dental implants: an experimental study. , 2014, International journal of oral and maxillofacial surgery.
[52] S. Taschieri,et al. Implant survival after preparation of the implant site using a single bur: a case series. , 2015, Clinical implant dentistry and related research.
[53] G. Haïat,et al. Effects of biomechanical properties of the bone-implant interface on dental implant stability: from in silico approaches to the patient's mouth. , 2014, Annual review of biomedical engineering.
[54] A. Vaziri,et al. Biomechanics and mechanobiology of trabecular bone: a review. , 2015, Journal of biomechanical engineering.
[55] Lars Sennerby,et al. Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications. , 2008, Periodontology 2000.
[56] CLINICaL wINdow,et al. Template-guided vs . non-guided drilling in site preparation of dental implants , 2015 .
[57] M. Peñarrocha,et al. Pain and inflammation after periapical surgery in 60 patients. , 2006, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.
[58] R. Adell,et al. Temperatures during drilling for the placement of implants using the osseointegration technique. , 1986, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.
[59] E. Keleşoğlu,et al. Effects of irrigation temperature on heat control in vitro at different drilling depths. , 2009, Clinical oral implants research.