Alpha image reconstruction (AIR): a new iterative CT image reconstruction approach using voxel-wise alpha blending.

PURPOSE Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. Among vendors and researchers, however, there is no consensus of how to best achieve these aims. The general approach is to incorporate a priori knowledge into iterative image reconstruction, for example, by adding additional constraints to the cost function, which penalize variations between neighboring voxels. However, this approach to regularization in general poses a resolution noise trade-off because the stronger the regularization, and thus the noise reduction, the stronger the loss of spatial resolution and thus loss of anatomical detail. The authors propose a method which tries to improve this trade-off. The proposed reconstruction algorithm is called alpha image reconstruction (AIR). One starts with generating basis images, which emphasize certain desired image properties, like high resolution or low noise. The AIR algorithm reconstructs voxel-specific weighting coefficients that are applied to combine the basis images. By combining the desired properties of each basis image, one can generate an image with lower noise and maintained high contrast resolution thus improving the resolution noise trade-off. METHODS All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and low contrast disks is simulated. A filtered backprojection (FBP) reconstruction with a Ram-Lak kernel is used as a reference reconstruction. The results of AIR are compared against the FBP results and against a penalized weighted least squares reconstruction which uses total variation as regularization. The simulations are based on the geometry of the Siemens Somatom Definition Flash scanner. To quantitatively assess image quality, the authors analyze line profiles through resolution patterns to define a contrast factor for contrast-resolution plots. Furthermore, the authors calculate the contrast-to-noise ratio with the low contrast disks and the authors compare the agreement of the reconstructions with the ground truth by calculating the normalized cross-correlation and the root-mean-square deviation. To evaluate the clinical performance of the proposed method, the authors reconstruct patient data acquired with a Somatom Definition Flash dual source CT scanner (Siemens Healthcare, Forchheim, Germany). RESULTS The results of the simulation study show that among the compared algorithms AIR achieves the highest resolution and the highest agreement with the ground truth. Compared to the reference FBP reconstruction AIR is able to reduce the relative pixel noise by up to 50% and at the same time achieve a higher resolution by maintaining the edge information from the basis images. These results can be confirmed with the patient data. CONCLUSIONS To evaluate the AIR algorithm simulated and measured patient data of a state-of-the-art clinical CT system were processed. It is shown, that generating CT images through the reconstruction of weighting coefficients has the potential to improve the resolution noise trade-off and thus to improve the dose usage in clinical CT.

[1]  Marc Kachelrieß,et al.  Removing blooming artifacts with binarized deconvolution in cardiac CT , 2014, Medical Imaging.

[2]  Jeffrey A. Fessler,et al.  Edge-preserving tomographic reconstruction with nonlocal regularization , 2002 .

[3]  Marc Kachelrieß,et al.  A new approach to regularized iterative CT image reconstruction , 2014, Medical Imaging.

[4]  M. Kachelriess Iterative Reconstruction Techniques: What do they Mean for Cardiac CT? , 2013, Current Cardiovascular Imaging Reports.

[5]  Luo Ouyang,et al.  Effects of the penalty on the penalized weighted least-squares image reconstruction for low-dose CBCT. , 2011, Physics in medicine and biology.

[6]  R Proksa,et al.  Noise and resolution in images reconstructed with FBP and OSC algorithms for CT. , 2007, Medical physics.

[7]  M. Persson,et al.  Total variation norm for three-dimensional iterative reconstruction in limited view angle tomography , 2001, Physics in medicine and biology.

[8]  J. Leipsic,et al.  Iterative reconstruction for coronary CT angiography: finding its way , 2012, The International Journal of Cardiovascular Imaging.

[9]  Hugo A Katus,et al.  Reduction of radiation exposure and improvement of image quality with BMI-adapted prospective cardiac computed tomography and iterative reconstruction. , 2012, European journal of radiology.

[10]  Sebastian Feuerlein,et al.  New iterative reconstruction techniques for cardiovascular computed tomography: how do they work, and what are the advantages and disadvantages? , 2011, Journal of cardiovascular computed tomography.

[11]  Ken D. Sauer,et al.  A unified approach to statistical tomography using coordinate descent optimization , 1996, IEEE Trans. Image Process..

[12]  Fabian Bamberg,et al.  CT evaluation of coronary artery stents with iterative image reconstruction: improvements in image quality and potential for radiation dose reduction , 2012, European Radiology.

[13]  Jean-Baptiste Thibault,et al.  A three-dimensional statistical approach to improved image quality for multislice helical CT. , 2007, Medical physics.

[14]  Rainer Raupach,et al.  Adaptive iterative reconstruction , 2011, Medical Imaging.

[15]  L. Xing,et al.  Iterative image reconstruction for CBCT using edge-preserving prior. , 2008, Medical physics.

[16]  P. Joseph An Improved Algorithm for Reprojecting Rays through Pixel Images , 1983, IEEE Transactions on Medical Imaging.

[17]  Arnold M. R. Schilham,et al.  Iterative reconstruction techniques for computed tomography Part 1: Technical principles , 2013, European Radiology.

[18]  Udo Hoffmann,et al.  Coronary artery plaques: cardiac CT with model-based and adaptive-statistical iterative reconstruction technique. , 2012, European journal of radiology.

[19]  S. Achenbach,et al.  Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience , 2011, The International Journal of Cardiovascular Imaging.

[20]  G. N. Ramachandran,et al.  Three-dimensional reconstruction from radiographs and electron micrographs: application of convolutions instead of Fourier transforms. , 1971, Proceedings of the National Academy of Sciences of the United States of America.

[21]  P. Joseph An Improved Algorithm for Reprojecting Rays through Pixel Images , 1982 .

[22]  James K Min,et al.  Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: the ERASIR study. , 2010, AJR. American journal of roentgenology.

[23]  Jie Tang,et al.  Prior image constrained compressed sensing: implementation and performance evaluation. , 2011, Medical physics.

[24]  Gengsheng L Zeng,et al.  Iterative total-variation reconstruction versus weighted filtered-backprojection reconstruction with edge-preserving filtering , 2013, Physics in medicine and biology.

[25]  Synho Do,et al.  A decomposition-based CT reconstruction formulation for reducing blooming artifacts. , 2011, Physics in medicine and biology.

[26]  F. Hermansen,et al.  Noise reduction and convergence of Bayesian algorithms with blobs based on the Huber function and median root prior , 2004, Physics in medicine and biology.